FUJINON

Showing all 13 results

Advanced Certified Flexible Endoscope Medical Device Repair Training Course Equipment Repair Technician Training

COURSE:

Flexible Endoscope Repair Training Course

Brands:

OLYMPUS, FUJINON
Gastroscope, Colonoscope, Duodenoscope, Bronchoscope, Fiberscope, Enteroscope, Hysteroscope

 

Duration:

5 Days / 4 hours per day (20 hours total)

Course Schedule:

Courses run on demand. We open the course when you ask for it and arrange the dates together with you.

Instructor:

Experienced Medical Device Repair Specialist.

Training Models:

OLYMPUS:100 series,140 series,160 series,200 series,240 series,260 series,280 series,290 series,V70 series.

FUJINON:200 series,400 series,500 series,600 series, 700 series.

Subject of Training:

1. Introduction of the basic principles and categories of flexiblescope
2. Introduction of flexiblescope system named
3. The name and structure of each part of flexiblescope
4. The introduction of Olympus EVIS LUCERA SPECTRUM system

5.Common fault alanysis of flexible
6. The concept of grade repair and non-grade repair of flexiblescope

7. The correct usage ways of flexiblescope

8. The Maintenance of Flexiblescope

9. Leakage detection of Flexiblescope

10.Training of minor repair
11. Electronic flexiblecscope disassembly and structure explanation
12.disassembly scope in group

Advanced Medical Equipment Repair Certification Course Of Olympus 290 Colonoscopy and Bronchoscopy For South Korean Client

Medical Equipment Repair Certification Course Of Olympus 290 Colonoscopy and Bronchoscopy For South Korean Client

The courses we organize and their contents are as follows.

COURSE:

Olympus 290 Colonoscopy and Bronchoscopy Repair Training Course

Brands:

OLYMPUS, FUJINON

Duration:

5 Days / 4 hours per day (20 hours total)

Course Schedule:

Courses run on demand. We open the course when you ask for it and arrange the dates together with you.

Instructor:

Experienced Medical Device Repair Specialist.

Training Models:

OLYMPUS:100 series,140 series,160 series,200 series,240 series,260 series,280 series,290 series,V70 series.

FUJINON:200 series,400 series,500 series,600 series, 700 series.

 

Subject of Training:

1.Disassembly and structure explanation of the light guide section , operation section and insertion part of the BF-P290 bronchoscope.

2.Disassemble the various components at the tip of BF-P290 and clean all the pipes. Understand the various accessories at the tip (Demonstration)

3.Disassemble the various components at the tip of BF-P290 and clean all the pipes. Understand the various accessories at the tip (Hands-on operation)

4.Installation of BF-P290 forcep tube and light bundle (Demonstration)

5.Installation of BF-P290 forcep Tube (Hands-on operation)

6.Replace the BF-P290 insertion tube (Demonstration)

7.Replace the BF-P290 insertion tube (Hands-on operation)

8.Insertion tube installing (Demonstration)

9.Insertion tube installing (Hands-on operation)

10.Replace the rubber and apply the glue (Demonstration)

11.Disassembly and Structural Explanation of the Insertion Part Component of CF-HQ290I Colonoscope

12.Disassemble the various components at the tip of CF-HQ290I and clean all the pipes. Understand the various accessories at the tip (demonstration and hands-on operation)

13.Replacing the forcep tube (Demonstration and hands-on operation)

14.Replace air&water tube and water injection tube (Demonstration and hands-on operation)

15.Replace the light bundle (Demonstration and hands-on operation)

16.Replace CF-HQ290I insertion tube (Demonstration)

17.Welding of CF-HQ290I steel wire assembly (Demonstration)

18.Welding of CF-HQ290I steel wire assembly (Hands-on operation)

19.Replace the steel mesh (Demonstration)

20.Replace the steel mesh (Hands-on operation)

21.Insertion tube installing (Demonstration)

22.Insertion tube installing (Hands-on operation)

23.Replace the rubber and apply the AB glue (Demonstration)

24.Replace the rubber (Hands-on operation)

25.Apply the AB glue (Hands-on operation)

 

Advanced Medical Equipment Repair Certification Repair Training Course Of Camera Head Training For Italy Clients

Medical Equipment Repair Certification Course Of Camera Head Training For Italy Clients

COURSE:

Camera Head Repair Training Course

Brands:

OLYMPUS, WOLF, STORZ, Stryker, Smith&Nephew, etc.

 

Duration:

5 Days / 4 hours per day (20 hours total)

Course Schedule:

Courses run on demand. We open the course when you ask for it and arrange the dates together with you.

