CCD Driver Board For Pentax EC-3890Li Colonoscope / EG-2990i Gastroscope
► Brief Description
This is the CCD driver board that sits in the control section of the Pentax EC-3890Li colonoscope and the EG-2990i gastroscope. It carries the CCD clock and bias circuits, the video output stage and the two flat cable headers that connect to the image sensor harness and the umbilical cable.
When a scope shows a dead or intermittent image but the CCD itself and the umbilical cable test good, the driver board is the next suspect — a failed regulator or a cracked solder joint on the header will kill the video while everything else looks fine. Replacing the board is also the standard fix after liquid ingress into the control section, where corrosion on the board is easier to spot than to repair track by track.
Every board is checked on a bench scope before it is packed: image present, no rolling, no lines, connectors seated. Boards are shipped in antistatic bags, and we can match the board to your scope if you send a photo of the faulty one.
► Features
- Direct replacement: same footprint, same connector layout as the original Pentax board — no rewiring or adapter harness.
- Bench tested: each board is run on a scope before shipping, so you receive a board that is known to produce a stable image, not just a board that powers up.
- Shared platform: the same green PCB is used across the EC-3890Li / EG-2990i generation, which keeps one spare on the shelf instead of two.
- Antistatic packed: shipped in a sealed antistatic bag inside foam, protected against ESD damage in transit.
- Photo matching: send us a picture of the faulty board and we will confirm the revision before you order.
- Repair support: if you would rather repair than replace, we can advise on the common failure points of this board.
► Specification
| Product | CCD driver board (video processor PCB) |
| Application | Pentax EC-3890Li colonoscope / EG-2990i gastroscope |
| Board marking | 5AV-0, green PCB |
| Connectors | 2 x flat cable headers, camera cable connector, test points |
| Function | Drives the CCD, transmits the video signal to the processor |
| Condition | Original used, tested |
| Quantity | 1 piece |
| MOQ | 1 Piece |
| Package | Anti-static bag / foam + export carton |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept negotiation |
All new aftermarket parts come with a 1-Year warranty. Quality is the first thing we consider. Check out our Warranty Assistance for more details.
All expedited shipping so you can get your medical machine back in action, fast. Check out our Shipping Policy for more details.
We prioritize your satisfaction. If your order doesn't meet your expectations within 90 days, you may be eligible for a refund. See our Easy Return Policy for details.
Description
CCD Driver Board For Pentax EC-3890Li Colonoscope / EG-2990i Gastroscope
► Brief Description
This is the CCD driver board that sits in the control section of the Pentax EC-3890Li colonoscope and the EG-2990i gastroscope. It carries the CCD clock and bias circuits, the video output stage and the two flat cable headers that connect to the image sensor harness and the umbilical cable.
When a scope shows a dead or intermittent image but the CCD itself and the umbilical cable test good, the driver board is the next suspect — a failed regulator or a cracked solder joint on the header will kill the video while everything else looks fine. Replacing the board is also the standard fix after liquid ingress into the control section, where corrosion on the board is easier to spot than to repair track by track.
Every board is checked on a bench scope before it is packed: image present, no rolling, no lines, connectors seated. Boards are shipped in antistatic bags, and we can match the board to your scope if you send a photo of the faulty one.
► Features
- Direct replacement: same footprint, same connector layout as the original Pentax board — no rewiring or adapter harness.
- Bench tested: each board is run on a scope before shipping, so you receive a board that is known to produce a stable image, not just a board that powers up.
- Shared platform: the same green PCB is used across the EC-3890Li / EG-2990i generation, which keeps one spare on the shelf instead of two.
- Antistatic packed: shipped in a sealed antistatic bag inside foam, protected against ESD damage in transit.
- Photo matching: send us a picture of the faulty board and we will confirm the revision before you order.
- Repair support: if you would rather repair than replace, we can advise on the common failure points of this board.

