1-Core Button Switch For Olympus GIF-HQ290 Gastroscope Control Section Repair Part

Apple Shopping Event

Hurry and get discounts up to 20% Read more

1-Core Button Switch For Olympus GIF-HQ290 Gastroscope Control Section Repair Part

New 1-core button switch with lead wire for the Olympus GIF-HQ290 control section. Replace a single dead or intermittent key without changing the whole button strip or control board.

  • Single pole push button, 1 core, solder termination
  • Fits the moulded seat under the GIF-HQ290 button cover
  • New, unused switch with clean contacts and full-length leads
  • Photo matching available before shipping

Warranty Policy

All new aftermarket parts come with a 1-Year warranty. Quality is the first thing we consider. Check out our Warranty Assistance for more details.

Shipping Policy

All expedited shipping so you can get your medical machine back in action, fast. Check out our Shipping Policy for more details.

Easy Return Policy

We prioritize your satisfaction. If your order doesn't meet your expectations within 90 days, you may be eligible for a refund. See our Easy Return Policy for details.

Description

1-Core Button Switch For Olympus GIF-HQ290 Gastroscope Control Section Repair Part

► Brief Description

The control section of the GIF-HQ290 carries a row of small push buttons under the rubber cover: image freeze, insufflation/aspiration selection and the programmable keys. Each one is a single-core micro switch with a short lead that is soldered to the control board and held in a moulded seat under the cover.

These switches fail in two ways. Mechanically, the plunger wears or the contact oxidises so the button needs a hard press, works intermittently, or stops responding altogether. And because the switch sits under the rubber cover, a split cover lets cleaning fluid and disinfectant reach the contacts, which corrodes them and can track along the lead into the control board.

We supply the replacement as a new, unused 1-core button switch with lead wire, as shown in the photos. If only one key has stopped working there is no need to replace the whole control board or the button strip assembly — this single switch is the part to change.

► Features

  • 1-core push button: single pole, normally open, with lead wire ready to solder to the control board.
  • For the GIF-HQ290 control section: fits the moulded seat under the button cover, same height as the original so the rubber cover sits flat.
  • New, unused: clean contacts, no solder residue or pulled leads.
  • Single-key repair: replace one failed button without buying the full button strip or the control board.
  • Photo matching: send a close-up of your old switch with the lead direction visible and we will confirm the type before shipping.
  • Repair support: we also service GIF-HQ290 control sections, including cover replacement and board-level repair.

1-core button switches for Olympus GIF-HQ290 gastroscope control section One core button switch with lead wire for Olympus GIF-HQ290 gastroscope Single core push button switch for Olympus endoscope control section Olympus GIF-HQ290 button switches in sealed package

► Specification

Product 1-core button switch with lead wire
Application OLYMPUS GIF-HQ290 gastroscope control section
Switch type Single pole push button, 1 core
Termination Solder, lead wire attached
Mounting Moulded seat under the control section button cover
Function Freeze / insufflation-aspiration selection / programmable key
Condition Brand new
Quantity 1 piece
MOQ 1 Piece
Package Anti-static bag / foam + export carton
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept negotiation

► FAQ

How many switches do I need?

A: One switch per key. If a single button has stopped responding, one piece is enough. If several keys are dead, check the lead and the control board first, because the fault may be at the board end.

Is the rubber button cover included?

A: No, this listing is the switch only. We can supply the cover separately, and if the cover is split that is usually why the switch corroded in the first place.

Can it be replaced without removing the control board?

A: The switch is soldered, so the control section has to be opened. It is a fine soldering job — if you are not set up for board work we can do it as part of a control section repair.

Will it fit other Olympus scopes?

A: The same style of switch is used across the 290 series, but the seat and lead length differ. Tell us the exact model and send a photo of the old switch before ordering.

Is it new or desoldered?

A: New and unused. A desoldered switch usually has shortened or bent leads and a heat-damaged body.

Do you repair the control section as well?

A: Yes. We repair Olympus flexible endoscopes at board level, including button and cover replacement, then leak test and return the scope.

