Bending Section Assemblies For FUJIFILM Flexible Endoscope (Assorted Diameters)
Apple Shopping Event
Hurry and get discounts up to 20% Read more
Bending Section Assemblies For FUJIFILM Flexible Endoscope (Assorted Diameters)
Cleaned and inspected FUJIFILM flexible endoscope bending section / coil pipe assemblies in assorted diameters, photo-matched to your scope before dispatch.
- Mixed-diameter workshop assortment – not one model-specific numbered part
- Matched by scope model, measured outer diameter and distal-ring photo
- Compatible repair part, no factory FUJIFILM part number
- Bending rubber, mesh, wires and distal head sold separately
All new aftermarket parts come with a 1-Year warranty. Quality is the first thing we consider. Check out our Warranty Assistance for more details.
All expedited shipping so you can get your medical machine back in action, fast. Check out our Shipping Policy for more details.
We prioritize your satisfaction. If your order doesn't meet your expectations within 90 days, you may be eligible for a refund. See our Easy Return Policy for details.
Description
Bending Section Assemblies For FUJIFILM Flexible Endoscope (Assorted Diameters)
► Brief Description
The bending section is the articulated distal assembly that lets the endoscopist steer the tip: interlocking metal rings, a braided mesh, angulation wires and a sealed rubber cover, with the distal metal ring and the wire terminations at the tip. When the rings deform, a wire snaps or the mesh corrodes after a leak, the whole assembly is normally replaced rather than repaired in place.
The photos show a mixed batch of FUJIFILM flexible endoscope bending section / coil pipe assemblies in several diameters, laid out so the distal metal rings, the wire tails and the proximal coupling ends can be compared. We supply them as an assorted, photo-matched assortment for workshops that service more than one Fujifilm scope generation and want the right diameter on the bench without ordering a full numbered assembly for every job.
Please note – read before ordering: these are cleaned and inspected compatible assemblies without a manufacturer part number, not factory-sealed FUJIFILM spares. They are not sorted by a single scope model. Fujifilm 200 / 400 / 500 / 600 / 700 series scopes use different diameters and wire layouts, so please send the model from the scope nameplate, the outer diameter of your old bending section measured with a caliper, and a close-up of the distal ring with a ruler beside it. We will match the assembly from the photos before dispatch. This listing is the bending section / coil pipe only – bending rubber, braided mesh, angulation wire and distal head are separate items.
► Features
- Assorted diameters: a mixed batch of FUJIFILM bending section / coil pipe assemblies, as shown in the photos.
- Photo-matched before dispatch: confirm model, outer diameter and distal ring profile against your old part so the correct assembly is supplied.
- Complete articulated structure: interlocking rings with wire tails and distal metal ring, ready to be built into the distal end.
- Restores 4-way angulation: replaces a deformed, kinked or corroded section that has lost tip deflection or will not hold its position.
- Workshop assortment: useful for repair labs servicing several Fujifilm gastroscope / colonoscope generations.
- Repair support: we also supply the matching bending rubber, mesh, angulation wire, light bundles and distal head, and can carry out the full repair in house.

► Specification
| Product | Bending section / coil pipe assembly assortment (repair part) |
| Brand compatibility | FUJIFILM flexible endoscopes (gastroscopes / colonoscopes) |
| Type | Assorted diameters – not sorted to a single scope model |
| Construction | Interlocking metal rings, angulation wire tails, distal metal ring |
| Matching method | By scope model + measured outer diameter + close-up photo with ruler |
| Part number | None – cleaned and inspected compatible assemblies, no factory FUJIFILM number |
| Set contents | 1 assembly in the diameter confirmed before order, as pictured |
| Not included | Bending rubber, braided mesh, angulation wire, light bundles, distal head, endoscope |
| Condition | As pictured – cleaned and inspected compatible repair part |
| Installation | Professional workshop fitting and leak test required |
| Quantity | 1 assembly |
| MOQ | 1 Set |
| Package | Anti-static bag / foam + export carton |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept negotiation |
► FAQ
Which FUJIFILM scopes do these fit?
A: They are a mixed assortment rather than one model-specific part, so we match them to your scope before shipping. Send the model from the nameplate (for example an EG- or EC- series scope), the measured outer diameter of the old bending section and a photo of the distal ring with a ruler.
Why is there no part number?
A: These are cleaned and inspected compatible assemblies taken from mixed repair stock, not factory-sealed FUJIFILM spares with an original part number. If you need an original numbered assembly for a specific model, we also list model-specific bending sections – ask us and we will point you to the right listing.
What faults does a new bending section fix?
A: A distal tip that no longer returns to neutral, loss of up/down or left/right deflection, a grating or slipping angulation knob, snapped angulation wires, or a kinked coil pipe after the insertion tube was crushed. If only the rubber cover is split, the bending rubber may be enough.
Is the bending rubber / mesh / wire included?
A: No, this listing is the bending section / coil pipe assembly only. The matching bending rubber, braided mesh, angulation wires, light bundles and distal head are separate parts – ask us and we will quote them together for your model.
How do I avoid ordering the wrong diameter?
A: Measure the outer diameter of the old assembly with a caliper and send a close-up of the distal metal ring with a ruler or caliper beside it. Fujifilm series differ by only a few tenths of a millimetre, and the wire layout also varies, so the photo matters as much as the measurement.
Can you fit it for me?
A: Yes. We repair flexible Fujifilm gastroscopes and colonoscopes, replace bending sections, re-thread and tension the angulation wires, fit a new bending rubber and leak test the scope before return.
► More service
Spare parts for flexible endoscopes could be provided including: bending section, coil pipe, braided mesh, bending rubber, insertion tube, light bundle, light guide tube, CCD, CCD driver board, objective lens, distal head, nozzle, air/water tube, biopsy channel, angulation wire, control knob and buttons.
We also repair flexible gastroscopes, colonoscopes, bronchoscopes and cystoscopes, and run repair training courses for endoscope service.
For more information just contact us.
► About Us
CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.
Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.
► What we can do

