Fujifilm
Product Categories
- NEW PRODUCT 6
- Parts for Anesthesia 0
- Parts for Camera system 86
- Parts for Defibrillator 0
- Parts for Dynamical System 86
- Parts for Flexible Endoscope 327
- Parts for Microplate Reader 1
- Parts for Monitor 7
- Parts for MRI 0
- Parts for Rigid Endoscope 11
- Parts for Surgical Instrument 47
- Parts for Ultrasound & Probe 88
- Parts for Ventilator 91
- PCR and Centrifuge 8
- Repair Cases 172
- Repair Tools 23
- Repair Training Course 7
Featured Products
-
Medical Equipment Repair Certification Course Of Olympus 260 Series Flexible Endoscope Repair Training Course For Kazakhstani Clients
-
Advanced Medical Equipment Repair Certification Repair Training Course Of Rigidscope Training For Italy Client
-
Advanced Medical Equipment Repair Certification Course Of Olympus 290 Colonoscopy and Bronchoscopy For South Korean Client
-
Advanced Medical Equipment Repair Certification Repair Training Course Of Camera Head Training For Italy Clients
Showing all 10 results
Advanced Certified Flexible Endoscope Medical Device Repair Training Course Equipment Repair Technician Training
COURSE:
Flexible Endoscope Repair Training Course
Brands:
OLYMPUS, FUJINON
Gastroscope, Colonoscope, Duodenoscope, Bronchoscope, Fiberscope, Enteroscope, Hysteroscope
Duration:
5 Days / 4 hours per day (20 hours total)
Course Schedule:
Courses run on demand. We open the course when you ask for it and arrange the dates together with you.
Instructor:
Experienced Medical Device Repair Specialist.
Training Models:
OLYMPUS:100 series,140 series,160 series,200 series,240 series,260 series,280 series,290 series,V70 series.
FUJINON:200 series,400 series,500 series,600 series, 700 series.
Subject of Training:
1. Introduction of the basic principles and categories of flexiblescope
2. Introduction of flexiblescope system named
3. The name and structure of each part of flexiblescope
4. The introduction of Olympus EVIS LUCERA SPECTRUM system
5.Common fault alanysis of flexible
6. The concept of grade repair and non-grade repair of flexiblescope
7. The correct usage ways of flexiblescope
8. The Maintenance of Flexiblescope
9. Leakage detection of Flexiblescope
10.Training of minor repair
11. Electronic flexiblecscope disassembly and structure explanation
12.disassembly scope in group
Advanced Medical Equipment Repair Certification Course Of Olympus 290 Colonoscopy and Bronchoscopy For South Korean Client
Medical Equipment Repair Certification Course Of Olympus 290 Colonoscopy and Bronchoscopy For South Korean Client
The courses we organize and their contents are as follows.
COURSE:
Olympus 290 Colonoscopy and Bronchoscopy Repair Training Course
Brands:
OLYMPUS, FUJINON
Duration:
5 Days / 4 hours per day (20 hours total)
Course Schedule:
Courses run on demand. We open the course when you ask for it and arrange the dates together with you.
Instructor:
Experienced Medical Device Repair Specialist.
Training Models:
OLYMPUS:100 series,140 series,160 series,200 series,240 series,260 series,280 series,290 series,V70 series.
FUJINON:200 series,400Â series,500Â series,600Â series, 700Â series.
Subject of Training:
1.Disassembly and structure explanation of the light guide section , operation section and insertion part of the BF-P290 bronchoscope.
2.Disassemble the various components at the tip of BF-P290 and clean all the pipes. Understand the various accessories at the tip (Demonstration)
3.Disassemble the various components at the tip of BF-P290 and clean all the pipes. Understand the various accessories at the tip (Hands-on operation)
4.Installation of BF-P290 forcep tube and light bundle (Demonstration)
5.Installation of BF-P290 forcep Tube (Hands-on operation)
6.Replace the BF-P290 insertion tube (Demonstration)
7.Replace the BF-P290 insertion tube (Hands-on operation)
8.Insertion tube installing (Demonstration)
9.Insertion tube installing (Hands-on operation)
10.Replace the rubber and apply the glue (Demonstration)
11.Disassembly and Structural Explanation of the Insertion Part Component of CF-HQ290I Colonoscope
12.Disassemble the various components at the tip of CF-HQ290I and clean all the pipes. Understand the various accessories at the tip (demonstration and hands-on operation)
13.Replacing the forcep tube (Demonstration and hands-on operation)
14.Replace air&water tube and water injection tube (Demonstration and hands-on operation)
15.Replace the light bundle (Demonstration and hands-on operation)
16.Replace CF-HQ290I insertion tube (Demonstration)
17.Welding of CF-HQ290I steel wire assembly (Demonstration)
18.Welding of CF-HQ290I steel wire assembly (Hands-on operation)
19.Replace the steel mesh (Demonstration)
20.Replace the steel mesh (Hands-on operation)
21.Insertion tube installing (Demonstration)
22.Insertion tube installing (Hands-on operation)
23.Replace the rubber and apply the AB glue (Demonstration)
24.Replace the rubber (Hands-on operation)
25.Apply the AB glue (Hands-on operation)
Advanced Medical Equipment Repair Certification Repair Training Course Of Camera Head Training For Italy Clients
Medical Equipment Repair Certification Course Of Camera Head Training For Italy Clients
COURSE:
Camera Head Repair Training Course
Brands:
OLYMPUS, WOLF, STORZ, Stryker, Smith&Nephew, etc.
