Brand New Main Board For STORZ 22201020 IMAGE1 HUB HD Processor

Apple Shopping Event

Hurry and get discounts up to 20% Read more

Main Board For STORZ 22201020 IMAGE1 HUB HD Processor

► Brief Description

The main board for the Karl Storz 22201020 serves as the central processing unit inside the IMAGE1 HUB HD Camera Control Unit (CCU). As the core printed circuit board (PCB) of the console, it is responsible for managing high-definition image processing, signal conversion, system communication, and input/output control during endoscopic, laparoscopic, and arthroscopic procedures.

►Features

  • High-Definition Video Processing
  • Signal Conversion & Routing
  • System Integration (SCB Control)
  • Data & Media Management

► Specification

Brand STORZ
Model 22201020
Condition Brand new
Series Main Board
Maximum Resolution 1920 x 1080 pixels (Progressive Scan)
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

 

Warranty Policy

All new aftermarket parts come with a 1-Year warranty. Quality is the first thing we consider. Check out our Warranty Assistance for more details.

Shipping Policy

All expedited shipping so you can get your medical machine back in action, fast. Check out our Shipping Policy for more details.

Easy Return Policy

We prioritize your satisfaction. If your order doesn't meet your expectations within 90 days, you may be eligible for a refund. See our Easy Return Policy for details.

Description

Main Board For STORZ 22201020 IMAGE1 HUB HD Processor

0d448c0a8f4b64f8a3a2d3b5162b27fd 412356c88cfae1cec04967fcf984b744 28fbdc32deed357cd4221517352846bc

► Brief Description

The main board for the Karl Storz 22201020 serves as the central processing unit inside the IMAGE1 HUB HD Camera Control Unit (CCU). As the core printed circuit board (PCB) of the console, it is responsible for managing high-definition image processing, signal conversion, system communication, and input/output control during endoscopic, laparoscopic, and arthroscopic procedures.

►Features

  • High-Definition Video Processing
  • Signal Conversion & Routing
  • System Integration (SCB Control)
  • Data & Media Management

► Specification

Brand STORZ
Model 22201020
Condition Brand new
Series Main Board
Maximum Resolution 1920 x 1080 pixels (Progressive Scan)
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

 

► FAQ

What are the common symptoms of a faulty main board in a STORZ 22201020 console?

  • Answer: Common indicators of a failing or damaged main board include:

    • Complete failure to power on or frequent unexpected reboots.

    • No video output or abnormal display artifacts (e.g., green screens, scrambling, vertical/horizontal lines).

    • Inability to recognize connected camera heads (e.g., H3-Z series) or external peripherals.

    • Error codes or freezing during the initialization/boot-up sequence.

    • Failure to save user settings or communicate via the SCB network.

What causes the main board in the 22201020 CCU to fail?

  • Answer: Primary causes include:

    • Power surges or electrical fluctuations.

    • Normal component aging (such as degradation of electrolytic capacitors or SMD components).

    • Liquid ingress or internal contamination (dust, debris, or moisture from hospital environments).

    • Electrostatic discharge (ESD) during improper handling or maintenance.

► More service

Spare parts for Wolf camera head, such as CCD, cable, cover, sheath/strain relief, etc.
Camera system brand by OLYMPUS, WOLF, STORZ, Stryker, Smith&Nephew, ScanMed, etc.

Main models of camera head:
5502, 5506, 5507, 5509, 5512, 5516, 5525, 5550, etc by Wolf;
OTV-S4, OTV-S5, OTV-SX2, OTV-SC, OTV-S6, OTV-S7, CV-165, etc by Olympus;
22201020, 20242020, 22202022, 20212020, etc by Storz Image 1 HUB HD;
888i, 988i, 1088/1088HD, 1188/1188HD, 1288/1288HD, 1488/1488HD, 1588/1588HD, 1688/1688HD, etc by Stryker;
460P, 560P, ED-3, 325Z, 350, etc by Smith&Nephew.

► About Us

CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.

Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.

Product details

In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.

Product details

In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.

Description

Main Board For STORZ 22201020 IMAGE1 HUB HD Processor

0d448c0a8f4b64f8a3a2d3b5162b27fd 412356c88cfae1cec04967fcf984b744 28fbdc32deed357cd4221517352846bc

► Brief Description

The main board for the Karl Storz 22201020 serves as the central processing unit inside the IMAGE1 HUB HD Camera Control Unit (CCU). As the core printed circuit board (PCB) of the console, it is responsible for managing high-definition image processing, signal conversion, system communication, and input/output control during endoscopic, laparoscopic, and arthroscopic procedures.

►Features

  • High-Definition Video Processing
  • Signal Conversion & Routing
  • System Integration (SCB Control)
  • Data & Media Management

► Specification

Brand STORZ
Model 22201020
Condition Brand new
Series Main Board
Maximum Resolution 1920 x 1080 pixels (Progressive Scan)
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

 

► FAQ

What are the common symptoms of a faulty main board in a STORZ 22201020 console?

  • Answer: Common indicators of a failing or damaged main board include:

    • Complete failure to power on or frequent unexpected reboots.

    • No video output or abnormal display artifacts (e.g., green screens, scrambling, vertical/horizontal lines).

    • Inability to recognize connected camera heads (e.g., H3-Z series) or external peripherals.

    • Error codes or freezing during the initialization/boot-up sequence.

    • Failure to save user settings or communicate via the SCB network.

What causes the main board in the 22201020 CCU to fail?

  • Answer: Primary causes include:

    • Power surges or electrical fluctuations.

    • Normal component aging (such as degradation of electrolytic capacitors or SMD components).

    • Liquid ingress or internal contamination (dust, debris, or moisture from hospital environments).

    • Electrostatic discharge (ESD) during improper handling or maintenance.

► More service

Spare parts for Wolf camera head, such as CCD, cable, cover, sheath/strain relief, etc.
Camera system brand by OLYMPUS, WOLF, STORZ, Stryker, Smith&Nephew, ScanMed, etc.

Main models of camera head:
5502, 5506, 5507, 5509, 5512, 5516, 5525, 5550, etc by Wolf;
OTV-S4, OTV-S5, OTV-SX2, OTV-SC, OTV-S6, OTV-S7, CV-165, etc by Olympus;
22201020, 20242020, 22202022, 20212020, etc by Storz Image 1 HUB HD;
888i, 988i, 1088/1088HD, 1188/1188HD, 1288/1288HD, 1488/1488HD, 1588/1588HD, 1688/1688HD, etc by Stryker;
460P, 560P, ED-3, 325Z, 350, etc by Smith&Nephew.

► About Us

CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.

Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Brand New Main Board For STORZ 22201020 IMAGE1 HUB HD Processor”

Your email address will not be published. Required fields are marked *

Fix Once Right, Save Replacement Costs

Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.

However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.

Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.

If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!