Instructor:

Experienced Medical Device Repair Specialist.

Training Models:

OLYMPUS:OTV-S4,OTV-S5,OTV-SX2,OTV-SC,OTV-S6,OTV-S7,CV-165

WOLF:5502,5506,5507,5509,5512,5516,5525,5550

STORZ:22201020,20242020,22202022,20212020

Stryker:888i,988i,1088/1088HD,1188/1188HD,1288/1288HD,1488/1488HD,1588/1588HD,1688/1688HD

Smith&Nephew:460P,560P,ED-3,325Z,350

 

Subject of Training:

1.Common brands of camera head , applications and faults

2.Disassembly and Assembly of Camera head and Tools

3.Detection methods and fault diagnosis of Camera head

4.Camera detection and practical operation of tool usage

5.Cable Detection method of Storz H3-Z

6.Cable Disassembly and Wiring of Storz H3-Z

7.Cable Maintenance Practical Operation of Storz H3-Z

8.Disassembly and Installation of OTV-S7ProH-HD-12E

9.Cable Detection method of OTV-S7ProH-HD-12E

10.Cable repair for OTV-S7ProH-HD-12E

11.Cable Maintenance Practical Operation of OTV-S7ProH-HD-12E

12.Disassembly and Installation of CH-S190-XZ-E

13.Cable Detection method of CH-S190-XZ-E

14.Cable Disassembly and Wiring of CH-S190-XZ-E

15.Cable Maintenance Practical Operation of CH-S190-XZ-E

 

Advanced Medical Equipment Repair Certification Repair Training Course Of Rigid scope For Indian client

Medical Equipment Repair Certification Course Of Rigidscope For Indian client

COURSE:
Rigid scope Repair Training Course

Brands:
KARL STORZ,Olympus,Stryker,Richard Wolf,Smith & Nephew,Aesculap,Conmed
Laparoscope,Thoracoscope,Arthroscope,Spine Endoscope,Cystoscope,Ureteroscope,Nephroscope

Duration:
5 Days / 4 hours per day (20 hours total)

Course Schedule:
Courses run on demand. We open the course when you ask for it and arrange the dates together with you.

Instructor:
Experienced Medical Device Repair Specialist.

Training Models:
KARL STORZ: 26003BA,26033BA,26605BA,27005BA, 7230AA,7230BA,26046BA,26046AA,etc.
Olympus: WA53005A,WA53000A,WA50373B,WA50372B,WA2T430A,A4674A,WA29040A,etc.
Stryker:502-104-030,etc.
Richard Wolf:8964.401,8645.403,etc.
Smith & Nephew:7205681,72202087,72205154,7208133,etc.
Aesculap:PE610A,PE485A,etc.
Conmed:HD4300

Subject of Training:
1.The structure,function,brands for rigid scope
2.Fault judgment and detection method of arthroscope
3.Rigid scope disassembly & assembly teaching
4.Practice to disassemble & assemble
5.Internal structure teaching & disassembly & assembly
6.Rod lens disassembly and debugging
7.Practise to rod lens debugging
8.Summary &Practise
9.Inner &outer tube and fiber disaasembly & assembly Teacing
10.Practice to Inner &outer tube and fiber disaasembly & assembly
11.Adjust the image, Fault judgement, Practice

Advanced Medical Equipment Repair Certification Repair Training Course Of Rigidscope Training For Italy Client

Medical Equipment Repair Certification Course Of Rigidscope Training For Italy Client

The courses we organize and their contents are as follows.

COURSE:

Rigid scope Repair Training Course

 

Brands:

KARL STORZ,Olympus,Stryker,Richard Wolf,Smith & Nephew,Aesculap,Conmed

Duration:

5 Days / 4 hours per day (20 hours total)

Course Schedule:

Courses run on demand. We open the course when you ask for it and arrange the dates together with you.

Instructor:

Experienced Medical Device Repair Specialist.

Training Models:

KARL STORZ: 26003BA,26033BA,26605BA,27005BA, 7230AA,7230BA,26046BA,26046AA,etc.
Olympus: WA53005A,WA53000A,WA50373B,WA50372B,WA2T430A,A4674A,WA29040A,etc.

Stryker:502-104-030,etc.

Richard Wolf:8964.401,8645.403,etc.

Smith & Nephew:7205681,72202087,72205154,7208133,etc.

Aesculap:PE610A,PE485A,etc.

