Key Switch / Button Bushing Tool For Olympus CF-H185 CF-H190 GIF-H185 GIF-H190
Apple Shopping Event
Hurry and get discounts up to 20% Read more
Key Switch / Button Bushing Tool For Olympus CF-H185 CF-H190 GIF-H185 GIF-H190
Two-piece stainless hand tool for pressing key switch / button bushings out of and back into the Olympus 185 / 190 series endoscope control section. Knurled stepped pilot plus flanged sleeve with three locating holes keeps the bushing square.
- For CF-H185I/L, CF-H190I/L, GIF-H185, GIF-H190 and related control bodies
- Prevents pry marks and an ovalised bushing bore
- Stainless, knurled grip, reusable workshop tool
- Tool only – buttons, bushings and seals sold separately
All new aftermarket parts come with a 1-Year warranty. Quality is the first thing we consider. Check out our Warranty Assistance for more details.
All expedited shipping so you can get your medical machine back in action, fast. Check out our Shipping Policy for more details.
We prioritize your satisfaction. If your order doesn't meet your expectations within 90 days, you may be eligible for a refund. See our Easy Return Policy for details.
Description
Key Switch / Button Bushing Tool For Olympus CF-H185 CF-H190 GIF-H185 GIF-H190
► Brief Description
The control section of an Olympus 185 / 190 series endoscope carries the suction, air/water and remote-switch buttons in press-fit bushings. When a bushing is cracked, loose or leaking, it has to be pressed straight out and a new one pressed straight back in. Prying it with a screwdriver marks the plastic control body, and an off-centre press will ovalise the bore – after which the new bushing never seals and the scope fails its leak test at the control section.
The two-piece stainless hand tool in the photos is made for that job. The knurled handle ends in a stepped pilot that centres on the bushing bore; the matching sleeve has a flanged shoulder and three locating holes so it can be lined up with the switch housing before any pressure is applied. Because the force goes through the tool and not through the control body, the bushing comes out square and the new one goes back without tilting.
It is sized for the control sections of the Olympus CF-H185I / CF-H185L / CF-H190I / CF-H190L colonoscopes and GIF-H185 / GIF-H190 gastroscopes, and is useful on the related 180 / 190 series control bodies that share the same button seat. The tool is a workshop item – it does not include the buttons, bushings or seals themselves.
Please note: this is an aftermarket workshop tool, not an Olympus service part with an official part number. Check the bushing diameter on your scope against the stepped pilot before use, and always support the control body from the inside when pressing.
► Features
- Two-piece set: knurled press handle with stepped pilot, plus flanged installer sleeve with three locating holes.
- Straight, centred press: keeps the bushing square so the bore is not ovalised and the new seal seats properly.
- Protects the control body: force is taken by the tool shoulder instead of the plastic housing, so no pry marks around the button seat.
- For the 185 / 190 series: CF-H185I/L, CF-H190I/L, GIF-H185, GIF-H190 and related control bodies sharing the same button seat.
- Solid stainless construction: knurled non-slip grip, cleanable and reusable for workshop use.
- Repair support: we also supply the buttons, bushings and seals, and can do the control section repair in house.

► Specification
| Product | Key switch / button bushing removal and installation tool |
| Application | Flexible endoscope control section button / switch bushing |
| Compatible models | Olympus CF-H185I, CF-H185L, CF-H190I, CF-H190L, GIF-H185, GIF-H190 |
| Related series | Olympus 180 / 190 series control bodies with the same button seat |
| Construction | Stainless steel, knurled grip, stepped pilot, flanged sleeve |
| Set contents | 1 press handle + 1 installer sleeve (2 pieces as pictured) |
| Not included | Buttons, bushings, seals, endoscope |
| Condition | Brand new aftermarket workshop tool |
| Installation | Support the control body internally when pressing; check bushing diameter first |
| Quantity | 1 set |
| MOQ | 1 Set |
| Package | Anti-static bag / foam + export carton |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept negotiation |
► FAQ
Which scopes does it fit?
A: It is sized for the Olympus CF-H185I / CF-H185L / CF-H190I / CF-H190L colonoscopes and the GIF-H185 / GIF-H190 gastroscopes. It also suits related 180 / 190 series control bodies that use the same button seat – send a photo of your control section if you are unsure.
What exactly does it do?
A: It presses the press-fit button / key switch bushing out of the control body and presses the replacement back in, keeping the part square so the bore is not ovalised and the new seal seats.
Why not just use pliers or a screwdriver?
A: Prying marks the plastic control body and an angled press ovalises the bore. The scope then often fails a leak test at the control section even after a new bushing is fitted.
Are the buttons or bushings included?
A: No. This listing is the two-piece tool only. Buttons, bushings and seals are separate parts – ask us and we will quote them together.
Is it an original Olympus tool?
A: No. It is a brand new aftermarket workshop tool and does not carry an Olympus part number. If you require the original service tool, ask us for a separate quotation.
Can you do the repair for me?
A: Yes. We repair flexible endoscope control sections, replace button bushings and seals, and leak test the scope before it is returned.
► More service
Spare parts for flexible endoscopes could be provided including: bending section, coil pipe, braided mesh, bending rubber, insertion tube, light bundle, light guide tube, CCD, CCD driver board, objective lens, distal head, nozzle, air/water tube, biopsy channel, angulation wire, control knob and buttons.
We also repair flexible gastroscopes, colonoscopes, bronchoscopes and cystoscopes, and run repair training courses for endoscope service.
For more information just contact us.
► About Us
CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.
Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.
► What we can do

