Camera Head Cable Assembly For KARL STORZ TIPCAM 1 S 3D LAP 26605BA
Apple Shopping Event
Hurry and get discounts up to 20% Read more
Camera Head Cable Assembly For KARL STORZ TIPCAM 1 S 3D LAP 26605BA
Brand new replacement camera cable assembly for the KARL STORZ TIPCAM 1 S 3D LAP 26605BA 30° 3D videoendoscope. 300 cm sealed D3-LINK lead with console plug and round telescope-side connector.
- For IMAGE1 S 3D / TC302 D3-LINK – 26605BA (30°) and 26605AA (0°)
- Fixes intermittent 3D video from a broken conductor or damaged console pin
- Compatible replacement cable only – the complete telescope is NOT included
- Professional fitting, insulation and leak test required
All new aftermarket parts come with a 1-Year warranty. Quality is the first thing we consider. Check out our Warranty Assistance for more details.
All expedited shipping so you can get your medical machine back in action, fast. Check out our Shipping Policy for more details.
We prioritize your satisfaction. If your order doesn't meet your expectations within 90 days, you may be eligible for a refund. See our Easy Return Policy for details.
Description
Camera Head Cable Assembly For KARL STORZ TIPCAM 1 S 3D LAP 26605BA
► Brief Description
The 26605BA is the KARL STORZ TIPCAM®1 S 3D LAP, 30° 3D videoendoscope for the IMAGE1 S™ 3D platform. Two distal CMOS sensors deliver stereoscopic Full HD (1920 x 1080) images, and the telescope is joined to the camera control unit by a sealed, non-detachable 300 cm D3-LINK® cable. Because that cable cannot simply be unplugged, a crushed jacket, a bent contact in the console plug or a conductor breaking at the strain relief normally means the whole 3D laparoscope is quoted for replacement.
This listing is the replacement camera cable assembly used in our workshop to repair that fault – not the complete 3D laparoscope. One end carries the D3-LINK console plug with its gold contact row and retaining strap; the other end is the round camera-side connector whose pin face is shown in the photos. It is supplied coiled and protected in a foam-lined box so the plugs are not crushed in transit.
Typical symptoms are a 3D image that drops one channel, intermittent video when the lead is flexed near the head, or a damaged pin in the console plug. Fitting requires opening and re-sealing the telescope handle, terminating the conductors and running an insulation and leak check afterwards. If you do not have the facilities, send us the scope and we can do the cable replacement for you.
Please note: this is a compatible replacement cable assembly, not a factory-sealed KARL STORZ spare part and not the complete 26605BA videoendoscope. Confirm the plug and the head variant with a photo before ordering. The 250 cm D3-LINK extension cable (TC015) is a separate item and is not included; the VITOM® 3D (TH200) is not compatible.
► Features
- For the IMAGE1 S 3D platform: suits the TIPCAM 1 S 3D LAP 26605BA / 26605AA 30° 3D videoendoscope with the D3-LINK camera cable.
- D3-LINK console plug fitted: gold contact row and hinged retaining strap at the camera control unit end, ready to mate with the TC302 D3-LINK module.
- Round camera-side connector: multi-pin plug at the telescope handle end, pin face photographed separately for matching.
- 300 cm sealed lead: matches the original non-detachable cable length and routing.
- Repairs intermittent 3D video: the usual fix for a broken conductor at the strain relief, a damaged jacket or a bent console pin.
- Workshop support: we can supply connection notes, or fit the cable and leak test the telescope in our own repair lab.

