The KARL STORZ HAMOU ENDOMAT (Model 26331020) irrigation/suction tubing set (commonly referred to as distension tubing or pump cassette/tubing set) is a dedicated fluid-delivery consumable designed for hysteroscopic distension and endoscopic irrigation. Engineered for seamless integration with the HAMOU ENDOMAT SCB roller pump unit, it ensures controlled, continuous fluid flow and accurate intrauterine pressure monitoring during diagnostic and operative hysteroscopy.
►Features
- Controlled Fluid Delivery: Transmits irrigation/distension media (e.g., normal saline, glycine, or sorbitol/mannitol depending on energy modality) smoothly from the fluid bag to the hysteroscope inflow channel via peristaltic roller action.
- Real-Time Pressure Monitoring: Relays hydraulic pressure back to the
26331020control unit so the pump can automatically regulate flow rate and maintain target intrauterine distension pressure (typically adjustable up to 150–200 mmHg depending on system settings). - Overpressure Safety Protection: Enables immediate pump pause or pressure-relief response if intrauterine pressure exceeds preset safety thresholds, reducing the risk of excessive fluid intravasation.
- System Recognition & Seal Integrity: Features a keyed cassette/collar or sensor interface that aligns securely with the pump housing to prevent slippage, air entrainment, or fluid leakage during procedures.
► Specification
| Brand | KARL STORZ |
| Model | 26331020 |
| Condition | Brand new |
| Series | Irrigation / Distension Tubing Set |
| Tubing Material | DEHP-free medical-grade PVC and silicone |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
All new aftermarket parts come with a 1-Year warranty. Quality is the first thing we consider. Check out our Warranty Assistance for more details.
All expedited shipping so you can get your medical machine back in action, fast. Check out our Shipping Policy for more details.
We prioritize your satisfaction. If your order doesn't meet your expectations within 90 days, you may be eligible for a refund. See our Easy Return Policy for details.
Description
Brand New Irrigation / Distension Tubing Set For KARL STORZ 26331020 HAMOU ENDOMAT

► Brief Description
The KARL STORZ HAMOU ENDOMAT (Model 26331020) irrigation/suction tubing set (commonly referred to as distension tubing or pump cassette/tubing set) is a dedicated fluid-delivery consumable designed for hysteroscopic distension and endoscopic irrigation. Engineered for seamless integration with the HAMOU ENDOMAT SCB roller pump unit, it ensures controlled, continuous fluid flow and accurate intrauterine pressure monitoring during diagnostic and operative hysteroscopy.
►Features
- Controlled Fluid Delivery: Transmits irrigation/distension media (e.g., normal saline, glycine, or sorbitol/mannitol depending on energy modality) smoothly from the fluid bag to the hysteroscope inflow channel via peristaltic roller action.
- Real-Time Pressure Monitoring: Relays hydraulic pressure back to the
26331020control unit so the pump can automatically regulate flow rate and maintain target intrauterine distension pressure (typically adjustable up to 150–200 mmHg depending on system settings). - Overpressure Safety Protection: Enables immediate pump pause or pressure-relief response if intrauterine pressure exceeds preset safety thresholds, reducing the risk of excessive fluid intravasation.
- System Recognition & Seal Integrity: Features a keyed cassette/collar or sensor interface that aligns securely with the pump housing to prevent slippage, air entrainment, or fluid leakage during procedures.
► Specification
| Brand | KARL STORZ |
| Model | 26331020 |
| Condition | Brand new |
| Series | Irrigation / Distension Tubing Set |
| Tubing Material | DEHP-free medical-grade PVC and silicone |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
►FAQ
What is the difference between single-spike and dual-spike tubing sets?A:
-
Single-spike tubing sets connect to one fluid bag at a time and are suitable for shorter diagnostic or minor operative procedures.
-
Dual-spike (Y-type) tubing sets allow two irrigation bags to be hung simultaneously with integrated pinch clamps, enabling uninterrupted fluid switching during longer operative hysteroscopy procedures without introducing air into the line.
Why does the pump fail to deliver fluid or show zero flow even though the rollers are turning?A: Common causes include:
-
Unopened clamps or air vents: Verify that the roller clamp on the tubing and the air-venting cap on the fluid bag spike are open.
-
Misaligned pump segment: The silicone tubing section may have slipped out of the roller track; release the rollers and re-seat the collar.
-
Kinked line or empty fluid bag: Inspect the entire path from the fluid bag to the hysteroscope inflow stopcock.
Why is the unit displaying abnormally high irrigation pressure or triggering an overpressure alarm?A:
-
Closed inflow stopcock: Check that the inflow valve on the hysteroscope sheath is fully open.
-
Blocked outflow or debris: Tissue fragments or blood clots in a narrow sheath channel can restrict flow and spike line pressure.
-
Pressure sensor issue: Ensure the pressure-sensing dome/membrane is properly seated and free of fluid/moisture on the sensor side.
-
Hydrostatic height offset: Confirm the fluid bag is hung at the standard recommended height relative to the pump and patient level.
► More service
Spare parts for Rigid Endoscope:
Rod lens,Objective lens,Rings,Glass,Eyepiece & Cover,Outer tube & Inner tube,Fiber,etc.
► About Us
CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.
Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.
► What we can do