Duration:
5 Days / 4 hours per day (20 hours total)
Course Schedule:
Courses run on demand. We open the course when you ask for it and arrange the dates together with you.
Instructor:
Experienced Medical Device Repair Specialist.
Training Models:
OLYMPUS:OTV-S4,OTV-S5,OTV-SX2,OTV-SC,OTV-S6,OTV-S7,CV-165
WOLF:5502,5506,5507,5509,5512,5516,5525,5550
STORZ:22201020,20242020,22202022,20212020
Stryker:888i,988i,1088/1088HD,1188/1188HD,1288/1288HD,1488/1488HD,1588/1588HD,1688/1688HD
Smith&Nephew:460P,560P,ED-3,325Z,350
Subject of Training:
1.Common brands of camera head , applications and faults
2.Disassembly and Assembly of Camera head and Tools
3.Detection methods and fault diagnosis of Camera head
4.Camera detection and practical operation of tool usage
5.Cable Detection method of Storz H3-Z
6.Cable Disassembly and Wiring of Storz H3-Z
7.Cable Maintenance Practical Operation of Storz H3-Z
8.Disassembly and Installation of OTV-S7ProH-HD-12E
9.Cable Detection method of OTV-S7ProH-HD-12E
10.Cable repair for OTV-S7ProH-HD-12E
11.Cable Maintenance Practical Operation of OTV-S7ProH-HD-12E
12.Disassembly and Installation of CH-S190-XZ-E
13.Cable Detection method of CH-S190-XZ-E
14.Cable Disassembly and Wiring of CH-S190-XZ-E
15.Cable Maintenance Practical Operation of CH-S190-XZ-E
Advanced Medical Equipment Repair Certification Repair Training Course Of Rigid scope For Indian client
Medical Equipment Repair Certification Course Of Rigidscope For Indian client
COURSE:
Rigid scope Repair Training Course
Brands:
KARL STORZ,Olympus,Stryker,Richard Wolf,Smith & Nephew,Aesculap,Conmed
Laparoscope,Thoracoscope,Arthroscope,Spine Endoscope,Cystoscope,Ureteroscope,Nephroscope
Duration:
5 Days / 4 hours per day (20 hours total)
Course Schedule:
Courses run on demand. We open the course when you ask for it and arrange the dates together with you.
Instructor:
Experienced Medical Device Repair Specialist.
Training Models:
KARL STORZ: 26003BA,26033BA,26605BA,27005BA, 7230AA,7230BA,26046BA,26046AA,etc.
Olympus: WA53005A,WA53000A,WA50373B,WA50372B,WA2T430A,A4674A,WA29040A,etc.
Stryker:502-104-030,etc.
Richard Wolf:8964.401,8645.403,etc.
Smith & Nephew:7205681,72202087,72205154,7208133,etc.
Aesculap:PE610A,PE485A,etc.
Conmed:HD4300
Subject of Training:
1.The structure,function,brands for rigid scope
2.Fault judgment and detection method of arthroscope
3.Rigid scope disassembly & assembly teaching
4.Practice to disassemble & assemble
5.Internal structure teaching & disassembly & assembly
6.Rod lens disassembly and debugging
7.Practise to rod lens debugging
8.Summary &Practise
9.Inner &outer tube and fiber disaasembly & assembly Teacing
10.Practice to Inner &outer tube and fiber disaasembly & assembly
11.Adjust the image, Fault judgement, Practice
Advanced Medical Equipment Repair Certification Repair Training Course Of Rigidscope Training For Italy Client
Medical Equipment Repair Certification Course Of Rigidscope Training For Italy Client
The courses we organize and their contents are as follows.