► Specification
| Product | Camera head / video cable assembly (repair part) |
| Compatible videoendoscope | KARL STORZ TIPCAM 1 S 3D LAP, 30°, item no. 26605BA (also 26605AA 0°) |
| Platform | IMAGE1 S 3D – TC200 CONNECT with TC302 D3-LINK module |
| Head specification | 2 x distal CMOS, Full HD 1920 x 1080, 50/60 Hz progressive, stereoscopic 3D |
| Telescope | 10.3 mm outer diameter, 320 mm working length, 30° direction of view, 420 g |
| Cable | 300 cm, straight routing, non-detachable, D3-LINK |
| Console connector | D3-LINK plug with gold contact row and retaining strap |
| Telescope-side connector | Round multi-pin plug, pin face as pictured |
| Imaging technologies | CLARA, CHROMA, SPECTRA A + B; 3D / 2D toggle; 3 head buttons (2 programmable) |
| Sterilisation | Autoclavable, H2O2 compatible |
| Not included | Complete 26605BA telescope, TC015 250 cm extension cable, TC302 module |
| Not compatible with | VITOM 3D TH200 |
| Condition | Brand new compatible replacement cable, not an original KARL STORZ spare |
| Installation | Professional workshop fitting, insulation and leak test required |
| Quantity | 1 cable assembly |
| MOQ | 1 Set |
| Package | Anti-static bag / foam + export carton |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept negotiation |
► FAQ
Which system does this cable fit?
A: The KARL STORZ TIPCAM 1 S 3D LAP 30° (26605BA) and the 0° variant 26605AA, used on the IMAGE1 S 3D platform with a TC200 CONNECT and a TC302 D3-LINK module. It is not for the VITOM 3D TH200 or for 2D IMAGE1 heads.
Is this the complete 3D laparoscope?
A: No. This is the replacement camera cable assembly only. The telescope, optics, CMOS sensors and handle are not included. The photos show the cable and its two plugs, not the telescope shaft.
Is the cable detachable on the 26605BA?
A: No. The 300 cm D3-LINK lead is sealed into the videoendoscope, so replacing it means opening the handle, terminating the conductors and re-sealing the housing. That is workshop work, not a user-replaceable accessory.
How do I know the cable is the fault?
A: Typical signs are losing one of the two 3D channels, an image that flickers or drops out when the lead is flexed near the strain relief, a bent or corroded pin in the console plug, or visible damage to the jacket. A stable head on a bench system with an intermittent lead points to the cable.
Is the extension cable included?
A: No. The 250 cm IMAGE1 S D3-LINK extension cable (TC015) is a separate KARL STORZ item. Ask us if you need it quoted together. Please also send a close-up of your console plug so we can confirm the connector housing before shipping.
Can you fit it for me?
A: Yes. Send the videoendoscope in and we will replace the cable, re-seal and leak test the handle, then bench-test both 3D channels before return.
► More service
Spare parts for camera system could be provided including: camera head cable, CCD module, front lens, focusing ring, focusing lens, coupler, light guide adaptor, camera head buttons, dust shield, socket connectors, internal seals and repair tools.
We also repair camera heads and camera control units, and run repair training courses for camera system service.
For more information just contact us.
► About Us
CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.
Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.
► What we can do

Product details
In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.
Product details
In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.
Description
Camera Head Cable Assembly For KARL STORZ TIPCAM 1 S 3D LAP 26605BA
► Brief Description
The 26605BA is the KARL STORZ TIPCAM®1 S 3D LAP, 30° 3D videoendoscope for the IMAGE1 S™ 3D platform. Two distal CMOS sensors deliver stereoscopic Full HD (1920 x 1080) images, and the telescope is joined to the camera control unit by a sealed, non-detachable 300 cm D3-LINK® cable. Because that cable cannot simply be unplugged, a crushed jacket, a bent contact in the console plug or a conductor breaking at the strain relief normally means the whole 3D laparoscope is quoted for replacement.
This listing is the replacement camera cable assembly used in our workshop to repair that fault – not the complete 3D laparoscope. One end carries the D3-LINK console plug with its gold contact row and retaining strap; the other end is the round camera-side connector whose pin face is shown in the photos. It is supplied coiled and protected in a foam-lined box so the plugs are not crushed in transit.
Typical symptoms are a 3D image that drops one channel, intermittent video when the lead is flexed near the head, or a damaged pin in the console plug. Fitting requires opening and re-sealing the telescope handle, terminating the conductors and running an insulation and leak check afterwards. If you do not have the facilities, send us the scope and we can do the cable replacement for you.
Please note: this is a compatible replacement cable assembly, not a factory-sealed KARL STORZ spare part and not the complete 26605BA videoendoscope. Confirm the plug and the head variant with a photo before ordering. The 250 cm D3-LINK extension cable (TC015) is a separate item and is not included; the VITOM® 3D (TH200) is not compatible.
► Features
- For the IMAGE1 S 3D platform: suits the TIPCAM 1 S 3D LAP 26605BA / 26605AA 30° 3D videoendoscope with the D3-LINK camera cable.
- D3-LINK console plug fitted: gold contact row and hinged retaining strap at the camera control unit end, ready to mate with the TC302 D3-LINK module.
- Round camera-side connector: multi-pin plug at the telescope handle end, pin face photographed separately for matching.
- 300 cm sealed lead: matches the original non-detachable cable length and routing.
- Repairs intermittent 3D video: the usual fix for a broken conductor at the strain relief, a damaged jacket or a bent console pin.
- Workshop support: we can supply connection notes, or fit the cable and leak test the telescope in our own repair lab.

