SHOP

Olympus SonoSurg-MAJ-1215 handpiece for repaired

Olympus SonoSurg-MAJ-1215 handpiece for repaired for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!

Olympus SonoSurg-T2H-C Ultrasonic Transducer

$0.00

► Brief Description

The SonoSurg-T2H-C is a high-performance handheld transducer (handpiece) that converts electrical energy from the generator into mechanical longitudinal vibrations.

â–ºFeatures

  • Energy Conversion: Utilizes piezoelectric ceramic elements to generate ultrasonic waves.
  • Surgical Action: When attached to a compatible probe (scissors or blade), it enables simultaneous cutting and coagulation (hemostasis) of soft tissue using frictional heat.
  • Suction Capability: Designed with an internal channel to support smoke and fluid evacuation during laparoscopic or open procedures.

► Specification

Brand Olympus
Model SonoSurg-T2H-C
Condition Brand new
Series Ultrasonic Transducer
Operating Frequency Approximately 23.5kHz
Generator Compatibility Olympus SonoSurg G2
Vibration Mode Longitudinal Ultrasonic Vibration
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Olympus SonoSurg-T2L-GE-O transducer for repaired

Olympus SonoSurg-T2L-GE-O transducer for repaired for sale, Buy brand new flexible endoscope repair parts for Olympus.Order now!

Olympus SonoSurg-T2L-GE-O transducer,SN:941**** for repaired

Olympus SonoSurg-T2L-GE-O transducer,SN:941**** for repaired for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!

OLYMPUS SUCTION VALVE MAJ-1443

OLYMPUS SUCTION VALVE MAJ-1443 for sale, Buy brand new Flexible Endoscope for Olympus.Order now!

Olympus T3110 SonoSurg Scissors for repair

Olympus T3110 SonoSurg Scissors for repair for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!

OLYMPUS T3775 LAPAROSCOPIC SCISSORS

OLYMPUS T3775 LAPAROSCOPIC SCISSORS for sale, Buy brand new PCR and Centrifuge for Olympus.Order now!

OLYMPUS T3905 LAPAROSCOPIC SCISSORS

OLYMPUS T3905 LAPAROSCOPIC SCISSORS for sale, Buy brand new PCR and Centrifuge for Olympus.Order now!

OLYMPUS T3925/T3775/T3905/T3105/T3915 LAPAROSCOPIC SCISSORS

OLYMPUS T3925/T3775/T3905/T3105/T3915 LAPAROSCOPIC SCISSORS for sale, Buy brand new PCR and Centrifuge for Olympus.Order now!

Olympus TJF-160VR endoscope for repair

$0.00

► Brief Description

Fault:

1.No image, CCD broken.

2. Light bundle broken completely.

3. Insert tube aging and wrinkle.

4. Biopsy tube broken.

5. Wires and helix tube broken.

6. clamp wires broken.

7. Operation part broken, no angle.

8. Grip broken.

9. The scope be separated by someone before, some parts missing.

Solution:

Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube, clamp wires,grip,operation part and rubber.

â–ºProblem & Solutoin

Brand Olympus
Model TJF-160VR
Fault 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The scope be separated by someone before, some parts missing.
Solution Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube, clamp wires,grip,operation part and rubber.

► Common issues with TJF-160VR endoscope

  • Elevator Mechanism Problems
  • Bending Section Issues
  • Image and Optical Problems
  • Channel Problems (Air, Water, Suction)
  • External Damage and Wear

OLYMPUS TJF-160VR endoscope for repair,SN: 250****.

OLYMPUS TJF-160VR endoscope for repair,SN: 250****. for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!

OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR

$0.00

► Brief Description

Fault:

1. Image ok;
2. Light bundlestill ok;
3. Insert tubestill ok;
4. Biopsy tubewear;
5. Bendingsection, wires and helix tube wear;
6. Knob leakage.

Solution:

Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD).

â–ºProblem & Solutoin

Brand OLYMPUS
Model TJF-Q180V
Fault 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. Bendingsection, wires and helix tube wear; 6. Knob leakage.
Solution Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD)

► Common issues with TJF-Q180V DUODENOSCOPE

  • Fluid Leaks
  • Contamination and Foreign Material
  • Blocked Channels
  • Angulation Wire Damage
  • Worn Bending Section
  • Forceps Elevator Failure
  • Foggy or Blurred Image
  • Fiber Optic Damage

OLYMPUS TJF-Q180V DUODENOSCOPE SN:270**** FOR REPAIR

OLYMPUS TJF-Q180V DUODENOSCOPE SN:270**** FOR REPAIR for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!

OLYMPUS WA50200A VIDEO URETEROSCOPE

OLYMPUS WA50200A VIDEO URETEROSCOPE for sale, Buy brand new Figid Endoscope for .Order now!

Olympus/Wolf/Starz/ShenDa Nephrology Forceps

Olympus/Wolf/Starz/ShenDa Nephrology Forceps for sale, Buy brand new PCR and Centrifuge for Olympus/Wolf/Starz/ShenDa.Order now!

ON/OFF KEY SWITCH FOR OLYMPUS CLV-260/ CV-260 LIGHT SOURCE

ON/OFF KEY SWITCH FOR OLYMPUS CLV-260/ CV-260 LIGHT SOURCE for sale, Buy brand new Camera system for OLYMPUS.Order now!

Fix Once Right, Save Replacement Costs

Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.

However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.

Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.

If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!