Olympus

Showing 1–16 of 130 results

Acoustic Lens For Olympus GF-UCT180F Ultrasonic Gastrovideoscope

$0.00

► Brief Description

The Olympus GF-UCT180F (an Ultrasonic Gastrovideoscope) is a sophisticated piece of medical equipment designed for Endoscopic Ultrasound (EUS).The Acoustic Lens is a critical component located at the distal tip of the scope. It focuses the ultrasound beam and ensures seamless energy transmission between the transducer and the body tissue.

► Features

  • Beam Focusing & Image Resolution
  • Impedance Matching
  • Mechanical Protection & Biocompatibility

► Specification

Brand Olympus
Series Acoustic Lens
Condition Brand new
Model GF-UCT180F
Scanning Method Electronic Linear Functions
Frequency Multi-frequency
Scanning Direction Longitudinal
Scanning Angle 180°
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Advanced Certified Flexible Endoscope Medical Device Repair Training Course Equipment Repair Technician Training

COURSE:

Flexible Endoscope Repair Training Course

Brands:

OLYMPUS, FUJINON
Gastroscope, Colonoscope, Duodenoscope, Bronchoscope, Fiberscope, Enteroscope, Hysteroscope

 

Duration:

5 Days / 4 hours per day (20 hours total)

Course Schedule:

Courses run on demand. We open the course when you ask for it and arrange the dates together with you.

Instructor:

Experienced Medical Device Repair Specialist.

Training Models:

OLYMPUS:100 series,140 series,160 series,200 series,240 series,260 series,280 series,290 series,V70 series.

FUJINON:200 series,400 series,500 series,600 series, 700 series.

Subject of Training:

1. Introduction of the basic principles and categories of flexiblescope
2. Introduction of flexiblescope system named
3. The name and structure of each part of flexiblescope
4. The introduction of Olympus EVIS LUCERA SPECTRUM system

5.Common fault alanysis of flexible
6. The concept of grade repair and non-grade repair of flexiblescope

7. The correct usage ways of flexiblescope

8. The Maintenance of Flexiblescope

9. Leakage detection of Flexiblescope

10.Training of minor repair
11. Electronic flexiblecscope disassembly and structure explanation
12.disassembly scope in group

Advanced Medical Equipment Repair Certification Course Of Olympus 290 Colonoscopy and Bronchoscopy For South Korean Client

Medical Equipment Repair Certification Course Of Olympus 290 Colonoscopy and Bronchoscopy For South Korean Client

The courses we organize and their contents are as follows.

COURSE:

Olympus 290 Colonoscopy and Bronchoscopy Repair Training Course

Brands:

OLYMPUS, FUJINON

Duration:

5 Days / 4 hours per day (20 hours total)

Course Schedule:

Courses run on demand. We open the course when you ask for it and arrange the dates together with you.

Instructor:

Experienced Medical Device Repair Specialist.

Training Models:

OLYMPUS:100 series,140 series,160 series,200 series,240 series,260 series,280 series,290 series,V70 series.

FUJINON:200 series,400 series,500 series,600 series, 700 series.

 

Subject of Training:

1.Disassembly and structure explanation of the light guide section , operation section and insertion part of the BF-P290 bronchoscope.

2.Disassemble the various components at the tip of BF-P290 and clean all the pipes. Understand the various accessories at the tip (Demonstration)

3.Disassemble the various components at the tip of BF-P290 and clean all the pipes. Understand the various accessories at the tip (Hands-on operation)

4.Installation of BF-P290 forcep tube and light bundle (Demonstration)

5.Installation of BF-P290 forcep Tube (Hands-on operation)

6.Replace the BF-P290 insertion tube (Demonstration)

7.Replace the BF-P290 insertion tube (Hands-on operation)

8.Insertion tube installing (Demonstration)

9.Insertion tube installing (Hands-on operation)

10.Replace the rubber and apply the glue (Demonstration)

11.Disassembly and Structural Explanation of the Insertion Part Component of CF-HQ290I Colonoscope

12.Disassemble the various components at the tip of CF-HQ290I and clean all the pipes. Understand the various accessories at the tip (demonstration and hands-on operation)