COURSE:
Rigid scope Repair Training Course
Brands:
KARL STORZ,Olympus,Stryker,Richard Wolf,Smith & Nephew,Aesculap,Conmed
Duration:
5 Days / 4 hours per day (20 hours total)
Course Schedule:
Courses run on demand. We open the course when you ask for it and arrange the dates together with you.
Instructor:
Experienced Medical Device Repair Specialist.
Training Models:
KARL STORZ:Â 26003BA,26033BA,26605BA,27005BA, 7230AA,7230BA,26046BA,26046AA,etc.
Olympus:Â WA53005A,WA53000A,WA50373B,WA50372B,WA2T430A,A4674A,WA29040A,etc.
Stryker:502-104-030,etc.
Richard Wolf:8964.401,8645.403,etc.
Smith & Nephew:7205681,72202087,72205154,7208133,etc.
Aesculap:PE610A,PE485A,etc.
Conmed:HD4300
Subject of Training:
1.The structure,function,brands for rigid scope
2.Fault judgment and detection method of arthroscope
3.Rigid scope disassembly & assembly teaching
4.Practice to disassemble & assemble
5.Internal structure teaching & disassembly & assembly
6.Rod lens disassembly and debugging
7.Practise to rod lens debugging
8.Summary &Practise
9.Inner &outer tube and fiber disaasembly & assembly Teacing
10.Practice to Inner &outer tube and fiber disaasembly & assembly
11.Adjust the image, Fault judgement, Practice
Bending Section Assembly For Fujifilm EG-580NW2 Gastroscope
$0.00► Brief Description
The bending section of the EG-580NW2 is designed with a small bending radius to facilitate “Smart Bend” technology, providing high maneuverability even in tight spaces.
► Features
- Precision Navigation (Steering):Â It translates the mechanical rotation of the control knobs into physical movement, allowing the clinician to navigate the nasal meatus and the esophagus with minimal trauma.
- Retroflexion Capability: With a 210° Up-bend, the assembly allows the scope to turn back on itself. This is critical for inspecting the “blind spots” of the stomach (the cardia and fundus).
- Internal Component Protection:Â It acts as a protective conduit for delicate internals (the 2.4mm instrument channel, fiber optic bundles, and the Super CCD wiring), ensuring they do not kink or break during extreme angulation.
- Torque Transmission:Â The “Snake Bone” design ensures that when the doctor twists the handle (torque), the tip rotates 1:1, providing predictable and responsive handling.
-
Pressure Management: The assembly is designed to maintain a consistent internal diameter for the 2.4mm forceps channel, ensuring that suction power remains constant even when the tip is fully deflected.​
► Specification
| Brand | Fujifilm |
| Model | EG-580NW2 |
| Condition | Compatible & new |
| Series | Bending Section Assembly |
| Up | 210° |
| Down | 90° |
| Left | 100° |
| Right | 100° |
| Section Diameter | 5.8 mm |
| Bending Radius | Ultra-Short(Optimized for narrow passages) |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Brand New Left/Right Angulation Control Knob For Fujifilm EG-760Z Video Gastroscope
â–º Brief Description
The Left/Right Angulation Control Knob is a core mechanical component located on the operation control body (G7 grip) of the Fujifilm EG-760Z optical magnification gastroscope. It is engineered to provide smooth, highly responsive lateral steering of the endoscope’s distal tip, allowing clinicians to precisely navigate the upper gastrointestinal (GI) tract and target specific mucosal lesions during high-resolution observations.
â–º Features
- Lateral Tip Deflection:Directly controls the steering wires inside the insertion tube to sweep the distal tip horizontally up to 100° left and 100° right, granting comprehensive side-to-side panoramic views of the stomach and esophageal walls.
- Friction and Angle Locking:Often paired with a designated Left/Right Angle Lock Lever, allowing the operator to freeze or secure the horizontal bending position in place once a target area is successfully locked in the field of view. This prevents hand fatigue and maintains stable optical zoom focus during detailed examinations.
- Ergonomic Sensitivity:Designed to turn smoothly with calibrated resistance, minimizing backlash and giving the physician precise tactile feedback during delicate diagnostic and therapeutic maneuvering.
