CCD Driver Board For Pentax EC-3890Li Colonoscope / EG-2990i Gastroscope

Apple Shopping Event

Hurry and get discounts up to 20% Read more

CCD Driver Board For Pentax EC-3890Li Colonoscope / EG-2990i Gastroscope

► Brief Description

This is the CCD driver board that sits in the control section of the Pentax EC-3890Li colonoscope and the EG-2990i gastroscope. It carries the CCD clock and bias circuits, the video output stage and the two flat cable headers that connect to the image sensor harness and the umbilical cable.

When a scope shows a dead or intermittent image but the CCD itself and the umbilical cable test good, the driver board is the next suspect — a failed regulator or a cracked solder joint on the header will kill the video while everything else looks fine. Replacing the board is also the standard fix after liquid ingress into the control section, where corrosion on the board is easier to spot than to repair track by track.

Every board is checked on a bench scope before it is packed: image present, no rolling, no lines, connectors seated. Boards are shipped in antistatic bags, and we can match the board to your scope if you send a photo of the faulty one.

► Features

  • Direct replacement: same footprint, same connector layout as the original Pentax board — no rewiring or adapter harness.
  • Bench tested: each board is run on a scope before shipping, so you receive a board that is known to produce a stable image, not just a board that powers up.
  • Shared platform: the same green PCB is used across the EC-3890Li / EG-2990i generation, which keeps one spare on the shelf instead of two.
  • Antistatic packed: shipped in a sealed antistatic bag inside foam, protected against ESD damage in transit.
  • Photo matching: send us a picture of the faulty board and we will confirm the revision before you order.
  • Repair support: if you would rather repair than replace, we can advise on the common failure points of this board.

► Specification

Product CCD driver board (video processor PCB)
Application Pentax EC-3890Li colonoscope / EG-2990i gastroscope
Board marking 5AV-0, green PCB
Connectors 2 x flat cable headers, camera cable connector, test points
Function Drives the CCD, transmits the video signal to the processor
Condition Original used, tested
Quantity 1 piece
MOQ 1 Piece
Package Anti-static bag / foam + export carton
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept negotiation

Warranty Policy

All new aftermarket parts come with a 1-Year warranty. Quality is the first thing we consider. Check out our Warranty Assistance for more details.

Shipping Policy

All expedited shipping so you can get your medical machine back in action, fast. Check out our Shipping Policy for more details.

Easy Return Policy

We prioritize your satisfaction. If your order doesn't meet your expectations within 90 days, you may be eligible for a refund. See our Easy Return Policy for details.

Description

CCD Driver Board For Pentax EC-3890Li Colonoscope / EG-2990i Gastroscope

► Brief Description

This is the CCD driver board that sits in the control section of the Pentax EC-3890Li colonoscope and the EG-2990i gastroscope. It carries the CCD clock and bias circuits, the video output stage and the two flat cable headers that connect to the image sensor harness and the umbilical cable.

When a scope shows a dead or intermittent image but the CCD itself and the umbilical cable test good, the driver board is the next suspect — a failed regulator or a cracked solder joint on the header will kill the video while everything else looks fine. Replacing the board is also the standard fix after liquid ingress into the control section, where corrosion on the board is easier to spot than to repair track by track.

Every board is checked on a bench scope before it is packed: image present, no rolling, no lines, connectors seated. Boards are shipped in antistatic bags, and we can match the board to your scope if you send a photo of the faulty one.

► Features

  • Direct replacement: same footprint, same connector layout as the original Pentax board — no rewiring or adapter harness.
  • Bench tested: each board is run on a scope before shipping, so you receive a board that is known to produce a stable image, not just a board that powers up.
  • Shared platform: the same green PCB is used across the EC-3890Li / EG-2990i generation, which keeps one spare on the shelf instead of two.
  • Antistatic packed: shipped in a sealed antistatic bag inside foam, protected against ESD damage in transit.
  • Photo matching: send us a picture of the faulty board and we will confirm the revision before you order.
  • Repair support: if you would rather repair than replace, we can advise on the common failure points of this board.

CCD driver board for Pentax EC-3890Li colonoscope green PCB top view CCD driver board for Pentax EG-2990i gastroscope green PCB Pentax endoscope CCD driver board in antistatic bag showing connectors Green CCD driver board spare part for Pentax video colonoscope PCB detail of the CCD driver board for Pentax endoscope repair

► Specification

Product CCD driver board (video processor PCB)
Application Pentax EC-3890Li colonoscope / EG-2990i gastroscope
Board marking 5AV-0, green PCB
Connectors 2 x flat cable headers, camera cable connector, test points
Function Drives the CCD, transmits the video signal to the processor
Condition Original used, tested
Quantity 1 piece
MOQ 1 Piece
Package Anti-static bag / foam + export carton
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept negotiation

► FAQ

How do I know the driver board is the fault and not the CCD?