► More service

Spare parts for flexible endoscopes could be provided including: control section buttons and switches, control knob, bending section, coil pipe, braided mesh, bending rubber, insertion tube, light bundle, CCD, nozzle, air/water tube and biopsy channel.

We also repair flexible gastroscopes, colonoscopes, bronchoscopes and cystoscopes, and run repair training courses for endoscope service.

For more information just contact us.

► About Us

CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.

Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.

► What we can do

CareUtech medical equipment repair and spare parts service

Product details

In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.

Product details

In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.

Description

1-Core Button Switch For Olympus GIF-HQ290 Gastroscope Control Section Repair Part

► Brief Description

The control section of the GIF-HQ290 carries a row of small push buttons under the rubber cover: image freeze, insufflation/aspiration selection and the programmable keys. Each one is a single-core micro switch with a short lead that is soldered to the control board and held in a moulded seat under the cover.

These switches fail in two ways. Mechanically, the plunger wears or the contact oxidises so the button needs a hard press, works intermittently, or stops responding altogether. And because the switch sits under the rubber cover, a split cover lets cleaning fluid and disinfectant reach the contacts, which corrodes them and can track along the lead into the control board.

We supply the replacement as a new, unused 1-core button switch with lead wire, as shown in the photos. If only one key has stopped working there is no need to replace the whole control board or the button strip assembly — this single switch is the part to change.

► Features

  • 1-core push button: single pole, normally open, with lead wire ready to solder to the control board.
  • For the GIF-HQ290 control section: fits the moulded seat under the button cover, same height as the original so the rubber cover sits flat.
  • New, unused: clean contacts, no solder residue or pulled leads.
  • Single-key repair: replace one failed button without buying the full button strip or the control board.
  • Photo matching: send a close-up of your old switch with the lead direction visible and we will confirm the type before shipping.
  • Repair support: we also service GIF-HQ290 control sections, including cover replacement and board-level repair.

1-core button switches for Olympus GIF-HQ290 gastroscope control section One core button switch with lead wire for Olympus GIF-HQ290 gastroscope Single core push button switch for Olympus endoscope control section Olympus GIF-HQ290 button switches in sealed package

► Specification

Product 1-core button switch with lead wire
Application OLYMPUS GIF-HQ290 gastroscope control section
Switch type Single pole push button, 1 core
Termination Solder, lead wire attached
Mounting Moulded seat under the control section button cover
Function Freeze / insufflation-aspiration selection / programmable key
Condition Brand new
Quantity 1 piece
MOQ 1 Piece
Package Anti-static bag / foam + export carton
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept negotiation

► FAQ

How many switches do I need?

A: One switch per key. If a single button has stopped responding, one piece is enough. If several keys are dead, check the lead and the control board first, because the fault may be at the board end.

Is the rubber button cover included?

A: No, this listing is the switch only. We can supply the cover separately, and if the cover is split that is usually why the switch corroded in the first place.

Can it be replaced without removing the control board?

A: The switch is soldered, so the control section has to be opened. It is a fine soldering job — if you are not set up for board work we can do it as part of a control section repair.

Will it fit other Olympus scopes?

A: The same style of switch is used across the 290 series, but the seat and lead length differ. Tell us the exact model and send a photo of the old switch before ordering.

Is it new or desoldered?

A: New and unused. A desoldered switch usually has shortened or bent leads and a heat-damaged body.

Do you repair the control section as well?

A: Yes. We repair Olympus flexible endoscopes at board level, including button and cover replacement, then leak test and return the scope.

► More service

Spare parts for flexible endoscopes could be provided including: control section buttons and switches, control knob, bending section, coil pipe, braided mesh, bending rubber, insertion tube, light bundle, CCD, nozzle, air/water tube and biopsy channel.

We also repair flexible gastroscopes, colonoscopes, bronchoscopes and cystoscopes, and run repair training courses for endoscope service.

For more information just contact us.

► About Us

CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.

Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.

► What we can do

CareUtech medical equipment repair and spare parts service

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “1-Core Button Switch For Olympus GIF-HQ290 Gastroscope Control Section Repair Part”

Your email address will not be published. Required fields are marked *

Fix Once Right, Save Replacement Costs

Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.

However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.

Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.

If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!