Product details
In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.
Product details
In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.
Description
Key Switch / Button Bushing Tool For Olympus CF-H185 CF-H190 GIF-H185 GIF-H190
► Brief Description
The control section of an Olympus 185 / 190 series endoscope carries the suction, air/water and remote-switch buttons in press-fit bushings. When a bushing is cracked, loose or leaking, it has to be pressed straight out and a new one pressed straight back in. Prying it with a screwdriver marks the plastic control body, and an off-centre press will ovalise the bore – after which the new bushing never seals and the scope fails its leak test at the control section.
The two-piece stainless hand tool in the photos is made for that job. The knurled handle ends in a stepped pilot that centres on the bushing bore; the matching sleeve has a flanged shoulder and three locating holes so it can be lined up with the switch housing before any pressure is applied. Because the force goes through the tool and not through the control body, the bushing comes out square and the new one goes back without tilting.
It is sized for the control sections of the Olympus CF-H185I / CF-H185L / CF-H190I / CF-H190L colonoscopes and GIF-H185 / GIF-H190 gastroscopes, and is useful on the related 180 / 190 series control bodies that share the same button seat. The tool is a workshop item – it does not include the buttons, bushings or seals themselves.
Please note: this is an aftermarket workshop tool, not an Olympus service part with an official part number. Check the bushing diameter on your scope against the stepped pilot before use, and always support the control body from the inside when pressing.
► Features
- Two-piece set: knurled press handle with stepped pilot, plus flanged installer sleeve with three locating holes.
- Straight, centred press: keeps the bushing square so the bore is not ovalised and the new seal seats properly.
- Protects the control body: force is taken by the tool shoulder instead of the plastic housing, so no pry marks around the button seat.
- For the 185 / 190 series: CF-H185I/L, CF-H190I/L, GIF-H185, GIF-H190 and related control bodies sharing the same button seat.
- Solid stainless construction: knurled non-slip grip, cleanable and reusable for workshop use.
- Repair support: we also supply the buttons, bushings and seals, and can do the control section repair in house.

► Specification
| Product | Key switch / button bushing removal and installation tool |
| Application | Flexible endoscope control section button / switch bushing |
| Compatible models | Olympus CF-H185I, CF-H185L, CF-H190I, CF-H190L, GIF-H185, GIF-H190 |
| Related series | Olympus 180 / 190 series control bodies with the same button seat |
| Construction | Stainless steel, knurled grip, stepped pilot, flanged sleeve |
| Set contents | 1 press handle + 1 installer sleeve (2 pieces as pictured) |
| Not included | Buttons, bushings, seals, endoscope |
| Condition | Brand new aftermarket workshop tool |
| Installation | Support the control body internally when pressing; check bushing diameter first |
| Quantity | 1 set |
| MOQ | 1 Set |
| Package | Anti-static bag / foam + export carton |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept negotiation |
► FAQ
Which scopes does it fit?
A: It is sized for the Olympus CF-H185I / CF-H185L / CF-H190I / CF-H190L colonoscopes and the GIF-H185 / GIF-H190 gastroscopes. It also suits related 180 / 190 series control bodies that use the same button seat – send a photo of your control section if you are unsure.
What exactly does it do?
A: It presses the press-fit button / key switch bushing out of the control body and presses the replacement back in, keeping the part square so the bore is not ovalised and the new seal seats.
Why not just use pliers or a screwdriver?
A: Prying marks the plastic control body and an angled press ovalises the bore. The scope then often fails a leak test at the control section even after a new bushing is fitted.
Are the buttons or bushings included?
A: No. This listing is the two-piece tool only. Buttons, bushings and seals are separate parts – ask us and we will quote them together.
Is it an original Olympus tool?
A: No. It is a brand new aftermarket workshop tool and does not carry an Olympus part number. If you require the original service tool, ask us for a separate quotation.
Can you do the repair for me?
A: Yes. We repair flexible endoscope control sections, replace button bushings and seals, and leak test the scope before it is returned.
► More service
Spare parts for flexible endoscopes could be provided including: bending section, coil pipe, braided mesh, bending rubber, insertion tube, light bundle, light guide tube, CCD, CCD driver board, objective lens, distal head, nozzle, air/water tube, biopsy channel, angulation wire, control knob and buttons.
We also repair flexible gastroscopes, colonoscopes, bronchoscopes and cystoscopes, and run repair training courses for endoscope service.
For more information just contact us.
► About Us
CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.
Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.
► What we can do

Customer Reviews
Related Products
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!