Olympus CYF V2 Cystoscope For Repair
$0.00► Brief Description
Fault:Â Leakage.
Solution:
Replace the insert tube, light bundle, biopsy channel, bending section, wire, steel mesh, rubber.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | CYF V2 |
| Fault | Leakage |
| Solution | Replace the insert tube, light bundle, biopsy channel, bending section, wire, steel mesh, rubber |
► Common issues with CYF V2 Cystoscope
- No Image / Dark Image
- Poor Image Resolution / Blurry Image
- Ineffective Suction
- Difficulty with Angulation (Stiff or Loose)
- Bubbles in the Field of View
- Damaged Insertion Tube or Sheath
Olympus Endoscope Insertion Tube Boot CF-Q160AL
Olympus Endoscope Insertion Tube Boot CF-Q160AL for sale, Buy brand new Flexible Endoscope for OLYMPUS.Order now!
Olympus Endoscope Insertion Tube Boot GIF-H260
Olympus Endoscope Insertion Tube Boot GIF-H260 for sale, Buy brand new Flexible Endoscope for OLYMPUS.Order now!
Olympus ENF-GP fiber nasopharyngeal laryngoscope for repair
$0.00► Brief Description
Fault:
1. Image with black point and image bundle broken
2. Light bundle aged
3. Insert tube aging and wrinkle
4. Bending section deformation
5. Angle with not enough
6. Rubber abrasion
Solution:
Replace image bundle; light bundle; insert tube; wires; helix tube; bending section; rubber
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | ENF-GP |
| Fault | 1. Image with black point and image bundle broken 2. Light bundle aged 3. Insert tube aging and wrinkle 4. Bending section deformation 5. Angle with not enough 6. Rubber abrasion |
| Solution | Replace image bundle; light bundle; insert tube; wires; helix tube; bending section; rubber |
► Common issues with ENF-GP Endoscope
- Bending Section Issues
- Insertion Tube Damage
- Optical/Image System Problems
- Fluid Leaks
- Light Guide and Illumination Issues
OLYMPUS ENF-GP fiber nasopharyngeal laryngoscope for repair; SN: 220****
OLYMPUS ENF-GP fiber nasopharyngeal laryngoscope for repair; SN: 220**** for sale, Buy brand new flexible endoscope repair parts for Olympus.Order now!
Olympus FB-25K-1 Biopsy Forceps
Olympus FB-25K-1 Biopsy Forceps for sale, Buy brand new Flexible Endoscope for Olympus.Order now!
Olympus Flexible Endoscope 2.8MM biopsy tube
Olympus Flexible Endoscope 2.8MM biopsy tube for sale, Buy brand new Flexible Endoscope for OLYMPUS.Order now!
Olympus Flexible Endoscope 3.8MM biopsy tube
Olympus Flexible Endoscope 3.8MM biopsy tube for sale, Buy brand new Flexible Endoscope for OLYMPUS.Order now!
Olympus GF-UCT180 Ultrasound echoendoscope for repair
Olympus GF-UCT180 Ultrasound echoendoscope for repair for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!
Olympus GIF-1TH190 Gastroscope for repair,SN:260****.
Olympus GIF-1TH190 Gastroscope for repair,SN:260****. for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!
Olympus GIF-1TQ160 gastroscope for repair
$0.00► Brief Description
Fault:
1.With image, but CCD with broken.
2.Light bundle broken completely.
3.Insert tube abrasion.
4. No biopsy tube.
5. No air&water tube, no water supply tube.
6. No bending section assembly.
7. No digital tip.
Solution:
Replace CCD, digital tip, light bundle, insert tube,biopsy tube, air&water tube, water supply tube,bending section,wires,helix tube and rubber.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | GIF-1TQ160 |
| Fault | 1.With image, but CCD with broken. 2.Light bundle broken completely. 3.Insert tube abrasion. 4. No biopsy tube. 5. No air&water tube, no water supply tube. 6. No bending section assembly. 7. No digital tip. |
| Solution | Replace CCD, digital tip, light bundle, insert tube,biopsy tube, air&water tube, water supply tube,bending section,wires,helix tube and rubber. |
► Common issues with GIF-1TQ160 gastroscope
- Bending Section and Angulation Issues
- Insertion Tube Damage
- Biopsy/Suction Channel Blockage
- Image Quality Problems
- Air/Water Insufflation Issues
- Fluid Leakage
OLYMPUS GIF-1TQ160 gastroscope for repair
OLYMPUS GIF-1TQ160 gastroscope for repair for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!
OLYMPUS GIF-H170 BIOPSY TUBE
OLYMPUS GIF-H170 BIOPSY TUBE for sale, Buy brand new Flexible Endoscope for OLYMPUS.Order now!
Olympus GIF-H170 gastroscope for repair
$0.00► Brief Description
Fault:
1. The top left and middle right side with blur image, objective Lens broken.
2. 20% light bundle broken, the small lens turned yellow.
3. Insert tube yellow and wrinkles.
4. The biopsy tube abrasion.
5. The wire and helix tube abrasion.
6. Light guide tube aging and wrinkle.
Solution:
Replace objective lens, light bundle, small lens, insert tube, biopsy tube, wires, helix tube, light guide tube and rubber.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | GIF-H170 |
| Fault | 1. The top left and middle right side with blur image, objective Lens broken. 2. 20% light bundle broken, the small lens turned yellow. 3. Insert tube yellow and wrinkles. 4. The biopsy tube abrasion. 5. The wire and helix tube abrasion. 6. Light guide tube aging and wrinkle. |
| Solution | Replace objective lens, light bundle, small lens, insert tube, biopsy tube, wires, helix tube, light guide tube and rubber. |
► Common issues with GIF-H170 gastroscope
- Insertion Tube Damage
- Light Guide Fiber Breakage
- Image Sensor Failure (CCD/CMOS)
- Angulation Control Issues
- Water/Air Channel Blockage
- Biopsy Channel Blockage or Leakage
- Distal Tip Damage
- Fluid Leakage
OLYMPUS GIF-H170 SN:293****
OLYMPUS GIF-H170 SN:293**** for sale, Buy brand new flexible endoscope repair parts for Olympus.Order now!
Olympus GIF-H180J gastroscope for repair
$0.00► Brief Description
Fault:
1.image with shadow;
2.light bundle broken;
3.insert tube with bite mark;
4.biopsy tube abrasion;
5.bending section serious deformation;
6.wires and helix tube abrasion;
7.light guide tube aging and wrinkle.
Solution:
Replace CCD, light bundle, insert tube,biopsy tube,aire&water tube,bending section,wires,helix tube,light guide tube and rubber.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | GIF-H180J |
| Fault | 1.image with shadow; 2.light bundle broken; 3.insert tube with bite mark; 4.biopsy tube abrasion; 5.bending section serious deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. |
| Solution | Replace CCD, light bundle, insert tube,biopsy tube,aire&water tube,bending section,wires,helix tube,light guide tube and rubber. |
► Common issues with GIF-H180J gastroscope
- Image and Optical Problems
- Bending Section Issues
- Air/Water Channel Problems
- Suction Channel Problems
- External Damage and Wear
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!