13.Replacing the forcep tube (Demonstration and hands-on operation)

14.Replace air&water tube and water injection tube (Demonstration and hands-on operation)

15.Replace the light bundle (Demonstration and hands-on operation)

16.Replace CF-HQ290I insertion tube (Demonstration)

17.Welding of CF-HQ290I steel wire assembly (Demonstration)

18.Welding of CF-HQ290I steel wire assembly (Hands-on operation)

19.Replace the steel mesh (Demonstration)

20.Replace the steel mesh (Hands-on operation)

21.Insertion tube installing (Demonstration)

22.Insertion tube installing (Hands-on operation)

23.Replace the rubber and apply the AB glue (Demonstration)

24.Replace the rubber (Hands-on operation)

25.Apply the AB glue (Hands-on operation)

 

Advanced Medical Equipment Repair Certification Repair Training Course Of Camera Head Training For Italy Clients

Medical Equipment Repair Certification Course Of Camera Head Training For Italy Clients

COURSE:

Camera Head Repair Training Course

Brands:

OLYMPUS, WOLF, STORZ, Stryker, Smith&Nephew, etc.

 

Duration:

5 Days / 4 hours per day (20 hours total)

Course Schedule:

Courses run on demand. We open the course when you ask for it and arrange the dates together with you.

Instructor:

Experienced Medical Device Repair Specialist.

Training Models:

OLYMPUS:OTV-S4,OTV-S5,OTV-SX2,OTV-SC,OTV-S6,OTV-S7,CV-165

WOLF:5502,5506,5507,5509,5512,5516,5525,5550

STORZ:22201020,20242020,22202022,20212020

Stryker:888i,988i,1088/1088HD,1188/1188HD,1288/1288HD,1488/1488HD,1588/1588HD,1688/1688HD

Smith&Nephew:460P,560P,ED-3,325Z,350

 

Subject of Training:

1.Common brands of camera head , applications and faults

2.Disassembly and Assembly of Camera head and Tools

3.Detection methods and fault diagnosis of Camera head

4.Camera detection and practical operation of tool usage

5.Cable Detection method of Storz H3-Z

6.Cable Disassembly and Wiring of Storz H3-Z

7.Cable Maintenance Practical Operation of Storz H3-Z

8.Disassembly and Installation of OTV-S7ProH-HD-12E

9.Cable Detection method of OTV-S7ProH-HD-12E

10.Cable repair for OTV-S7ProH-HD-12E

11.Cable Maintenance Practical Operation of OTV-S7ProH-HD-12E

12.Disassembly and Installation of CH-S190-XZ-E

13.Cable Detection method of CH-S190-XZ-E

14.Cable Disassembly and Wiring of CH-S190-XZ-E

15.Cable Maintenance Practical Operation of CH-S190-XZ-E

 

Advanced Medical Equipment Repair Certification Repair Training Course Of Rigid scope For Indian client

Medical Equipment Repair Certification Course Of Rigidscope For Indian client

COURSE:
Rigid scope Repair Training Course

Brands:
KARL STORZ,Olympus,Stryker,Richard Wolf,Smith & Nephew,Aesculap,Conmed
Laparoscope,Thoracoscope,Arthroscope,Spine Endoscope,Cystoscope,Ureteroscope,Nephroscope

Duration:
5 Days / 4 hours per day (20 hours total)

Course Schedule:
Courses run on demand. We open the course when you ask for it and arrange the dates together with you.

Instructor:
Experienced Medical Device Repair Specialist.

Training Models:
KARL STORZ: 26003BA,26033BA,26605BA,27005BA, 7230AA,7230BA,26046BA,26046AA,etc.
Olympus: WA53005A,WA53000A,WA50373B,WA50372B,WA2T430A,A4674A,WA29040A,etc.
Stryker:502-104-030,etc.
Richard Wolf:8964.401,8645.403,etc.
Smith & Nephew:7205681,72202087,72205154,7208133,etc.
Aesculap:PE610A,PE485A,etc.
Conmed:HD4300

