SHOP

OLYMPUS CCD DRIVER BOARD FOR CF-HQ190L COLONOVIDEOSCOPE

OLYMPUS CCD DRIVER BOARD FOR CF-HQ190L COLONOVIDEOSCOPE for sale, Buy brand new Flexible Endoscope for Olympus.Order now!

Olympus CCD for BF-260 Bronchoscope

Olympus CCD for BF-260 Bronchoscope for sale, Buy brand new Flexible Endoscope for OLYMPUS.Order now!

Olympus CCD For CF-H260AI Colonoscope

$0.00

► Brief Description

The Olympus CF-H260AI is a high-definition (HDTV) colonoscope from the EVIS EXERA II series. The CCD (Charge-Coupled Device) is the “eye” of the endoscope, located at the distal tip. It is responsible for converting light into electrical signals to produce the video image.

► Features

  • HDTV Image Capture
  • Narrow Band Imaging (NBI) Support
  • Light-to-Signal Conversion
  • Color Reproduction and Signal Processing

► Specification

Brand Olympus
Model CF-H260AI
Condition Working in Good Condition
Series CCD
Sensor Type High-Definition HDTV CCD
Image Resolution HDTV
Field of View (FOV) 140° (Wide-angle)
Depth of Field 3 mm to 100 mm
Aspect Ratio 4:3 or 16:9
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Olympus CCD for GIF-H260 Gastroscope

Olympus CCD for GIF-H260 Gastroscope for sale, Buy brand new Flexible Endoscope for OLYMPUS.Order now!

Olympus CCD For GIF-Q260 Gastroscope

Olympus CCD For GIF-Q260 Gastroscope for sale, Buy brand new Flexible Endoscope for OLYMPUS.Order now!

Olympus CCD For GIF-XQ260 Gastroscope

Olympus CCD For GIF-XQ260 Gastroscope for sale, Buy brand new Flexible Endoscope for OLYMPUS.Order now!

Olympus CCD for GIF-XQ260 Gastroscope

Olympus CCD for GIF-XQ260 Gastroscope for sale, Buy brand new Flexible Endoscope for OLYMPUS.Order now!

Olympus CF-240AI Colonoscope for repair

$0.00

► Brief Description

Fault: 

Image blur,insert tube aging,light guide squashed,light guide broken 50%,nozzle blocked,angle tight,forceps channel aging.

Solution:

Replace insertion tube,CCD chips,light guide,forceps channel,water channel,angulation wire,bending mesh,spiral tube,light guide tube,bending rubber.

â–ºProblem & Solutoin

Brand Olympus
Model CF-240AI
Fault Image blur,insert tube aging,light guide squashed,light guide broken 50%,nozzle blocked,angle tight,forceps channel aging.
Solution Replace insertion tube,CCD chips,light guide,forceps channel,water channel,angulation wire,bending mesh,spiral tube,light guide tube,bending rubber.

► Common issues with CF-240AI Colonoscope

  • Insertion Tube Damage
  • Image Quality Issues
  • Mechanism Failures
  • Connector and Light Source Issues

Olympus CF-240AI Colonoscope for repair

Olympus CF-240AI Colonoscope for repair for sale, Buy brand new flexible endoscope repair parts for Olympus.Order now!

Olympus CF-240AI Colonoscope for repair new

Olympus CF-240AI Colonoscope for repair new for sale, Buy brand new flexible endoscope repair parts for Olympus.Order now!

Olympus CF-240L Colonoscope for repair

$0.00

► Brief Description

Fault: Leakage, glass of light bundle blur, rubber leak, angle not enough,image fuzzle,objective lens scratch.

Solution: Replace rubber, objective lens, C cover. Adjust the angle.

â–ºProblem & Solutoin

Brand Olympus
Model CF-240L
Fault Leakage, glass of light bundle blur, rubber leak, angle not enough,
image fuzzle,objective lens scratch,
Solution Replace rubber, objective lens, C cover. Adjust the angle.

► Common issues with CF-240L Colonoscope

  • Damaged Insertion Tube
  • Worn or Damaged Bending Section
  • Fuzzy or Blocked Image
  • Dark Spots or Broken Pixels
  • Poor Light Transmission
  • Fluid Leaks
  • Blocked Air/Water or Suction Channels
  • Connector Damage

Olympus CF-240L Colonoscope for repair

Olympus CF-240L Colonoscope for repair for sale, Buy brand new flexible endoscope repair parts for Olympus.Order now!

Olympus CF-2T160L Colonoscope for repair

$0.00

► Brief Description

Fault: 

1. With image.

2. 10% light bundle broken.

3. Insert tube is ok.

4. Biopsy tube abrasion.

5. Angle tied, bending section transformation.

6. Wires, helix tube abrasion, no up angle.

Solution:

Replace image bundle; insert tube; biopsy tube; bending mesh and wires; coil pipe; rubber

â–ºProblem & Solutoin

Brand Olympus
Model CF-2T160L
Fault 1. With image. 2. 10% light bundle broken. 3. Insert tube is ok. 4. Biopsy tube abrasion. 5. Angle tied, bending section transformation. 6. Wires, helix tube abrasion, no up angle.
Solution Replace wires, helix tube, bending section and rubber.

► Common issues with CF-2T160L Colonoscope

  • Bending Section Issues
  • Insertion Tube Damage
  • Optical/Image System Problems
  • Fluid Leaks
  • Channel Obstructions
  • Light Guide and Fiber Optic Issues

OLYMPUS CF-2T160L scope for repair

OLYMPUS CF-2T160L scope for repair for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!

Olympus CF-H190L Colonoscope for repair

$0.00

► Brief Description

Fault:

1. Image ok;

2. Light bundle still ok;

3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking;

4. Biopsy tube wear;

5. Left Angle failure, bending section, wire and helix tube wear;

6. Soft and hard adjustment wire wear, relatively tight;

7. Rubber leakage.

Solution:

Replace the insertion tube, biopsy tube, bending section, wire, helix tube, soft and hard adjusting wire and rubber. (No warranty for CCD).

â–ºProblem & Solutoin

Brand Olympus
Model CF-H190L
Fault 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking; 4. Biopsy tube wear; 5. Left Angle failure, bending section, wire and helix tube wear; 6. Soft and hard adjustment wire wear, relatively tight; 7. Rubber leakage.
Solution Replace the insertion tube, biopsy tube, bending section, wire, helix tube, soft and hard adjusting wire and rubber. (No warranty for CCD)

► Common issues with CF-H190L Colonoscope

  • No Image/Black Screen
  • Dim or Uneven Illumination
  • Blurry or Out-of-Focus Image
  • Stiff or Difficult Angulation
  • Leaking or Failed Leak Test
  • Abnormal Angulation
  • Biopsy Channel Obstruction
  • Damaged Bending Rubber
  • Buttons Not Responding
  • Water or Air Channel Issues

Olympus CF-H190L Colonoscope for repair,SN:261****.

Olympus CF-H190L Colonoscope for repair,SN:261****. for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!

Fix Once Right, Save Replacement Costs

Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.

However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.

Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.

If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!