Conmed:HD4300

 

Subject of Training:

1.The structure,function,brands for rigid scope

2.Fault judgment and detection method of arthroscope

3.Rigid scope disassembly & assembly teaching

4.Practice to disassemble & assemble

5.Internal structure teaching & disassembly & assembly

6.Rod lens disassembly and debugging

7.Practise to rod lens debugging

8.Summary &Practise

9.Inner &outer tube and fiber disaasembly & assembly Teacing

10.Practice to Inner &outer tube and fiber disaasembly & assembly

11.Adjust the image, Fault judgement, Practice

Bending Section Assembly For FUJINON EG-250WR Gastroscope

$0.00

► Brief Description

The Bending Section Assembly is a critical component located at the distal end of the endoscope’s Insertion Tube.It typically comes as a complete module designed to restore the steering function of the endoscope’s distal tip.

► Features

  • To enable four-way angulation (steering) of the endoscope’s distal tip (Up/Down, Left/Right) via the control knobs on the endoscope body.

► Specification

Brand FUJINON
Model EG-250WR
Condition Brand new
Series Bending Section Assembly
Up 210°
Down 90°
Left 100°
Right 100°
Distal End Diameter Approximately 9.3 mm
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Bending Section Assembly For FUJINON EG-530D Gastroscope

$0.00

► Brief Description

The Bending Section is controlled by the Angulation Knobs on the control body and connects the distal end tip to the flexible insertion tube.The Bending Section Assembly is the articulating mechanism at the distal end of the endoscope that allows the physician to maneuver and steer the scope within the patient’s upper gastrointestinal tract (esophagus, stomach, and duodenum).

► Features

  • Steering and Navigation
  • Tip Positioning and Stabilization
  • Retroflexion (High Up Angulation)
  • Instrument Alignment and Exit
  • Optical System Alignment

► Specification

Brand FUJINON
Model EG-530D
Condition Brand new
Series Bending Section Assembly
Up 210°
Down 90°
Right 100°
Left 100°
Distal End Diameter 11.5mm
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Brand New Insertion Tube For Fujifilm EG-250WR5 Gastroscope

$0.00

► Brief Description

The Fujifilm EG-250WR5 is a high-resolution video gastroscope known for its wide-angle view and slim design, widely used for upper gastrointestinal examinations.

► Features

  • Slim-Diameter Profile
  • Graduated Flexibility (G-Flex)
  • High-Durability Multi-Layer Construction
  • Smooth Low-Friction Coating
  • Optimized Bending Section
  • Integrated Multi-Channel Internal Design

► Specification

Brand Fujifilm
Model EG-250WR5
Condition Brand new
Series Insertion Tube
Distal End Diameter 9.4 mm
Insertion Tube Diameter 9.3 mm
Working Length 1,100 mm
Total Length 1,400 mm
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

FUJINON EG-530N gastroscope for repair

$0.00

► Brief Description

Fault:

1.Biopsy tube broken;

2.Angle is not enough;

3.Camera over-heating, there are occasional snowflakes on the image and big risk for CCD;

4.Insert tube aging and wrinkle;

5.Light guide tube aging and wrinkleï¼›

6.Stress boot of light guide tube broken;

7.Light bundle broken;

8.EVE tube aging and wrinkle.

Solution:

1: Replace CCD; insert tube; light bundle; biopsy tube; bending mesh; wires; bending section; rubber; light guide tube; stress boot; eve tube

2: Replace insert tube, light bundle, biopsy tube, bending mesh and wired, coil pipe, rubber, light guide tube, stress tube, eve tube

3: Replace insert tube, light bundle, biopsy tube, bending mesh and wires, bending section, rubber

â–ºProblem & Solutoin

Brand FUJINON
Model EG-530N
Fault 1.Biopsy tube broken; 2.Angle is not enough; 3.Camera over-heating, there are occasional snowflakes on the image and big risk for CCD; 4.Insert tube aging and wrinkle; 5.Light guide tube aging and wrinkleï¼› 6.Stress boot of light guide tube broken; 7.Light bundle broken; 8.EVE tube aging and wrinkle.
Solution 1: Replace CCD; insert tube; light bundle; biopsy tube; bending mesh; wires; bending section; rubber; light guide tube; stress boot; eve tube Solution 2: Replace insert tube, light bundle, biopsy tube, bending mesh and wired, coil pipe, rubber, light guide tube, stress tube, eve tube Solution 3: Replace insert tube, light bundle, biopsy tube, bending mesh and wires, bending section, rubber

► Common issues with EG-530N gastroscope

  • Poor Image Quality
  • Insertion Tube Issues
  • Suction/Air/Water Issues
  • Instrument Channel Problems
  • Damaged Control Body
  • Loose Angulation Knobs
  • Light Guide Fiber Breakage

Insertion Tube for FUJINON EG-250WR5 Gastroscope

$0.00

► Brief Description

The Insertion Tube is the flexible, slender shaft of the endoscope that the physician inserts into the patient’s digestive tract. Its main functions are to facilitate visualization, manipulation, and treatment within the body.

