SHOP
Product Categories
- NEW PRODUCT 6
- Parts for Anesthesia 0
- Parts for Camera system 86
- Parts for Defibrillator 0
- Parts for Dynamical System 86
- Parts for Flexible Endoscope 327
- Parts for Microplate Reader 1
- Parts for Monitor 7
- Parts for MRI 0
- Parts for Rigid Endoscope 11
- Parts for Surgical Instrument 47
- Parts for Ultrasound & Probe 88
- Parts for Ventilator 91
- PCR and Centrifuge 8
- Repair Cases 172
- Repair Tools 23
- Repair Training Course 7
Filter by brand
Filter by price
Featured Products
-
Medical Equipment Repair Certification Course Of Olympus 260 Series Flexible Endoscope Repair Training Course For Kazakhstani Clients
-
Advanced Medical Equipment Repair Certification Repair Training Course Of Rigidscope Training For Italy Client
-
Advanced Medical Equipment Repair Certification Course Of Olympus 290 Colonoscopy and Bronchoscopy For South Korean Client
-
Advanced Medical Equipment Repair Certification Repair Training Course Of Camera Head Training For Italy Clients
Showing 289–304 of 960 results
Fuji Air Water Bottle 260/180 Series Endoscope
Fuji Air Water Bottle 260/180 Series Endoscope for sale, Buy brand new Flexible Endoscope for FUJI.Order now!
FUJINON EG-530N endoscope for repair. SN: 5G250****
FUJINON EG-530N endoscope for repair. SN: 5G250**** for sale, Buy brand new flexible endoscope repair parts for FUJI.Order now!
FUJINON EG-250WR5 ENDOSCOPE LIGHT GUIDE TUBE
FUJINON EG-250WR5 ENDOSCOPE LIGHT GUIDE TUBE for sale, Buy brand new Flexible Endoscope for FUJINON.Order now!
FUJINON EG-530N gastroscope for repair
$0.00► Brief Description
Fault:
1.Biopsy tube broken;
2.Angle is not enough;
3.Camera over-heating, there are occasional snowflakes on the image and big risk for CCD;
4.Insert tube aging and wrinkle;
5.Light guide tube aging and wrinkleï¼›
6.Stress boot of light guide tube broken;
7.Light bundle broken;
8.EVE tube aging and wrinkle.
Solution:
1: Replace CCD; insert tube; light bundle; biopsy tube; bending mesh; wires; bending section; rubber; light guide tube; stress boot; eve tube
2: Replace insert tube, light bundle, biopsy tube, bending mesh and wired, coil pipe, rubber, light guide tube, stress tube, eve tube
3: Replace insert tube, light bundle, biopsy tube, bending mesh and wires, bending section, rubber
â–ºProblem & Solutoin
| Brand | FUJINON |
| Model | EG-530N |
| Fault | 1.Biopsy tube broken; 2.Angle is not enough; 3.Camera over-heating, there are occasional snowflakes on the image and big risk for CCD; 4.Insert tube aging and wrinkle; 5.Light guide tube aging and wrinkleï¼› 6.Stress boot of light guide tube broken; 7.Light bundle broken; 8.EVE tube aging and wrinkle. |
| Solution | 1: Replace CCD; insert tube; light bundle; biopsy tube; bending mesh; wires; bending section; rubber; light guide tube; stress boot; eve tube Solution 2: Replace insert tube, light bundle, biopsy tube, bending mesh and wired, coil pipe, rubber, light guide tube, stress tube, eve tube Solution 3: Replace insert tube, light bundle, biopsy tube, bending mesh and wires, bending section, rubber |
► Common issues with EG-530N gastroscope
- Poor Image Quality
- Insertion Tube Issues
- Suction/Air/Water Issues
- Instrument Channel Problems
- Damaged Control Body
- Loose Angulation Knobs
- Light Guide Fiber Breakage
FUJINON EG-590WR ENDOSCOPE LIGHT GUIDE TUBE PROXIMAL END FITTING
FUJINON EG-590WR ENDOSCOPE LIGHT GUIDE TUBE PROXIMAL END FITTING for sale, Buy brand new Flexible Endoscope for FUJINON.Order now!