Product details
In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.
Product details
In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.
Description
Brand New Irrigation / Distension Tubing Set For KARL STORZ 26331020 HAMOU ENDOMAT

► Brief Description
The KARL STORZ HAMOU ENDOMAT (Model 26331020) irrigation/suction tubing set (commonly referred to as distension tubing or pump cassette/tubing set) is a dedicated fluid-delivery consumable designed for hysteroscopic distension and endoscopic irrigation. Engineered for seamless integration with the HAMOU ENDOMAT SCB roller pump unit, it ensures controlled, continuous fluid flow and accurate intrauterine pressure monitoring during diagnostic and operative hysteroscopy.
►Features
- Controlled Fluid Delivery: Transmits irrigation/distension media (e.g., normal saline, glycine, or sorbitol/mannitol depending on energy modality) smoothly from the fluid bag to the hysteroscope inflow channel via peristaltic roller action.
- Real-Time Pressure Monitoring: Relays hydraulic pressure back to the
26331020control unit so the pump can automatically regulate flow rate and maintain target intrauterine distension pressure (typically adjustable up to 150–200 mmHg depending on system settings). - Overpressure Safety Protection: Enables immediate pump pause or pressure-relief response if intrauterine pressure exceeds preset safety thresholds, reducing the risk of excessive fluid intravasation.
- System Recognition & Seal Integrity: Features a keyed cassette/collar or sensor interface that aligns securely with the pump housing to prevent slippage, air entrainment, or fluid leakage during procedures.
► Specification
| Brand | KARL STORZ |
| Model | 26331020 |
| Condition | Brand new |
| Series | Irrigation / Distension Tubing Set |
| Tubing Material | DEHP-free medical-grade PVC and silicone |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
►FAQ
What is the difference between single-spike and dual-spike tubing sets?A:
-
Single-spike tubing sets connect to one fluid bag at a time and are suitable for shorter diagnostic or minor operative procedures.
-
Dual-spike (Y-type) tubing sets allow two irrigation bags to be hung simultaneously with integrated pinch clamps, enabling uninterrupted fluid switching during longer operative hysteroscopy procedures without introducing air into the line.
Why does the pump fail to deliver fluid or show zero flow even though the rollers are turning?A: Common causes include:
-
Unopened clamps or air vents: Verify that the roller clamp on the tubing and the air-venting cap on the fluid bag spike are open.
-
Misaligned pump segment: The silicone tubing section may have slipped out of the roller track; release the rollers and re-seat the collar.
-
Kinked line or empty fluid bag: Inspect the entire path from the fluid bag to the hysteroscope inflow stopcock.
Why is the unit displaying abnormally high irrigation pressure or triggering an overpressure alarm?A:
-
Closed inflow stopcock: Check that the inflow valve on the hysteroscope sheath is fully open.
-
Blocked outflow or debris: Tissue fragments or blood clots in a narrow sheath channel can restrict flow and spike line pressure.
-
Pressure sensor issue: Ensure the pressure-sensing dome/membrane is properly seated and free of fluid/moisture on the sensor side.
-
Hydrostatic height offset: Confirm the fluid bag is hung at the standard recommended height relative to the pump and patient level.
► More service
Spare parts for Rigid Endoscope:
Rod lens,Objective lens,Rings,Glass,Eyepiece & Cover,Outer tube & Inner tube,Fiber,etc.
► About Us
CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.
Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.
► What we can do

Customer Reviews
Related Products
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!

Reviews
Clear filtersThere are no reviews yet.