Subject of Training:
1.The structure,function,brands for rigid scope
2.Fault judgment and detection method of arthroscope
3.Rigid scope disassembly & assembly teaching
4.Practice to disassemble & assemble
5.Internal structure teaching & disassembly & assembly
6.Rod lens disassembly and debugging
7.Practise to rod lens debugging
8.Summary &Practise
9.Inner &outer tube and fiber disaasembly & assembly Teacing
10.Practice to Inner &outer tube and fiber disaasembly & assembly
11.Adjust the image, Fault judgement, Practice

Advanced Medical Equipment Repair Certification Repair Training Course Of Rigidscope Training For Italy Client

Medical Equipment Repair Certification Course Of Rigidscope Training For Italy Client

The courses we organize and their contents are as follows.

COURSE:

Rigid scope Repair Training Course

 

Brands:

KARL STORZ,Olympus,Stryker,Richard Wolf,Smith & Nephew,Aesculap,Conmed

Duration:

5 Days / 4 hours per day (20 hours total)

Course Schedule:

Courses run on demand. We open the course when you ask for it and arrange the dates together with you.

Instructor:

Experienced Medical Device Repair Specialist.

Training Models:

KARL STORZ: 26003BA,26033BA,26605BA,27005BA, 7230AA,7230BA,26046BA,26046AA,etc.
Olympus: WA53005A,WA53000A,WA50373B,WA50372B,WA2T430A,A4674A,WA29040A,etc.

Stryker:502-104-030,etc.

Richard Wolf:8964.401,8645.403,etc.

Smith & Nephew:7205681,72202087,72205154,7208133,etc.

Aesculap:PE610A,PE485A,etc.

Conmed:HD4300

 

Subject of Training:

1.The structure,function,brands for rigid scope

2.Fault judgment and detection method of arthroscope

3.Rigid scope disassembly & assembly teaching

4.Practice to disassemble & assemble

5.Internal structure teaching & disassembly & assembly

6.Rod lens disassembly and debugging

7.Practise to rod lens debugging

8.Summary &Practise

9.Inner &outer tube and fiber disaasembly & assembly Teacing

10.Practice to Inner &outer tube and fiber disaasembly & assembly

11.Adjust the image, Fault judgement, Practice

Bending Rubber For Olympus BF-P290 Bronchovideoscope

$0.00

► Brief Description

 The Bending Rubber is the flexible, protective sheath covering the movable part of the scope just behind the distal tip.

► Features

  • Enables Angulation (Bending): The material and design allow the distal tip of the scope to be articulated (bent) up to 210° Up and 130° Down, which is critical for steering the scope into specific bronchial segments.
  • Enhanced Access to Upper Lobes: The 210° upward angulation is a key feature, making it smoother and easier to navigate into the typically challenging upper lobe bronchi.
  • Protection: It acts as a protective, flexible, and waterproof seal for the delicate internal components (like the CCD camera, light guides, and instrument channels) housed within the distal tip and bending section.
  • Durability and Biocompatibility: The rubber/polymer material is designed to be highly flexible, durable, and resistant to chemicals used in cleaning and high-level disinfection (HLD) processes, ensuring patient safety and device longevity.

► Specification

Brand Olympus
Model BF-P290
Series Bending Rubber
Condition Brand new
Up 210°
Down 130°
Distal End Outer Diameter 4.2 mm
Insertion Tube Outer Diameter 4.1mm
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Bending Rubber For Olympus CF-H290L Colonovideoscope

$0.00

► Brief Description

For the Olympus CF-H290L colonoscope, the bending rubber is a critical component of the bending section assembly. Its primary purpose is to provide a flexible, waterproof barrier that protects the internal mechanics while allowing for complex maneuvers.

► Features

  • Fluid Invasion Prevention
  • Maneuverability Support
  • Responsive Insertion Technology (RIT) Integration
  • Biocompatibility & Safety
  • Structural Integrity

► Specification

Brand Olympus
Model CF-H290L
Condition Brand new
Series Bending Rubber
Material Medical-grade Synthetic Rubber
Distal End Diameter 12.2 mm
Insertion Tube Diameter 12.0 mm
Standard Length Approx. 180 mm to 190 mm
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

► More service

Spare parts for flexible endoscope: insert tube, wires,helix tube,coil pipe,C-cover,glass for CCD,glass for light bundle,objective lens for CCD,drive board for CCD,light guide tube, light bundle,forcep tube, bending section, rubber, air&water tube, CCD, light source, processor, monitor, etc.