FUJINON EG-590WR LIGHT GUIDE TUBE
FUJINON EG-590WR LIGHT GUIDE TUBE for sale, Buy brand new Flexible Endoscope for Fujinon.Order now!
Fujinon Hand Held Leak Tester
Fujinon Hand Held Leak Tester for sale, Buy brand new Flexible Endoscope for Fujinon.Order now!
FUJINON WT-4 WATER BOTTLE
FUJINON WT-4 WATER BOTTLE for sale, Buy brand new Flexible Endoscope for FUJINON.Order now!
Gas Module Interface Board Maquet PC1770B For Servo-i Ventilator
$0.00â–º Brief Description
The PC1770B is a critical electronic component classified as a Gas Module Interface Board or Control PCB. It acts as the hardware bridge between the ventilator’s central processing unit and the pneumatic gas mixing system.
â–ºFeatures
- Signal Processing & Data Acquisition
- Actuator & Valve Control
- Communication & Synchronization
â–º Specification
| Brand | Maquet |
| Model | PC1770B |
| Condition | Brand new |
| Series | Gas Module Interface Board |
| Interface Type | Multi-pin Header |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Gastroscope of Olympus GIF-Q240X SN: 220**** for repair
Gastroscope of Olympus GIF-Q240X SN: 220**** for repair for sale, Buy brand new flexible endoscope repair parts for Olympus.Order now!
Gastroscope of Olympus GIF-XQ240 SN: 270**** for repair
Gastroscope of Olympus GIF-XQ240 SN: 270**** for repair for sale, Buy brand new flexible endoscope repair parts for Olympus.Order now!
GE 2021406-001 Nellcor OxiMax SpO2 Interconnect Cable For Patient Monitor
$0.00â–º Brief Description
The GE 2021406-001 is a high-performance SpO2 Interconnect Cable (also known as an extension or adapter cable) designed to bridge the connection between a GE Healthcare patient monitor and a Nellcor OxiMaxâ„¢ pulse oximetry sensor.
â–º Features
- Signal Conversion
- High Shielding
- Clinical Durability
- Plug-and-Play
- Gold-Plated Pins
â–º Specification
| Brand | GE |
| Model | 2021406-001 |
| Series | SpO2 Interconnect Cable |
| Condition | Original & new |
| Cable Type | SpO2 Adapter |
| Technology | Nellcor OxiMaxâ„¢ |
| Cable Length | 3.0 meters (10 feet) |
| MOQ | 1 Piece |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportatio | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
GE 3S-RS Cardiac probe for repair
GE 3S-RS Cardiac probe for repair for sale, Buy brand new flexible endoscope repair parts for GE.Order now!
GE 4C-RS abdominal probe for repair
GE 4C-RS abdominal probe for repair for sale, Buy brand new flexible endoscope repair parts for GE.Order now!
GE 4C-RS abdominal probe for repair
► Brief Description
Fault:Â Lens broken, cable broken, crystal bad.
Solution:Â Replace probe head, repair cable.
â–ºProblem & Solutoin
| Bran | GE |
| Model | 4C-RS |
| Fault | Lens broken, cable broken, crystal bad |
| Solution | Replace probe head, repair cable |
► Common issues with 4C-RS Probe
- Image dropouts / Black lines
- Acoustic lens damage
- Cable damage
- Connector damage
- Oil leakage
GE 4D3C-L 4D Convex Transducer For Repair
$0.00► Brief Description
Fault:Â 1.Probe dome abrasion & leakage,
       2. Dome tube damaged,
       3. 4D function not work,
       4. Electric motor damaged.
Solution:Replace the dome, dome tube; repair electric motor.
â–ºProblem & Solutoin
| Brand | GE |
| Model | 4D3C-L |
| Fault | 1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged. |
| Solution | Replace the dome, dome tube; repair electric motor |
► Common issues with 4D3C-L 4D Convex Transducer
- Image artifacts
- Failed array
- Damaged acoustic lens
- Intermittent signal or no image
- Loss of 4D function
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!