KARL STORZ
Product Categories
- Esaote 0
- NEW PRODUCT 5
- Olympus 0
- Parts for Anesthesia 0
- Parts for Camera system 75
- Parts for Defibrillator 0
- Parts for Dynamical System 85
- Parts for Flexible Endoscope 279
- Parts for Monitor 0
- Parts for MRI 0
- Parts for Rigid Endoscope 11
- Parts for Surgical Instrument 45
- Parts for Ultrasound & Probe 85
- Parts for Ventilator 72
- PCR and Centrifuge 8
- Repair Cases 169
- Repair Tools 21
Showing all 10 results
Brand New Cable For KARL STORZ TIPCAM 1S 3D Video Endoscope
$0.00► Brief Description
The TIPCAM 1 S 3D is a video endoscope, meaning the image sensors are located at the endoscope’s tip. The “cable” connecting the image sensors to the camera control unit (CCU) is typically integrated into the main body of the endoscope handle and connects via a proprietary connector to the IMAGE1 Sâ„¢ CCU.
► Features
- Image Data Transmission: Transmits the digital video signal captured by the two CMOS sensors at the tip of the endoscope. Since it’s a 3D scope, it carries two parallel streams of full HD video data.​
- Control Signal Transmission:Â Carries control signals for the camera unit, such as power supply and communication with the CCU (e.g., for switching between 3D and 2D modes, or utilizing S-Technologies like CLARA and CHROMA).
- Mechanical Connection:Â Provides a secure, proprietary electrical and mechanical connection to the IMAGE1 Sâ„¢ CCU (Camera Control Unit), which is essential for processing the 3D images.
► Specification
| Brand | KARL STORZ |
| Model | TIPCAM 1S 3D |
| Condition | Brand new |
| Serise | Video Cable |
| Data Type | Dual-stream Full HD Digital Video Data |
| Connection | Multi-pin connector |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Camera Head Cable For Karl Storz IMAGE1 HD H3 Camera Head
$0.00► Brief Description
The cable for H3Â camera head, as it is a critical, integrated component of the Storz endoscopic imaging platform, responsible for transmitting the HD video and control data.
► Features
- High-Bandwidth Data Transfer​
- Power and Grounding
- Control Signal Relay
- System Communication
- Ergonomics
â–º Specification
| Brand | Karl Storz |
| Model | H3 |
| Condition | Brand new |
| Serise | Camera Head Cable |
| Length (Typical) | 300 cm |
| Signal Transmission | Digital HD Signal |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Camera Head Cable For Richard Wolf 5525 Camera Head
$0.00► Brief Description
The Richard Wolf 5525 Camera Head Cable is typically associated with the ENDOCAM Logic 4K (Camera Head 85525942) or ENDOCAM Logic HD ($85525922/85525923) systems, connecting the camera head to the camera control unit (CCU 5525301).
► Features
- Digital Data Transmission
- Power Supply
- Control Signal Transmission
- Enabling Reprocessing
â–º Specification
| Brand | Richard Wolf |
| Model | 5525 |
| Condition | Brand new |
| Serise | Camera Head Cable |
| Material | High-grade materials |
| Length (Typical) | 3m |
| Durability | Strong flexural bearing capacity, anti-sway pull, high wear resistance |
| Transportation | DHL, FedEx, UPS, etc. |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| In Stock | Yes |
| Price | Accept Negotiation |
Camera Head Cable For STORZ H3-Z Camera Head
$0.00► Brief Description
The “Cable for STORZ H3-Z Camera Head” is not merely a power cord; it is a critical, integrated component of the Karl Storz IMAGE1 HD H3-Z (TH100) Endoscopic Camera System, responsible for transmitting the high-definition video signal and control data.
► Features
- High-Definition Video Link​
- Control Signal Transmission
- Power Supply
- Data Communication
- Ergonomics & Flexibility
â–º Specification
| Brand | STORZ |
| Model | H3-Z |
| Condition | Brand new |
| Serise | Camera Head Cable |
| Length (Typical) | 300 cm |
| Signal Transmission | Digital HD Signal |
| Material / Durability | Medical-grade Polymer |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
High Quality CCD For KARL STORZ H3 Camera Head
$0.00► Brief Description
The function of the CCD (Charge-Coupled Device) component within the STORZ H3 Camera Head is fundamental to its operation.The CCD acts as the image sensor, converting the light captured by the endoscope/lens into an electrical signal that can be processed and displayed as an image.
► Features
- Light-to-Signal Conversion (Image Sensing)
- Color Separation and Fidelity
- High Resolution Image Generation
- Low Noise and High Sensitivity
- Progressive Scanning
â–º Specification
| Brand | KARL STORZ |
| Model | H3 |
| Condition | Working in Good Condition |
| Series | Camera CCD |
| Sensor Type | 3-Chip Technology |
| Resolution | Full High Definition |
| Frame Rate | 50/60 Hz |
| Optical System | Parfocal Zoom Lens |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
High Quality CCD For KARL STORZ H3-Z Camera Head
$0.00► Brief Description
The KARL STORZ H3-Z camera head is a cornerstone component of the IMAGE1 HD endoscopy system. It utilizes advanced sensor technology to deliver high-resolution images for surgical procedures.