A: If the image is completely dead or drops out intermittently while the light guide and lens are fine, and the umbilical cable passes a continuity test, the board is the usual cause. A CCD failure more often shows as a colour cast, dead pixels or a fixed pattern. Send us the symptoms and a photo and we will help you narrow it down.

Is this board new or used?

A: It is an original board in used condition, tested on a bench scope. If you need a brand new board, tell us — availability varies by revision.

Will it fit the EC-38i10 as well?

A: The EC-38i10 uses a different board. We supply that one separately — send the model and we will quote the correct part.

Do you supply the CCD and the cables too?

A: Yes. CCD modules, light guide bundles, insertion tubes and bending sections for this generation are also available.

► More service

Spare parts for flexible endoscope could be provided including: insertion tube, bending section, bending rubber, coil pipe, angle wire, light guide bundle, light guide lens, CCD objective lens, CCD driver board, air water tube, biopsy channel, suction valve, air water valve and video cable.

For more information just contact us.

► About Us

CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.

Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.

► What we can do

CareUtech medical equipment repair and spare parts service

Product details

In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.

Product details

In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.

Description

CCD Driver Board For Pentax EC-3890Li Colonoscope / EG-2990i Gastroscope

► Brief Description

This is the CCD driver board that sits in the control section of the Pentax EC-3890Li colonoscope and the EG-2990i gastroscope. It carries the CCD clock and bias circuits, the video output stage and the two flat cable headers that connect to the image sensor harness and the umbilical cable.

When a scope shows a dead or intermittent image but the CCD itself and the umbilical cable test good, the driver board is the next suspect — a failed regulator or a cracked solder joint on the header will kill the video while everything else looks fine. Replacing the board is also the standard fix after liquid ingress into the control section, where corrosion on the board is easier to spot than to repair track by track.

Every board is checked on a bench scope before it is packed: image present, no rolling, no lines, connectors seated. Boards are shipped in antistatic bags, and we can match the board to your scope if you send a photo of the faulty one.

► Features

  • Direct replacement: same footprint, same connector layout as the original Pentax board — no rewiring or adapter harness.
  • Bench tested: each board is run on a scope before shipping, so you receive a board that is known to produce a stable image, not just a board that powers up.
  • Shared platform: the same green PCB is used across the EC-3890Li / EG-2990i generation, which keeps one spare on the shelf instead of two.
  • Antistatic packed: shipped in a sealed antistatic bag inside foam, protected against ESD damage in transit.
  • Photo matching: send us a picture of the faulty board and we will confirm the revision before you order.
  • Repair support: if you would rather repair than replace, we can advise on the common failure points of this board.

CCD driver board for Pentax EC-3890Li colonoscope green PCB top view CCD driver board for Pentax EG-2990i gastroscope green PCB Pentax endoscope CCD driver board in antistatic bag showing connectors Green CCD driver board spare part for Pentax video colonoscope PCB detail of the CCD driver board for Pentax endoscope repair

► Specification

Product CCD driver board (video processor PCB)
Application Pentax EC-3890Li colonoscope / EG-2990i gastroscope
Board marking 5AV-0, green PCB
Connectors 2 x flat cable headers, camera cable connector, test points
Function Drives the CCD, transmits the video signal to the processor
Condition Original used, tested
Quantity 1 piece
MOQ 1 Piece
Package Anti-static bag / foam + export carton
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept negotiation

► FAQ

How do I know the driver board is the fault and not the CCD?

A: If the image is completely dead or drops out intermittently while the light guide and lens are fine, and the umbilical cable passes a continuity test, the board is the usual cause. A CCD failure more often shows as a colour cast, dead pixels or a fixed pattern. Send us the symptoms and a photo and we will help you narrow it down.

Is this board new or used?

A: It is an original board in used condition, tested on a bench scope. If you need a brand new board, tell us — availability varies by revision.

Will it fit the EC-38i10 as well?

A: The EC-38i10 uses a different board. We supply that one separately — send the model and we will quote the correct part.

Do you supply the CCD and the cables too?

A: Yes. CCD modules, light guide bundles, insertion tubes and bending sections for this generation are also available.

► More service

Spare parts for flexible endoscope could be provided including: insertion tube, bending section, bending rubber, coil pipe, angle wire, light guide bundle, light guide lens, CCD objective lens, CCD driver board, air water tube, biopsy channel, suction valve, air water valve and video cable.

For more information just contact us.

► About Us

CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.

Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.

► What we can do

CareUtech medical equipment repair and spare parts service

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “CCD Driver Board For Pentax EC-3890Li Colonoscope / EG-2990i Gastroscope”

Your email address will not be published. Required fields are marked *

Fix Once Right, Save Replacement Costs

Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.

However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.

Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.

If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!