Product details
In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.
Product details
In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.
Description
Bending Section Assemblies For FUJIFILM Flexible Endoscope (Assorted Diameters)
► Brief Description
The bending section is the articulated distal assembly that lets the endoscopist steer the tip: interlocking metal rings, a braided mesh, angulation wires and a sealed rubber cover, with the distal metal ring and the wire terminations at the tip. When the rings deform, a wire snaps or the mesh corrodes after a leak, the whole assembly is normally replaced rather than repaired in place.
The photos show a mixed batch of FUJIFILM flexible endoscope bending section / coil pipe assemblies in several diameters, laid out so the distal metal rings, the wire tails and the proximal coupling ends can be compared. We supply them as an assorted, photo-matched assortment for workshops that service more than one Fujifilm scope generation and want the right diameter on the bench without ordering a full numbered assembly for every job.
Please note – read before ordering: these are cleaned and inspected compatible assemblies without a manufacturer part number, not factory-sealed FUJIFILM spares. They are not sorted by a single scope model. Fujifilm 200 / 400 / 500 / 600 / 700 series scopes use different diameters and wire layouts, so please send the model from the scope nameplate, the outer diameter of your old bending section measured with a caliper, and a close-up of the distal ring with a ruler beside it. We will match the assembly from the photos before dispatch. This listing is the bending section / coil pipe only – bending rubber, braided mesh, angulation wire and distal head are separate items.
► Features
- Assorted diameters: a mixed batch of FUJIFILM bending section / coil pipe assemblies, as shown in the photos.
- Photo-matched before dispatch: confirm model, outer diameter and distal ring profile against your old part so the correct assembly is supplied.
- Complete articulated structure: interlocking rings with wire tails and distal metal ring, ready to be built into the distal end.
- Restores 4-way angulation: replaces a deformed, kinked or corroded section that has lost tip deflection or will not hold its position.
- Workshop assortment: useful for repair labs servicing several Fujifilm gastroscope / colonoscope generations.
- Repair support: we also supply the matching bending rubber, mesh, angulation wire, light bundles and distal head, and can carry out the full repair in house.

► Specification
| Product | Bending section / coil pipe assembly assortment (repair part) |
| Brand compatibility | FUJIFILM flexible endoscopes (gastroscopes / colonoscopes) |
| Type | Assorted diameters – not sorted to a single scope model |
| Construction | Interlocking metal rings, angulation wire tails, distal metal ring |
| Matching method | By scope model + measured outer diameter + close-up photo with ruler |
| Part number | None – cleaned and inspected compatible assemblies, no factory FUJIFILM number |
| Set contents | 1 assembly in the diameter confirmed before order, as pictured |
| Not included | Bending rubber, braided mesh, angulation wire, light bundles, distal head, endoscope |
| Condition | As pictured – cleaned and inspected compatible repair part |
| Installation | Professional workshop fitting and leak test required |
| Quantity | 1 assembly |
| MOQ | 1 Set |
| Package | Anti-static bag / foam + export carton |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept negotiation |
► FAQ
Which FUJIFILM scopes do these fit?
A: They are a mixed assortment rather than one model-specific part, so we match them to your scope before shipping. Send the model from the nameplate (for example an EG- or EC- series scope), the measured outer diameter of the old bending section and a photo of the distal ring with a ruler.
Why is there no part number?
A: These are cleaned and inspected compatible assemblies taken from mixed repair stock, not factory-sealed FUJIFILM spares with an original part number. If you need an original numbered assembly for a specific model, we also list model-specific bending sections – ask us and we will point you to the right listing.
What faults does a new bending section fix?
A: A distal tip that no longer returns to neutral, loss of up/down or left/right deflection, a grating or slipping angulation knob, snapped angulation wires, or a kinked coil pipe after the insertion tube was crushed. If only the rubber cover is split, the bending rubber may be enough.
Is the bending rubber / mesh / wire included?
A: No, this listing is the bending section / coil pipe assembly only. The matching bending rubber, braided mesh, angulation wires, light bundles and distal head are separate parts – ask us and we will quote them together for your model.
How do I avoid ordering the wrong diameter?
A: Measure the outer diameter of the old assembly with a caliper and send a close-up of the distal metal ring with a ruler or caliper beside it. Fujifilm series differ by only a few tenths of a millimetre, and the wire layout also varies, so the photo matters as much as the measurement.
Can you fit it for me?
A: Yes. We repair flexible Fujifilm gastroscopes and colonoscopes, replace bending sections, re-thread and tension the angulation wires, fit a new bending rubber and leak test the scope before return.
► More service
Spare parts for flexible endoscopes could be provided including: bending section, coil pipe, braided mesh, bending rubber, insertion tube, light bundle, light guide tube, CCD, CCD driver board, objective lens, distal head, nozzle, air/water tube, biopsy channel, angulation wire, control knob and buttons.
We also repair flexible gastroscopes, colonoscopes, bronchoscopes and cystoscopes, and run repair training courses for endoscope service.
For more information just contact us.
► About Us
CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.
Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.
► What we can do

Customer Reviews
Related Products
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!

Reviews
Clear filtersThere are no reviews yet.