► Features
- High-Resolution Image Capture
- Parfocal Optical Zoom Control
- Progressive Scanning
- Real-Time Image Transmission
- Automatic Light/Exposure Management
- Programmable Remote Control
- Accurate Color Reproduction
â–º Specification
| Brand | KARL STORZ |
| Model | H3-Z |
| Condition | Working in Good Condition |
| Series | Camera CCD |
| Sensor Type | 3-Chip Technology |
| Resolution | Full High Definition |
| Aspect Ratio | 16:9 |
| Optical System | Parfocal Zoom Lens |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
High Quality CCD For KARL STORZ IMAGE1 Sâ„¢ H3-Z FI TH102 Camera Head
$0.00► Brief Description
The STORZ TH102 camera head utilizes 3-Chip CCD technology to achieve its high-performance imaging capabilities.The 3-Chip CCD in the STORZ TH102 is the highly sensitive, high-resolution sensor package responsible for capturing and defining the sharp, color-accurate, and stable Full HD video stream.
► Features
- Light Conversion:Â The primary function is to convert incident photons (light), transmitted through the endoscope’s lens system, into an electrical charge packet proportional to the light’s intensity.
- Charge Transfer:Â The CCD architecture allows the accumulated charge to be efficiently transferred, pixel by pixel, to the output amplifier for digitization and processing.
- True Color Separation:Â Because it is a 3-Chip system, a prism inside the camera head splits the light into its primary color components (Red, Green, Blue) before reaching the CCDs. Each chip captures only one color
- High Definition Capture: The dense arrangement of the CCD pixels allows the camera to record the full 1920 *1080 data required for a Full HD video signal.
- LFlicker-Free Output:Â The Progressive Scan function of the CCD ensures a stable, clean video feed by capturing the image in a single pass, which is essential for reducing eye fatigue and improving precision during long surgical procedures.
► Specification
| Brand | KARL STORZ |
| Model | TH102 |
| Condition | Working in Good Condition |
| Series | Camera CCD |
| Sensor Type | 3-Chip Technology |
| Color Depth | High Fidelity |
| Light Sensitivity | High |
| Scanning Method | Progressive Scan |
| Resolution | Full High Definition |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
KARL STORZ 11278A1 ureteroscope for repair
$0.00► Brief Description
Fault:
1) Image spotted with partially black point, image bundle aged
2) Light bundle partially wire broken
3) Insert tube aged
4) Biopsy tube abrasion and leakage
5) Wires and coil pipe abrasion
Solution:
Replace HD image bundle, light bundle, insert tube, wires, coil pipe and rubber.
â–ºProblem & Solutoin
| Brand | KARL STORZ |
| Model | 11278A1 |
| Fault | 1) Image spotted with partially black point, image bundle aged 2) Light bundle partially wire broken 3) Insert tube aged 4) Biopsy tube abrasion and leakage 5) Wires and coil pipe abrasion |
| Solution | Replace HD image bundle, light bundle, insert tube, wires, coil pipe and rubber. |
► Common issues with 11278A1 ureteroscope
- Image/Optical System Problems
- Sheath/Working Element Issues
- Light Transmission Problems
- Channel Obstructions
- Overall Integrity/Physical Damage
Karl Storz 27005BA endoscope for repair
$0.00► Brief Description
Fault:
1. No image.
2. Fiber abrasion.
3. Rod lens broken and cracked.
4. Objective lens broken and dirty.
5. Eyepiece cover broken.
Solution:
1. Replace rod lens.
2. Replace inner tube.
3. Replace outer tube.
4. Replace objective lens group.
5. Clean the eyepiece.
6. Replace fiber.
7. Replace eyepiece cover.
8. Clean and install the optical path, check the image.
9. Seal with endoscope and test.
â–ºProblem & Solutoin
| Brand | Karl Storz |
| Model | 27005BA |
| Fault | 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. |
| Solution | 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Replace eyepiece cover. 8. Clean and install the optical path, check the image. 9. Seal with endoscope and test. |
► Common issues with 27005BA endoscope
- Blurry or unclear image
- Static or “snow” on the image
- Anomalies in image formation
- Cable damage (cut/crack)
- Coupler damage
- Connector pin damage
- Fluid invasion
- Fiber optic damage
- Wear and Tear
KARL STORZ 8403HX Video Laryngoscope Blade
$0.00► Brief Description
The KARL STORZ 8403HX is a C-MAC® Video Laryngoscope HD D-Blade. It is part of the C-MAC HD series, designed for optimized visualization during intubation, particularly in adults and for difficult airways.
► Features
- HD Visualization:Â Provides High-Definition (HD) video visualization of the intubation process, improving clarity and detail
- Hyperangulated D-Blade:Â The blade’s hyperangulated design (D-Blade) is specifically suited for difficult intubations where direct laryngoscopy may be challenging.
- C-MAC® System Compatibility: It offers plug & play functionality with the universal KARL STORZ C-MAC® system interface, allowing connection to the C-MAC monitor.
- Integrated Camera:Â Contains a stainless steel camera and components for reliable imaging.
- Lightweight and Robust Design:Â Features a titanium handle for a lightweight yet robust construction.
- Multifunctional Button:Â Includes a button for documentation (image capture or video recording) directly from the device (when connected to a C-MAC system with recording capability).
- Reprocessing:Â Designed with a high IP protection class (IPX8) for safe reprocessing (cleaning, disinfection, and sterilization).
► Specification
| Brand | KARL STORZ |
| Model | 8403HX |
| Condition | Working in Good Condition |
| Series | Video Laryngoscope Blade |
| Direction of View | 0° |
| Working Length | 109 mm |
| Width of Handle | 28 mm |
| Width of Distal End | 19 mm |
| Field of Application | Adults |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!