Bending Rubber For Olympus CF-HQ190L colonovideoscope

$0.00

► Brief Description

The “bending rubber” (also commonly called the rubber boot, bending boot, or angulation section sheath) on the Olympus CF-HQ190L colonovideoscope is a critical external component that covers and protects the intricate mechanism of the bending section.

► Features

  • Protective Sealing (Primary Function)
  • Facilitating Bending Movement
  • Biocompatibility and Safety
  • Infection Control

► Specification

Brand Olympus
Model CF-HQ190L
Condition Brand new
Series Bending Rubber
Material Medical-grade Silicone/Rubber
Outer Diameter (OD) Approximately 12.0 mm
Flexibility High Flexibility and Elasticity
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

► More service

Spare parts for flexible endoscope: insert tube, wires,helix tube,coil pipe,C-cover,glass for CCD,glass for light bundle,objective lens for CCD,drive board for CCD,light guide tube, light bundle,forcep tube, bending section, rubber, air&water tube, CCD, light source, processor, monitor, etc.

Bending Rubber Section For Olympus BF-1TQ290 Video Bronchoscope

$0.00

► Brief Description

For the Olympus BF-1TQ290 therapeutic video bronchoscope, the bending rubber is a critical component that ensures flexibility and maintains the scope’s waterproof integrity.

► Features

  • Hermetic Sealing (Waterproofing): It creates a liquid-tight barrier for the distal bending mechanism. This prevents water, blood, or chemical disinfectants from entering the internal assembly, which would otherwise damage the CCD image sensor or corrode the angulation wires.
  • Structural Flexibility: The rubber is engineered with a specific elasticity to allow the scope to reach its maximum angulation (180° up) without bunching or creating excessive resistance (torque) on the control wires.
  • Patient Safety (Biocompatibility): As a patient-contacting surface, the rubber is made from medical-grade materials that are non-toxic, non-irritating, and resistant to the friction encountered during insertion into the bronchial tree

► Specification

Brand Olympus
Model BF-1TQ290
Condition Brand new
Series Bending Rubber Section
Outer Diameter (OD) Approx 6.0 mm
Distal End Diameter 5.9 mm
Standard Length Approximately 100 mm – 110 mm
Angulation Range Up: 180° / Down: 130°
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Bending Rubber Section For Olympus CF-H190L Colonoscope

$0.00

► Brief Description

For the Olympus CF-H190L (Adult Colonoscope), the Bending Section Rubber is a precision-engineered protective sleeve. In a colonoscope, this component is subject to high mechanical stress due to the long insertion tube and the frequent “looping” encountered in the colon.

► Features

  • Hermetic Sealing and Waterproofing
  • Support for Responsive Insertion Technology (RIT)
  • Patient Safety and Atraumatic Navigation
  • Electrical Dielectric Insulation
  • Mechanical Recoil and Flexibility

► Specification

Brand Olympus
Model CF-H190L
Condition Brand new
Series Bending Rubber
Material Durable Synthetic Rubber
Outer Diameter (OD) Approx.12.8 mm to 13.2 mm
Wall Thickness Approx. 0.35 mm – 0.5 mm
Angulation Capability Supports Up/Down: 180°, Left/Right: 160°
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Bending Rubber Section For Olympus CF-HQ190L Colonoscope

$0.00

► Brief Description

The Bending Section Rubber (also known as the Bending Rubber Boot or Sheath) for the Olympus CF-HQ190L Colonoscope is a crucial protective and sealing component.

► Features

  • Waterproof Sealing (Leak Prevention)
  • Protection of Internal Mechanics
  • Flexibility and Angulation
  • Biocompatibility and Safety

► Specification

Brand Olympus
Model CF-HQ190L
Condition Brand new
Series Bending Rubber
Material Durable Synthetic Rubber
Inner Diameter (ID) 12.2 mm
Outer Diameter (OD) 12.8 mm
Length (L) Approximately 185 mm
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Bending Rubber Section For Olympus GIF-1TH190 Gastroscope

$0.00

â–º Brief Description

The Olympus GIF-1TH190 is a specialized therapeutic gastroscope from the EVIS EXERA III series. The Bending Section Rubber is a critical component that protects the internal mechanisms while maintaining flexibility.