► Specification
| Product | Camera head / video cable assembly (repair part) |
| Compatible videoendoscope | KARL STORZ TIPCAM 1 S 3D LAP, 30°, item no. 26605BA (also 26605AA 0°) |
| Platform | IMAGE1 S 3D – TC200 CONNECT with TC302 D3-LINK module |
| Head specification | 2 x distal CMOS, Full HD 1920 x 1080, 50/60 Hz progressive, stereoscopic 3D |
| Telescope | 10.3 mm outer diameter, 320 mm working length, 30° direction of view, 420 g |
| Cable | 300 cm, straight routing, non-detachable, D3-LINK |
| Console connector | D3-LINK plug with gold contact row and retaining strap |
| Telescope-side connector | Round multi-pin plug, pin face as pictured |
| Imaging technologies | CLARA, CHROMA, SPECTRA A + B; 3D / 2D toggle; 3 head buttons (2 programmable) |
| Sterilisation | Autoclavable, H2O2 compatible |
| Not included | Complete 26605BA telescope, TC015 250 cm extension cable, TC302 module |
| Not compatible with | VITOM 3D TH200 |
| Condition | Brand new compatible replacement cable, not an original KARL STORZ spare |
| Installation | Professional workshop fitting, insulation and leak test required |
| Quantity | 1 cable assembly |
| MOQ | 1 Set |
| Package | Anti-static bag / foam + export carton |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept negotiation |
► FAQ
Which system does this cable fit?
A: The KARL STORZ TIPCAM 1 S 3D LAP 30° (26605BA) and the 0° variant 26605AA, used on the IMAGE1 S 3D platform with a TC200 CONNECT and a TC302 D3-LINK module. It is not for the VITOM 3D TH200 or for 2D IMAGE1 heads.
Is this the complete 3D laparoscope?
A: No. This is the replacement camera cable assembly only. The telescope, optics, CMOS sensors and handle are not included. The photos show the cable and its two plugs, not the telescope shaft.
Is the cable detachable on the 26605BA?
A: No. The 300 cm D3-LINK lead is sealed into the videoendoscope, so replacing it means opening the handle, terminating the conductors and re-sealing the housing. That is workshop work, not a user-replaceable accessory.
How do I know the cable is the fault?
A: Typical signs are losing one of the two 3D channels, an image that flickers or drops out when the lead is flexed near the strain relief, a bent or corroded pin in the console plug, or visible damage to the jacket. A stable head on a bench system with an intermittent lead points to the cable.
Is the extension cable included?
A: No. The 250 cm IMAGE1 S D3-LINK extension cable (TC015) is a separate KARL STORZ item. Ask us if you need it quoted together. Please also send a close-up of your console plug so we can confirm the connector housing before shipping.
Can you fit it for me?
A: Yes. Send the videoendoscope in and we will replace the cable, re-seal and leak test the handle, then bench-test both 3D channels before return.
► More service
Spare parts for camera system could be provided including: camera head cable, CCD module, front lens, focusing ring, focusing lens, coupler, light guide adaptor, camera head buttons, dust shield, socket connectors, internal seals and repair tools.
We also repair camera heads and camera control units, and run repair training courses for camera system service.
For more information just contact us.
► About Us
CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.
Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.
► What we can do

Customer Reviews
Related Products
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!

Reviews
Clear filtersThere are no reviews yet.