High Quality Bending Section Assembly For Olympus CF-HQ290I Colonoscope

Apple Shopping Event

Hurry and get discounts up to 20% Read more

► Brief Description

The Bending Section Assembly is a highly precise, flexible mechanical component located at the distal end of the insertion tube on the Olympus CF-HQ290I colonoscope. As a critical structural element, it enables the physician to steer and navigate the scope smoothly through the complex, winding anatomy of the large intestine. Because the CF-HQ290I is a flagship high-definition therapeutic endoscope, its bending section is engineered to be incredibly compact while housing an intricate network of advanced imaging, illumination, and therapeutic channels.

► Features

  • Multi-Directional Angulation (4-Way Deflection):The primary function of the assembly is to provide smooth 4-way angulation (Up/Down/Left/Right). This allows the endoscopist to maneuver around the sharp bends of the sigmoid colon and the splenic/hepatic flexures with minimal patient discomfort.
  • Structural Support & Channel Guidance:The internal segment rings act as a protective skeleton. They house and shield vital internal components—such as the high-definition CCD/CMOS video wires, light guide bundles, instrument (biopsy) channel, and air/water feeding tubes—preventing them from kinking or crushing during bending.
  • Dynamic Flexibility and Shape Retention:Engineered to balance rigidity and flexibility. It provides enough tactile feedback and column strength for the scope to be pushed forward without looping, yet remains flexible enough to retroflex (bend backward) in the rectum for thorough inspection.

► Specification

Brand Olympus
Model CF-HQ290I
Condition Brand new
Series Bending Section Assembly
Outer Diameter (OD) Approx. 11.6 mm
Instrument Channel ID 3.7 mm
Total Assembly Length Approx. 107.6 mm
Up / Down Angulation 180° / 180°
Right / Left Angulation 160° / 160°
Material Medical-grade stainless steel
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Warranty Policy

All new aftermarket parts come with a 1-Year warranty. Quality is the first thing we consider. Check out our Warranty Assistance for more details.

Shipping Policy

All expedited shipping so you can get your medical machine back in action, fast. Check out our Shipping Policy for more details.

Easy Return Policy

We prioritize your satisfaction. If your order doesn't meet your expectations within 90 days, you may be eligible for a refund. See our Easy Return Policy for details.

Description

Bending Section Assembly For Olympus CF-HQ290I Colonoscope

c833b2be01003ec27917d7e3bd97a36e 9f5309384a3195e14f2b2943339871f8 a6438ddcc6f6f07a67a5c93d2ef219cc 066a39b4eba2b551fc03a7d4fea5c1c4
► Brief Description

The Bending Section Assembly is a highly precise, flexible mechanical component located at the distal end of the insertion tube on the Olympus CF-HQ290I colonoscope. As a critical structural element, it enables the physician to steer and navigate the scope smoothly through the complex, winding anatomy of the large intestine. Because the CF-HQ290I is a flagship high-definition therapeutic endoscope, its bending section is engineered to be incredibly compact while housing an intricate network of advanced imaging, illumination, and therapeutic channels.

► Features

  • Multi-Directional Angulation (4-Way Deflection):The primary function of the assembly is to provide smooth 4-way angulation (Up/Down/Left/Right). This allows the endoscopist to maneuver around the sharp bends of the sigmoid colon and the splenic/hepatic flexures with minimal patient discomfort.
  • Structural Support & Channel Guidance:The internal segment rings act as a protective skeleton. They house and shield vital internal components—such as the high-definition CCD/CMOS video wires, light guide bundles, instrument (biopsy) channel, and air/water feeding tubes—preventing them from kinking or crushing during bending.
  • Dynamic Flexibility and Shape Retention:Engineered to balance rigidity and flexibility. It provides enough tactile feedback and column strength for the scope to be pushed forward without looping, yet remains flexible enough to retroflex (bend backward) in the rectum for thorough inspection.

► Specification

Brand Olympus
Model CF-HQ290I
Condition Brand new
Series Bending Section Assembly
Outer Diameter (OD) Approx. 11.6 mm
Instrument Channel ID 3.7 mm
Total Assembly Length Approx. 107.6 mm
Up / Down Angulation 180° / 180°
Right / Left Angulation 160° / 160°
Material Medical-grade stainless steel
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

►FAQ

What are the most common signs that the bending section assembly needs to be replaced?

