Insertion Tube For PENTAX EG-2990K Gastroscope

$0.00

► Brief Description

The PENTAX Medical EG-2990K is a high-performance video gastroscope designed for advanced upper GI diagnostics,offering a balance of high-definition imaging and reliable therapeutic capabilities.

â–º Features

  • Large Therapeutic Channel
  • Dedicated Forward Water Jet
  • Advanced Maneuverability
  • Durability and Reprocessing

â–ºSepecification

Brand PENTAX
Model EG-2990K
Condition Brand new
Series Insertion tube
Insertion Tube Diameter 9.8 mm
Instrument (Biopsy) Channel 2.8 mm
Working Length 1,050 mm
Total Length 1,395 mm
Angulation Range (Up/Down) 210° / 120°
Angulation Range (Left/Right) 120° / 120°
Field of View 140°
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Insighters IS3-F laryngoscope for repair

$0.00

► Brief Description

Fault:

1. Image blank screen;

2. Insert tube abrasion

3. Bending section transformation;

4. Distal head transformation;

Solution:

Replace CCD, insert tube, bending section, rubber

â–ºProblem & Solutoin

Brand Insighters
Model IS3-F
Fault 1. Image blank screen; 2. Insert tube abrasion 3. Bending section transformation; 4. Distal head transformation;
Solution Replace CCD, insert tube, bending section, rubber

► Common issues with IS3-F laryngoscope

  • Bending Section Issues
  • Insertion Tube Damage
  • Optical/Image System Problems
  • Fluid Leaks
  • Channel Obstructions
  • Light Guide and Illumination Issues

Insighters IS3-F laryngoscope for repair, sn£ºCAA19****

Insighters IS3-F laryngoscope for repair, sn£ºCAA19**** for sale, Buy brand new flexible endoscope repair parts for Insighters.Order now!

Insulating strip for Harmonic HAR23 Curved

Insulating strip for Harmonic HAR23 Curved for sale, Buy brand new Surgical Instrument for .Order now!

Insulating strip for Harmonic HAR36 Curved

Insulating strip for Harmonic HAR36 Curved for sale, Buy brand new Surgical Instrument for .Order now!

insulating strip for T3905/T3935

insulating strip for T3905/T3935 for sale, Buy brand new Surgical Instrument for .Order now!

Integra S6 Dermatome handpiece for repair

Integra S6 Dermatome handpiece for repair for sale, Buy brand new flexible endoscope repair parts for Integra.Order now!

ITG M-11 Medical Oxygen Sensor

ITG M-11 Medical Oxygen Sensor for sale, Buy brand new PCR and Centrifuge for ITG.Order now!

Johnson & Johnson Ethicon AP4010S Clip Applicator

Johnson & Johnson Ethicon AP4010S Clip Applicator for sale, Buy brand new PCR and Centrifuge for Ethicon.Order now!

Johnson & Johnson Ethicon Har23/Har36 Ultrasonic Scissors Core

Johnson & Johnson Ethicon Har23/Har36 Ultrasonic Scissors Core for sale, Buy brand new PCR and Centrifuge for Ethicon.Order now!

KANGJI Bipolar Forceps Jaws

KANGJI Bipolar Forceps Jaws for sale, Buy brand new PCR and Centrifuge for KANGJI.Order now!

KANGJI Laparoscopic Curved Scissor Forceps Graspers Laparoscopy Instruments set-4Pc 5mm

KANGJI Laparoscopic Curved Scissor Forceps Graspers Laparoscopy Instruments set-4Pc 5mm for sale, Buy brand new PCR and Centrifuge for KANGJI.Order now!

KARL STORZ 11274AA1 Ureteroscope for repair

KARL STORZ 11274AA1 Ureteroscope for repair for sale, Buy brand new flexible endoscope repair parts for Karl Storz.Order now!

KARL STORZ 11278A1 ureteroscope for repair

$0.00

► Brief Description

Fault:

1) Image spotted with partially black point, image bundle aged

2) Light bundle partially wire broken

3) Insert tube aged

4) Biopsy tube abrasion and leakage

5) Wires and coil pipe abrasion

Solution:

Replace HD image bundle, light bundle, insert tube, wires, coil pipe and rubber.

â–ºProblem & Solutoin

Brand KARL STORZ
Model 11278A1
Fault 1) Image spotted with partially black point, image bundle aged 2) Light bundle partially wire broken 3) Insert tube aged 4) Biopsy tube abrasion and leakage 5) Wires and coil pipe abrasion
Solution Replace HD image bundle, light bundle, insert tube, wires, coil pipe and rubber.

► Common issues with 11278A1 ureteroscope

  • Image/Optical System Problems
  • Sheath/Working Element Issues
  • Light Transmission Problems
  • Channel Obstructions
  • Overall Integrity/Physical Damage

KARL STORZ 11278A1 ureteroscope for repair. SN: 225****

KARL STORZ 11278A1 ureteroscope for repair. SN: 225**** for sale, Buy brand new flexible endoscope repair parts for KARL STORZ.Order now!

Karl Storz 222010 20 Image 1 HD HUB Camera Control Unit for repair

Karl Storz 222010 20 Image 1 HD HUB Camera Control Unit for repair for sale, Buy brand new Camera system for Karl Storz.Order now!

Fix Once Right, Save Replacement Costs

Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.

However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.

Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.

If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!