High Quality Variable Stiffness Coil Assembly For Olympus CF-H190L Colonoscope

Apple Shopping Event

Hurry and get discounts up to 20% Read more

Brief Description

The Variable Stiffness Wire/Coil is a core mechanical element of Olympus’s proprietary RIT (Responsive Insertion Technology) found in the CF-H190L colonoscope.

Unlike gastroscopes, colonoscopes navigate acute loops in the large intestine. This internal steel wire and coil assembly allows the endoscopist to adjust the rigidity of the insertion tube in real-time, helping to prevent loop formation and minimize patient discomfort.

►Features

  • Variable Stiffness Adjustment:When the physician turns the adjustment ring on the endoscope’s control section, it pulls or releases the internal stiffness wire. Tensioning the wire compresses the surrounding outer coil, causing the insertion tube to shift from highly flexible to rigid.
  • Loop Prevention:During colonoscopy advancement (especially through the sigmoid colon), increasing the stiffness helps transfer the pushing force directly to the distal tip, preventing the endoscope from looping or bowing inside the patient.
  • High Force Transmission (HFT):Working in tandem with the wire tension, it ensures that twisting or torque applied by the physician’s hand is accurately translated down the insertion tube.

►Specification

Brand Olympus
Model CF-H190L
Condition Working in good condition
Series Variable Stiffness Coil Assembly
Material High-grade Medical Stainless Steel
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Warranty Policy

All new aftermarket parts come with a 1-Year warranty. Quality is the first thing we consider. Check out our Warranty Assistance for more details.

Shipping Policy

All expedited shipping so you can get your medical machine back in action, fast. Check out our Shipping Policy for more details.

Easy Return Policy

We prioritize your satisfaction. If your order doesn't meet your expectations within 90 days, you may be eligible for a refund. See our Easy Return Policy for details.

Description

Variable Stiffness Coil Assembly For Olympus CF-H190L Colonoscope

6d128604d7865f2bcdb6b500448dc317 ae6dc467d3137633dd5528eb737837af f4b9d53816c95668beb25266da7bb1ff 1 02123889e0f871ad32491570befd9e47

Brief Description

The Variable Stiffness Wire/Coil is a core mechanical element of Olympus’s proprietary RIT (Responsive Insertion Technology) found in the CF-H190L colonoscope.

Unlike gastroscopes, colonoscopes navigate acute loops in the large intestine. This internal steel wire and coil assembly allows the endoscopist to adjust the rigidity of the insertion tube in real-time, helping to prevent loop formation and minimize patient discomfort.

►Features

  • Variable Stiffness Adjustment:When the physician turns the adjustment ring on the endoscope’s control section, it pulls or releases the internal stiffness wire. Tensioning the wire compresses the surrounding outer coil, causing the insertion tube to shift from highly flexible to rigid.
  • Loop Prevention:During colonoscopy advancement (especially through the sigmoid colon), increasing the stiffness helps transfer the pushing force directly to the distal tip, preventing the endoscope from looping or bowing inside the patient.
  • High Force Transmission (HFT):Working in tandem with the wire tension, it ensures that twisting or torque applied by the physician’s hand is accurately translated down the insertion tube.

►Specification

Brand Olympus
Model CF-H190L
Condition Working in good condition
Series Variable Stiffness Coil Assembly
Material High-grade Medical Stainless Steel
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

►FAQ

What are the primary clinical signs that the stiffness wire has broken?

A: If the internal steel wire breaks or snaps, you will typically notice:

  • No change in rigidity: Turning the adjustment ring from 0 to 3 yields absolutely no change in the flexibility of the endoscope.

  • Loss of tactile resistance: The adjustment ring on the control head may feel completely loose or turn with zero resistance.

  • Sudden looping: The endoscope loops much more easily in the sigmoid colon than usual, despite dial adjustments.

Why does the adjustment ring feel stuck or very stiff to turn?