The most frequent indicators of a failing or worn bending section include:

  • Diminished Angulation: The scope cannot reach its maximum bending angles (180° Up/Down, 160° Left/Right).

  • Play or Slack in the Knobs: The control knobs on the control section feel loose, or there is a delay before the tip actually moves.

  • Sticky or Heavy Movement: The articulation feels rough, stiff, or requires excessive force to turn.

  • Physical Damage: Visible tears, stretching, or wrinkling of the outer bending rubber, or a “snakelike” warping of the internal mesh.

► More service

Spare parts for flexible endoscope: insert tube, wires,helix tube,coil pipe,C-cover,glass for CCD,glass for light bundle,objective lens for CCD,drive board for CCD,light guide tube, light bundle,forcep tube, bending section, rubber, air&water tube, CCD, light source, processor, monitor, etc.

About Us

CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.

Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.
►What we can do

e103f202af370e20fed443c4c46ca11

Product details

In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.

Product details

In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.

Description

Bending Section Assembly For Olympus CF-HQ290I Colonoscope

c833b2be01003ec27917d7e3bd97a36e 9f5309384a3195e14f2b2943339871f8 a6438ddcc6f6f07a67a5c93d2ef219cc 066a39b4eba2b551fc03a7d4fea5c1c4
► Brief Description

The Bending Section Assembly is a highly precise, flexible mechanical component located at the distal end of the insertion tube on the Olympus CF-HQ290I colonoscope. As a critical structural element, it enables the physician to steer and navigate the scope smoothly through the complex, winding anatomy of the large intestine. Because the CF-HQ290I is a flagship high-definition therapeutic endoscope, its bending section is engineered to be incredibly compact while housing an intricate network of advanced imaging, illumination, and therapeutic channels.

► Features

  • Multi-Directional Angulation (4-Way Deflection):The primary function of the assembly is to provide smooth 4-way angulation (Up/Down/Left/Right). This allows the endoscopist to maneuver around the sharp bends of the sigmoid colon and the splenic/hepatic flexures with minimal patient discomfort.
  • Structural Support & Channel Guidance:The internal segment rings act as a protective skeleton. They house and shield vital internal components—such as the high-definition CCD/CMOS video wires, light guide bundles, instrument (biopsy) channel, and air/water feeding tubes—preventing them from kinking or crushing during bending.
  • Dynamic Flexibility and Shape Retention:Engineered to balance rigidity and flexibility. It provides enough tactile feedback and column strength for the scope to be pushed forward without looping, yet remains flexible enough to retroflex (bend backward) in the rectum for thorough inspection.

► Specification

Brand Olympus
Model CF-HQ290I
Condition Brand new
Series Bending Section Assembly
Outer Diameter (OD) Approx. 11.6 mm
Instrument Channel ID 3.7 mm
Total Assembly Length Approx. 107.6 mm
Up / Down Angulation 180° / 180°
Right / Left Angulation 160° / 160°
Material Medical-grade stainless steel
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

►FAQ

What are the most common signs that the bending section assembly needs to be replaced?

The most frequent indicators of a failing or worn bending section include:

  • Diminished Angulation: The scope cannot reach its maximum bending angles (180° Up/Down, 160° Left/Right).

  • Play or Slack in the Knobs: The control knobs on the control section feel loose, or there is a delay before the tip actually moves.

  • Sticky or Heavy Movement: The articulation feels rough, stiff, or requires excessive force to turn.

  • Physical Damage: Visible tears, stretching, or wrinkling of the outer bending rubber, or a “snakelike” warping of the internal mesh.

► More service

Spare parts for flexible endoscope: insert tube, wires,helix tube,coil pipe,C-cover,glass for CCD,glass for light bundle,objective lens for CCD,drive board for CCD,light guide tube, light bundle,forcep tube, bending section, rubber, air&water tube, CCD, light source, processor, monitor, etc.

About Us

CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.

Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.
►What we can do

e103f202af370e20fed443c4c46ca11

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “High Quality Bending Section Assembly For Olympus CF-HQ290I Colonoscope”

Your email address will not be published. Required fields are marked *

Fix Once Right, Save Replacement Costs

Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.

However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.

Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.

If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!