► Features

  • Insertion and Navigation
  • Internal Component Containment
  • Steering Mechanism
  • Working Channel Passage
  • Suction, Irrigation, and Air/Water Delivery

► Specification

Brand FUJINON
Model EG-250WR5
Condition Brand new
Series Insertion Tube
Insertion Tube Diameter 9.3 mm
Working Length 1,030 mm
Total Length 1,350 mm
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Insertion Tube For FUJINON EG-530D Gastroscope

$0.00

► Brief Description

The insertion tube is the long, flexible part of the endoscope that is inserted into the patient’s body.

► Features

  • Tip Deflection/Angulation
  • Instrument Channel (Biopsy/Suction Channel)
  • Air/Water Channel
  • High-Resolution Image Delivery
  • Flexibility and Torque Transmission

 

► Specification

​Brand FUJINON
Model EG-530D
Condition Brand new
Series Insertion Tube
Working Length (WL) 1090 mm
Insertion Tube Diameter 11.5 mm
Instrument Channel Diameter 3.8 mm
Field of View (FOV) 140°
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Medical Equipment Repair Certification Course Of Flexible Endoscope Repair Training Course For South Korean client

Medical Equipment Repair Certification Course Of Flexible Endoscope Repair Training Course For South Korean client

COURSE:

Flexible Endoscope Repair Training Course

Brands:

OLYMPUS, FUJINON
Gastroscope, Colonoscope, Duodenoscope, Bronchoscope, Fiberscope, Enteroscope, Hysteroscope

 

Duration:

5 Days / 4 hours per day (20 hours total)

 

Course Schedule:

Courses run on demand. We open the course when you ask for it and arrange the dates together with you.

Instructor:

Experienced Medical Device Repair Specialist.

Training Models:

OLYMPUS:100 series,140 series,160 series,200 series,240 series,260 series,280 series,290 series,V70 series.

FUJINON:200 series,400 series,500 series,600 series, 700 series.

 

Subject of Training:

1.Understanding types, brands, and applications of flexible endoscopes

2.Flexiblescope with supporting processor teaching

3.Common faults and solution teaching

4.Detecing steps and practice

5.Leakage detecting and practice

6.Bending rubber disassemble & assemble and tools teaching

7.Practice to bending rubber disassemble & assemble

8.The inner structure disassemble & assemble teaching

9.Practice to the inner structure disassemble & assemble

10.Angulation Wire assembly install and teaching

11.Replace angulation Wire and practice

12.Practice to the inner structure disassemble & assemble

Medical Equipment Repair Certification Course Of Olympus 260 Series Flexible Endoscope Repair Training Course For Kazakhstani Clients

Medical Equipment Repair Certification Course Of Olympus 260 Series Flexible Endoscope Repair Training Course For Kazakhstani Clients

The courses we organize and their contents are as follows.

COURSE:

Olympus 260 Series Flexible Endoscope Repair Training Course

Brands:

OLYMPUS, FUJINON

Duration:

5 Days / 4 hours per day (20 hours total)

Course Schedule:

Courses run on demand. We open the course when you ask for it and arrange the dates together with you.

Instructor:

Experienced Medical Device Repair Specialist.

Training Models:

OLYMPUS:100 series,140 series,160 series,200 series,240 series,260 series,280 series,290 series,V70 series.

FUJINON:200 series,400 series,500 series,600 series, 700 series.

 

Subject of Training:

1.Understanding types, brands, and applications of flexible endoscopes

2.Flexiblescope with supporting processor teaching

3.Common faults and solution teaching

4.Detecing steps and practice

5.Leakage detecting and practice

6.Bending rubber disassemble & assemble and tools teaching

7.Practice to bending rubber disassemble & assemble

8.The inner structure disassemble & assemble teaching

9.Practice to the inner structure disassemble & assemble

10.Angulation Wire assembly install and teaching

11.Replace angulation Wire and practice

12.Practice to the inner structure disassemble & assemble

Fix Once Right, Save Replacement Costs

Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.

However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.

Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.

If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!