â–º Specification
| Brand | Fujifilm |
| Model | EG-760Z |
| Condition | Brand new |
| Series | Angulation Control Knob |
| Left Bending Range | 100° |
| Right Bending Range | 100° |
| Operation Mechanism | Dual coaxial mechanical pulley/wire-driven system |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Insert Tube For Fujifilm EG-530NW video gastroscope
$0.00► Brief Description
The insertion tube (also known as the flexible portion) is the key component of the endoscope that is inserted into the patient’s body.
► Features
- Ultrathin Design: The 5.9mm diameter is significantly smaller than standard gastroscopes, facilitating transnasal (through-the-nose) insertion. This is the primary function of the small diameter, greatly improving patient tolerance and reducing the gag reflex.
- Flexibility and Torque Transmission:Â The flexible section is engineered to effectively transmit rotational (torque), pushing, and pulling movements from the control body to the distal tip, allowing for precise steering within the anatomy.
- Instrument Channel Access: The 2.0mm channel runs through the entire length of the tube, allowing for the delivery and manipulation of instruments (like biopsy forceps or cytology brushes) and providing suction.
- Light and Imaging Components:Â The tube contains the necessary light guides and wiring to power the CMOS/Super CCD sensor at the distal tip and transmit the high-resolution image data back to the video processor.
- Smart Bending Technology:The bending section at the end of the tube provides an exceptionally large 210° up-angulation, which is crucial for maneuvering into retroflexed positions to thoroughly examine the gastric cardia and fundus.
► Specification
| Brand | Fujifilm |
| Model | EG-530NW |
| Condition | Brand new |
| Series | Insert Tube |
| Outer Diameter | 5.9mm |
| Working Length | 1100mm |
| Total Length | 1400mm |
| Instrument (Working) Channel Diameter | 2.0mm |
| Up | 210° |
| Down | 90° |
| Right | 100° |
| Left | 100° |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Medical Equipment Repair Certification Course Of Flexible Endoscope Repair Training Course For South Korean client
Medical Equipment Repair Certification Course Of Flexible Endoscope Repair Training Course For South Korean client
COURSE:
Flexible Endoscope Repair Training Course
Brands:
OLYMPUS, FUJINON
Gastroscope, Colonoscope, Duodenoscope, Bronchoscope, Fiberscope, Enteroscope, Hysteroscope
Duration:
5 Days / 4 hours per day (20 hours total)
Course Schedule:
Courses run on demand. We open the course when you ask for it and arrange the dates together with you.
Instructor:
Experienced Medical Device Repair Specialist.
Training Models:
OLYMPUS:100 series,140 series,160 series,200 series,240 series,260 series,280 series,290 series,V70 series.
FUJINON:200 series,400 series,500 series,600 series, 700 series.
Subject of Training:
1.Understanding types, brands, and applications of flexible endoscopes
2.Flexiblescope with supporting processor teaching
3.Common faults and solution teaching
4.Detecing steps and practice
5.Leakage detecting and practice
6.Bending rubber disassemble & assemble and tools teaching
7.Practice to bending rubber disassemble & assemble
8.The inner structure disassemble & assemble teaching
9.Practice to the inner structure disassemble & assemble
10.Angulation Wire assembly install and teaching
11.Replace angulation Wire and practice
12.Practice to the inner structure disassemble & assemble
Medical Equipment Repair Certification Course Of Olympus 260 Series Flexible Endoscope Repair Training Course For Kazakhstani Clients
Medical Equipment Repair Certification Course Of Olympus 260 Series Flexible Endoscope Repair Training Course For Kazakhstani Clients
The courses we organize and their contents are as follows.
COURSE:
Olympus 260 Series Flexible Endoscope Repair Training Course
Brands:
OLYMPUS, FUJINON
Duration:
5 Days / 4 hours per day (20 hours total)
Course Schedule:
Courses run on demand. We open the course when you ask for it and arrange the dates together with you.
Instructor:
Experienced Medical Device Repair Specialist.
Training Models:
OLYMPUS:100 series,140 series,160 series,200 series,240 series,260 series,280 series,290 series,V70 series.
FUJINON:200 series,400 series,500 series,600 series, 700 series.
Subject of Training:
1.Understanding types, brands, and applications of flexible endoscopes
2.Flexiblescope with supporting processor teaching
3.Common faults and solution teaching
4.Detecing steps and practice
5.Leakage detecting and practice
6.Bending rubber disassemble & assemble and tools teaching
7.Practice to bending rubber disassemble & assemble
8.The inner structure disassemble & assemble teaching
9.Practice to the inner structure disassemble & assemble
10.Angulation Wire assembly install and teaching
11.Replace angulation Wire and practice
12.Practice to the inner structure disassemble & assemble
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!