► Features

  • Fluid Tightness (Hermetic Seal): Its most critical job is to prevent water, gastric juices, and cleaning chemicals from entering the internal “neck” of the scope. If the rubber is breached, the internal wires and the CCD/CMOS image sensor will suffer “fluid invasion,” leading to expensive repairs.
  • Structural Flexibility: It must expand and contract smoothly as the pull-wires move the bending vertebrae. It provides the “rebound” or tension necessary for the scope to return to a neutral position.
  • Patient Protection: The rubber provides a smooth, seamless cover over the metal “vertebrae” (the skeleton) of the bending section, preventing internal mechanical parts from pinching or traumatizing the patient’s esophagus or stomach lining.
  • Dielectric Insulation: During electrosurgical procedures (like EMR or ESD), the rubber acts as an insulator, ensuring that high-frequency current does not leak from the scope to the patient’s tissue in unintended areas.

 

► Specification

Brand Olympus
Model GIF-1TH190
Condition Brand new
Series Bending Rubber
Material Durable fluoropolymer rubber
Outer Diameter (OD) Approx 10.0 mm to 10.9 mm
Wall Thickness Approx. 0.2 mm – 0.4 mm
Elasticity High-tensile strength
Color Black
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

 

Bending Rubber Section For Olympus GIF-HQ190 Gastroscope

$0.00

â–º Brief Description

Bending rubber section is a key component for endoscope repair, as it maintains the waterproof seal and protects the internal angulation mechanics.

► Features

  • Protection of Internal Components
  • Biocompatibility and Safety
  • Sealing (Waterproofing)
  • Flexibility and Angulation

► Specification

Brand Olympus
Model GIF-HQ190
Condition Brand new
Series Bending Rubber
Material Durable fluoropolymer rubber
Inner Diameter (ID) 9.4 mm
Length (L) Approximately 110 mm
Wall Thickness (WT) Approximately 1.2 mm
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Bending Section Assembly For Olympus BF-1TQ290 Video Bronchoscope

$0.00

► Brief Description

For the Olympus BF-1TQ290 therapeutic video bronchoscope, the Bending Section Assembly is the high-precision internal framework that enables steerability and protects the scope’s distal internal components.

► Features

  • Precision Angulation (Steering)
  • Internal Component Protection
  • Structural Support for the Bending Rubber
  • Device Passage Stabilization

► Specification

Brand Olympus
Model BF-1TQ290
Condition Brand new
Series Bending Section Assembly
Distal End Diameter 5.9 mm
Insertion Tube OD 6.0 mm
Angulation Range Up 180° / Down 130°
Instrument Channel ID 3.0 mm
Material Construction Stainless Steel
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Bending Section Assembly for Olympus BF-P290 Video Bronchoscope

$0.00

► Brief Description

The Bending Section Assembly for the Olympus BF-P290 Bronchoscope is integral to the scope’s maneuverability, especially in reaching peripheral areas of the lung.

► Features

  • Steering and Articulation Converts the rotation of the angulation knobs (on the control body) into Up and Down movement of the distal tip.
  • Enhanced Maneuverability Facilitates the exceptionally wide 210°Up  and 130° down angulation range.
  • Protection and SealingThe assembly’s mesh and surrounding bending rubber protect the delicate internal components (CCD wiring, light guide fibers, and working channel) from internal and external damage.
  • Accessory Alignment Directs the exit and entry point of therapeutic and diagnostic instruments (passed through the 2.0 mm working channel) toward the area of interest at the end of the bend.

► Specification

Brand Olympus
Model CF-H290L
Series Bending Section Assembly
Material Stainless steel
Up 210°
Down 130°
Distal End Outer Diameter 4.2 mm
Working Channel Diameter 2.0 mm
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Fix Once Right, Save Replacement Costs

Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.

However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.

Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.

If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!