► Specification
| Product | CCD driver board (video processor PCB) |
| Application | Pentax EC-3890Li colonoscope / EG-2990i gastroscope |
| Board marking | 5AV-0, green PCB |
| Connectors | 2 x flat cable headers, camera cable connector, test points |
| Function | Drives the CCD, transmits the video signal to the processor |
| Condition | Original used, tested |
| Quantity | 1 piece |
| MOQ | 1 Piece |
| Package | Anti-static bag / foam + export carton |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept negotiation |
► FAQ
How do I know the driver board is the fault and not the CCD?
A: If the image is completely dead or drops out intermittently while the light guide and lens are fine, and the umbilical cable passes a continuity test, the board is the usual cause. A CCD failure more often shows as a colour cast, dead pixels or a fixed pattern. Send us the symptoms and a photo and we will help you narrow it down.
Is this board new or used?
A: It is an original board in used condition, tested on a bench scope. If you need a brand new board, tell us — availability varies by revision.
Will it fit the EC-38i10 as well?
A: The EC-38i10 uses a different board. We supply that one separately — send the model and we will quote the correct part.
Do you supply the CCD and the cables too?
A: Yes. CCD modules, light guide bundles, insertion tubes and bending sections for this generation are also available.
► More service
Spare parts for flexible endoscope could be provided including: insertion tube, bending section, bending rubber, coil pipe, angle wire, light guide bundle, light guide lens, CCD objective lens, CCD driver board, air water tube, biopsy channel, suction valve, air water valve and video cable.
For more information just contact us.
► About Us
CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.
Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.
► What we can do

Product details
In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.
Product details
In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.
Description
CCD Driver Board For Pentax EC-3890Li Colonoscope / EG-2990i Gastroscope
► Brief Description
This is the CCD driver board that sits in the control section of the Pentax EC-3890Li colonoscope and the EG-2990i gastroscope. It carries the CCD clock and bias circuits, the video output stage and the two flat cable headers that connect to the image sensor harness and the umbilical cable.
When a scope shows a dead or intermittent image but the CCD itself and the umbilical cable test good, the driver board is the next suspect — a failed regulator or a cracked solder joint on the header will kill the video while everything else looks fine. Replacing the board is also the standard fix after liquid ingress into the control section, where corrosion on the board is easier to spot than to repair track by track.
Every board is checked on a bench scope before it is packed: image present, no rolling, no lines, connectors seated. Boards are shipped in antistatic bags, and we can match the board to your scope if you send a photo of the faulty one.
► Features
- Direct replacement: same footprint, same connector layout as the original Pentax board — no rewiring or adapter harness.
- Bench tested: each board is run on a scope before shipping, so you receive a board that is known to produce a stable image, not just a board that powers up.
- Shared platform: the same green PCB is used across the EC-3890Li / EG-2990i generation, which keeps one spare on the shelf instead of two.
- Antistatic packed: shipped in a sealed antistatic bag inside foam, protected against ESD damage in transit.
- Photo matching: send us a picture of the faulty board and we will confirm the revision before you order.
- Repair support: if you would rather repair than replace, we can advise on the common failure points of this board.

► Specification
| Product | CCD driver board (video processor PCB) |
| Application | Pentax EC-3890Li colonoscope / EG-2990i gastroscope |
| Board marking | 5AV-0, green PCB |
| Connectors | 2 x flat cable headers, camera cable connector, test points |
| Function | Drives the CCD, transmits the video signal to the processor |
| Condition | Original used, tested |
| Quantity | 1 piece |
| MOQ | 1 Piece |
| Package | Anti-static bag / foam + export carton |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept negotiation |
► FAQ
How do I know the driver board is the fault and not the CCD?
A: If the image is completely dead or drops out intermittently while the light guide and lens are fine, and the umbilical cable passes a continuity test, the board is the usual cause. A CCD failure more often shows as a colour cast, dead pixels or a fixed pattern. Send us the symptoms and a photo and we will help you narrow it down.
Is this board new or used?
A: It is an original board in used condition, tested on a bench scope. If you need a brand new board, tell us — availability varies by revision.
Will it fit the EC-38i10 as well?
A: The EC-38i10 uses a different board. We supply that one separately — send the model and we will quote the correct part.
Do you supply the CCD and the cables too?
A: Yes. CCD modules, light guide bundles, insertion tubes and bending sections for this generation are also available.
► More service
Spare parts for flexible endoscope could be provided including: insertion tube, bending section, bending rubber, coil pipe, angle wire, light guide bundle, light guide lens, CCD objective lens, CCD driver board, air water tube, biopsy channel, suction valve, air water valve and video cable.
For more information just contact us.
► About Us
CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.
Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.
► What we can do

Customer Reviews
Related Products
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!

Reviews
Clear filtersThere are no reviews yet.