A:This is usually caused by a kinked stiffness wire or corrosion inside the endoscope. If the endoscope suffers a minor fluid invasion that goes unnoticed, the internal stainless steel components can rust and bind together. Alternatively, if the insertion tube was severely bent or crushed during a procedure or reprocessing, the wire inside may have kinked, preventing it from sliding smoothly through the outer coil.

► More service

Spare parts for flexible endoscope: insert tube, wires,helix tube,coil pipe,C-cover,glass for CCD,glass for light bundle,objective lens for CCD,drive board for CCD,light guide tube, light bundle,forcep tube, bending section, rubber, air&water tube, CCD, light source, processor, monitor, etc.

► About Us

CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.

Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.

 

►What we can do 

e103f202af370e20fed443c4c46ca11

Product details

In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.

Product details

In case you have any questions or concerns, don’t be shy to get in touch with our support team. Our experts will help you select the right type of endoscope accessories, providing you with the best advice possible.

Description

Variable Stiffness Coil Assembly For Olympus CF-H190L Colonoscope

6d128604d7865f2bcdb6b500448dc317 ae6dc467d3137633dd5528eb737837af f4b9d53816c95668beb25266da7bb1ff 1 02123889e0f871ad32491570befd9e47

Brief Description

The Variable Stiffness Wire/Coil is a core mechanical element of Olympus’s proprietary RIT (Responsive Insertion Technology) found in the CF-H190L colonoscope.

Unlike gastroscopes, colonoscopes navigate acute loops in the large intestine. This internal steel wire and coil assembly allows the endoscopist to adjust the rigidity of the insertion tube in real-time, helping to prevent loop formation and minimize patient discomfort.

►Features

  • Variable Stiffness Adjustment:When the physician turns the adjustment ring on the endoscope’s control section, it pulls or releases the internal stiffness wire. Tensioning the wire compresses the surrounding outer coil, causing the insertion tube to shift from highly flexible to rigid.
  • Loop Prevention:During colonoscopy advancement (especially through the sigmoid colon), increasing the stiffness helps transfer the pushing force directly to the distal tip, preventing the endoscope from looping or bowing inside the patient.
  • High Force Transmission (HFT):Working in tandem with the wire tension, it ensures that twisting or torque applied by the physician’s hand is accurately translated down the insertion tube.

►Specification

Brand Olympus
Model CF-H190L
Condition Working in good condition
Series Variable Stiffness Coil Assembly
Material High-grade Medical Stainless Steel
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

►FAQ

What are the primary clinical signs that the stiffness wire has broken?

A: If the internal steel wire breaks or snaps, you will typically notice:

  • No change in rigidity: Turning the adjustment ring from 0 to 3 yields absolutely no change in the flexibility of the endoscope.

  • Loss of tactile resistance: The adjustment ring on the control head may feel completely loose or turn with zero resistance.

  • Sudden looping: The endoscope loops much more easily in the sigmoid colon than usual, despite dial adjustments.

Why does the adjustment ring feel stuck or very stiff to turn?

A:This is usually caused by a kinked stiffness wire or corrosion inside the endoscope. If the endoscope suffers a minor fluid invasion that goes unnoticed, the internal stainless steel components can rust and bind together. Alternatively, if the insertion tube was severely bent or crushed during a procedure or reprocessing, the wire inside may have kinked, preventing it from sliding smoothly through the outer coil.

► More service

Spare parts for flexible endoscope: insert tube, wires,helix tube,coil pipe,C-cover,glass for CCD,glass for light bundle,objective lens for CCD,drive board for CCD,light guide tube, light bundle,forcep tube, bending section, rubber, air&water tube, CCD, light source, processor, monitor, etc.

► About Us

CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.

Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.

 

►What we can do 

e103f202af370e20fed443c4c46ca11

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “High Quality Variable Stiffness Coil Assembly For Olympus CF-H190L Colonoscope”

Your email address will not be published. Required fields are marked *

Fix Once Right, Save Replacement Costs

Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.

However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.

Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.

If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!