Stryker

Showing all 8 results

Brand New Cable Stryker 5100-4/5100-004-000 For Drills

► Brief Description

The item Stryker 5100-4 (or 5100-004-000) is a crucial component in Stryker’s surgical power equipment, specifically a Handpiece Cord used to connect various drills and motorized instruments to the control console, it is integral to the functionality of the drill and saw systems.

► Features

  • Delivers electrical power from the main control console (e.g., the CORE™ or TPS console) to the surgical handpiece (the drill or saw).
  • Transmits digital and electrical signals between the handpiece and the console. This includes signals from the foot pedal or hand switch.
  • Provides a secure, sealed, and keyed connection to both the handpiece and the console port.

► Specification

Brand Stryker
Model 5100-4/5100-004-000
Condition Brand new
Series Handpiece cable
Length (Approx.) 12 feet (3.66 meters)
Compatibility Broad Compatibility
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

High Quality Dust Shield For OLYMPUS/ WOLF/STORZ/Stryker/Smith&Nephew/CONMED Camera Head

► Brief Description

In a surgical setting, it is a standard “best practice” to never leave a camera head uncovered. If the endoscope is removed, the dust cap should be applied immediately to prevent “fogging” or contamination from the operating room environment.the parameters and functions are centered around maintaining optical sterility and mechanical integrity.

► Features

  • Sensor & Lens Protection
  • Contamination Prevention
  • Maintenance of Optical Clarity
  • Mechanical Integrity (Connection Points)
  • Sterilization Readiness

► Specification

Brand OLYMPUS/ WOLF/STORZ/Stryker/Smith&Nephew/CONMED
Condition Brand new
Series Dust Shield
Compatibility General/Almost all cameras
Material Peek material
Temperature Resistance Autoclavable
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Medical Equipment Repair Certification Course Of Rigidscope Training For Client From Saudi Arabia

Medical Equipment Repair Certification Course Of Rigidscope Training For Client From Saudi Arabia

The courses we organize and their contents are as follows.

COURSE:

Rigid scope Repair Training Course

Brands:

KARL STORZ,Olympus,Stryker,Richard Wolf,Smith & Nephew,Aesculap,Conmed

Duration:

5 Days / 4 hours per day (20 hours total)

Course Schedule:

Courses run on demand. We open the course when you ask for it and arrange the dates together with you.

Instructor:

Experienced Medical Device Repair Specialist.

Training Models:

KARL STORZ: 26003BA,26033BA,26605BA,27005BA, 7230AA,7230BA,26046BA,26046AA,etc.
Olympus: WA53005A,WA53000A,WA50373B,WA50372B,WA2T430A,A4674A,WA29040A,etc.

Stryker:502-104-030,etc.

Richard Wolf:8964.401,8645.403,etc.

Smith & Nephew:7205681,72202087,72205154,7208133,etc.

Aesculap:PE610A,PE485A,etc.

Conmed:HD4300

Subject of Training:

1.The structure,function,brands for rigid scope

2.Fault judgment and detection method of arthroscope

3.Rigid scope disassembly & assembly teaching

4.Practice to disassemble & assemble

5.Internal structure teaching & disassembly & assembly

6.Rod lens disassembly and debugging

7.Practise to rod lens debugging

8.Summary &Practise

9.Inner &outer tube and fiber disaasembly & assembly Teacing

10.Practice to Inner &outer tube and fiber disaasembly & assembly

11.Adjust the image, Fault judgement, Practice

Medical Equipment Repair Certification Course Of Storz H3-Z, the Olympus OTV-S7ProH-HD-12E, and the Olympus CH-S190-XZ-E Camera Head Training For Italy Clients

Medical Equipment Repair Certification Course Of Storz H3-Z, the Olympus OTV-S7ProH-HD-12E, and the Olympus CH-S190-XZ-E Camera Head Training For Italy Clients

The courses we organize and their contents are as follows.

COURSE:

Storz H3-Z, Olympus OTV-S7ProH-HD-12E/ CH-S190-XZ-E Camera Head Repair Training Course

Brands:

OLYMPUS, WOLF, STORZ, Stryker, Smith&Nephew, etc.

 

Duration:

5 Days / 4 hours per day (20 hours total)

Course Schedule:

Courses run on demand. We open the course when you ask for it and arrange the dates together with you.

Instructor:

Experienced Medical Device Repair Specialist.

Training Models:

OLYMPUS:OTV-S4,OTV-S5,OTV-SX2,OTV-SC,OTV-S6,OTV-S7,CV-165

WOLF:5502,5506,5507,5509,5512,5516,5525,5550

STORZ:22201020,20242020,22202022,20212020

Stryker:888i,988i,1088/1088HD,1188/1188HD,1288/1288HD,1488/1488HD,1588/1588HD,1688/1688HD

Smith&Nephew:460P,560P,ED-3,325Z,350

 

Subject of Training:

1.Common brands of camera head , applications and faults

2.Disassembly and Assembly of Camera head and Tools

3.Detection methods and fault diagnosis of Camera head

4.Camera detection and practical operation of tool usage

5.Cable Detection method of Storz H3-Z

6.Cable Disassembly and Wiring of Storz H3-Z

7.Cable Maintenance Practical Operation of Storz H3-Z

8.Disassembly and Installation of OTV-S7ProH-HD-12E

9.Cable Detection method of OTV-S7ProH-HD-12E

10.Cable repair for OTV-S7ProH-HD-12E

11.Cable Maintenance Practical Operation of OTV-S7ProH-HD-12E

12.Disassembly and Installation of CH-S190-XZ-E

13.Cable Detection method of CH-S190-XZ-E

14.Cable Disassembly and Wiring of CH-S190-XZ-E

15.Cable Maintenance Practical Operation of CH-S190-XZ-E

Stryker 1188-210-105 camera head for repair

► Brief Description

Fault: Image with interrupt. Cable aging.

Solution: Replace compatible new cable and connector.

►Problem & Solutoin

Brand STRYKER
Model 1188-210-105
Fault Image with interrupt. Cable aging
Solution Replace compatible new cable and connector

► Common issues with 1188-210-105 camera head

  • Image Quality Problems
  • Physical and Cable Damage
  • Button and Control Malfunctions
  • Overheating

Stryker 1188-210-105 HD 3-Chip Camera Head

► Brief Description

The Stryker 1188-210-105 is a vital component of an operating room’s video endoscopy setup, enabling surgeons to visualize internal anatomy during complex procedures.

► Features

  • Provides native output resolution of 1280 x 1024 (SXGA), delivering sharp, detailed images for superior visualization.
  • Utilizes three CCDs (Charge-Coupled Devices) to ensure excellent color fidelity and high-quality image capture.
  • Lightweight and ergonomic design with a textured finish, ideal for secure and comfortable handling during minimally invasive procedures.
  • Features a camera head button (cross-shaped keypad) with four fully programmable buttons that offer six functions for complete surgeon control.
  • Employs 10-bit digital processing for optimal clarity and improved signal-to-noise ratio.
  • Uses Progressive Scan Technology for clearer images and reduced motion artifacts compared to interlaced. scanning.
  • Includes 9 specialty settings (e.g., Arthroscopy, Laparoscopy, Hysteroscopy) to allow for surgical standardization and optimal imaging parameters based on the procedure.

► Specification

Brand Stryker
Model 1188-210-105
Condition Working in Good Condition
Series Camera Head
Resolution 1280 x 1024 (SXGA) native output
Imaging System 1/3″ Progressive Scan CCDs, High Definition
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Stryker 30º 0502-503-030 laproscope for repair

► Brief Description

Fault:

Image blur, objective lens loose without glue, inner optical parts broken.

Solution:

Add glue for objective lens, replace inner optical parts, clean and adjust optical system, seal with eyepiece.

►Problem & Solutoin

Brand Stryker
Model 0502-503-030
Fault Image blur, objective lens loose without glue, inner optical parts broken.
Solution Add glue for objective lens, replace inner optical parts, clean and adjust optical system, seal with eyepiece.

► Common issues with 0502-503-030 laproscope

  • Image Quality Issues
  • Physical Damage
  • Light Transmission Problems
  • Fluid or Gas Leaks

Stryker Formula 180 Shaver Handpiece 375-708-500

► Brief Description

The Stryker 375-708-500 is the Stryker Formula 180 Shaver Handpiece. It is a medical device used primarily in arthroscopic surgery.

► Features

  • Intended Use/Discipline: Orthopedics, specifically for Arthroscopic Surgery.
  • Purpose: Used for tissue resection, cutting, shaving, and removal of soft and hard tissue (like cartilage or meniscal tissue) inside a joint.
  • Operating Mode: Features an Oscillating function in addition to forward and reverse rotation modes, which is essential for efficient tissue shaving.
  • Control: It is a Hand Controlled handpiece, meaning it includes buttons on the handpiece itself to allow the surgeon to directly control speed and/or operating mode without sole reliance on a foot pedal.

► Specification

Brand Stryker
Model 375-708-500
Condition Working in Good Condition
Series Shaver Handpiece
Power Type Electric/Powered
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Fix Once Right, Save Replacement Costs

Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.

However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.

Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.

If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!