SHOP
Product Categories
- NEW PRODUCT 5
- Parts for Anesthesia 0
- Parts for Camera system 81
- Parts for Defibrillator 0
- Parts for Dynamical System 86
- Parts for Flexible Endoscope 306
- Parts for Microplate Reader 1
- Parts for Monitor 4
- Parts for MRI 0
- Parts for Rigid Endoscope 11
- Parts for Surgical Instrument 46
- Parts for Ultrasound & Probe 87
- Parts for Ventilator 89
- PCR and Centrifuge 8
- Repair Cases 172
- Repair Tools 21
Filter by brand
Filter by price
Featured Products
Showing 513–528 of 917 results
Olympus CCD For GIF-Q260 Gastroscope
Olympus CCD For GIF-Q260 Gastroscope for sale, Buy brand new Flexible Endoscope for OLYMPUS.Order now!
Olympus CCD For GIF-XQ260 Gastroscope
Olympus CCD For GIF-XQ260 Gastroscope for sale, Buy brand new Flexible Endoscope for OLYMPUS.Order now!
Olympus CCD for GIF-XQ260 Gastroscope
Olympus CCD for GIF-XQ260 Gastroscope for sale, Buy brand new Flexible Endoscope for OLYMPUS.Order now!
Olympus CF-240AI Colonoscope for repair
$0.00► Brief Description
Fault:
Image blur,insert tube aging,light guide squashed,light guide broken 50%,nozzle blocked,angle tight,forceps channel aging.
Solution:
Replace insertion tube,CCD chips,light guide,forceps channel,water channel,angulation wire,bending mesh,spiral tube,light guide tube,bending rubber.
►Problem & Solutoin
| Brand | Olympus |
| Model | CF-240AI |
| Fault | Image blur,insert tube aging,light guide squashed,light guide broken 50%,nozzle blocked,angle tight,forceps channel aging. |
| Solution | Replace insertion tube,CCD chips,light guide,forceps channel,water channel,angulation wire,bending mesh,spiral tube,light guide tube,bending rubber. |
► Common issues with CF-240AI Colonoscope
- Insertion Tube Damage
- Image Quality Issues
- Mechanism Failures
- Connector and Light Source Issues
Olympus CF-240AI Colonoscope for repair
Olympus CF-240AI Colonoscope for repair for sale, Buy brand new flexible endoscope repair parts for Olympus.Order now!
Olympus CF-240AI Colonoscope for repair new
Olympus CF-240AI Colonoscope for repair new for sale, Buy brand new flexible endoscope repair parts for Olympus.Order now!
Olympus CF-240L Colonoscope for repair
$0.00► Brief Description
Fault: Leakage, glass of light bundle blur, rubber leak, angle not enough,image fuzzle,objective lens scratch.
Solution: Replace rubber, objective lens, C cover. Adjust the angle.
►Problem & Solutoin
| Brand | Olympus |
| Model | CF-240L |
| Fault | Leakage, glass of light bundle blur, rubber leak, angle not enough, image fuzzle,objective lens scratch, |
| Solution | Replace rubber, objective lens, C cover. Adjust the angle. |
► Common issues with CF-240L Colonoscope
- Damaged Insertion Tube
- Worn or Damaged Bending Section
- Fuzzy or Blocked Image
- Dark Spots or Broken Pixels
- Poor Light Transmission
- Fluid Leaks
- Blocked Air/Water or Suction Channels
- Connector Damage
Olympus CF-240L Colonoscope for repair
Olympus CF-240L Colonoscope for repair for sale, Buy brand new flexible endoscope repair parts for Olympus.Order now!
Olympus CF-2T160L Colonoscope for repair
$0.00► Brief Description
Fault:
1. With image.
2. 10% light bundle broken.
3. Insert tube is ok.
4. Biopsy tube abrasion.
5. Angle tied, bending section transformation.
6. Wires, helix tube abrasion, no up angle.
Solution:
Replace image bundle; insert tube; biopsy tube; bending mesh and wires; coil pipe; rubber
►Problem & Solutoin
| Brand | Olympus |
| Model | CF-2T160L |
| Fault | 1. With image. 2. 10% light bundle broken. 3. Insert tube is ok. 4. Biopsy tube abrasion. 5. Angle tied, bending section transformation. 6. Wires, helix tube abrasion, no up angle. |
| Solution | Replace wires, helix tube, bending section and rubber. |
► Common issues with CF-2T160L Colonoscope
- Bending Section Issues
- Insertion Tube Damage
- Optical/Image System Problems
- Fluid Leaks
- Channel Obstructions
- Light Guide and Fiber Optic Issues
OLYMPUS CF-2T160L scope for repair
OLYMPUS CF-2T160L scope for repair for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!
OLYMPUS CF-H180AL Electronic Colonoscope For Repair
► Brief Description
Inspection Results:
1. The image is dark, and the CCD is aged.
2. One branch of the light beam is disconnected.
3. The insertion tube is aged and wrinkled.
4. The lower angle is malfunctioning, the other angles are tight, and the snake bone is deformed.
5. The light guide tube is slightly wrinkled.
Solution:
Repair and Replacement: CCD, light bundle, insertion tube, biopsy tube, snake bone, steel wire, helix tube, light guide tube, rubber.
Olympus CF-H190L Colonoscope for repair
$0.00► Brief Description
Fault:
1. Image ok;
2. Light bundle still ok;
3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking;
4. Biopsy tube wear;
5. Left Angle failure, bending section, wire and helix tube wear;
6. Soft and hard adjustment wire wear, relatively tight;
7. Rubber leakage.
Solution:
Replace the insertion tube, biopsy tube, bending section, wire, helix tube, soft and hard adjusting wire and rubber. (No warranty for CCD).
►Problem & Solutoin
| Brand | Olympus |
| Model | CF-H190L |
| Fault | 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking; 4. Biopsy tube wear; 5. Left Angle failure, bending section, wire and helix tube wear; 6. Soft and hard adjustment wire wear, relatively tight; 7. Rubber leakage. |
| Solution | Replace the insertion tube, biopsy tube, bending section, wire, helix tube, soft and hard adjusting wire and rubber. (No warranty for CCD) |
► Common issues with CF-H190L Colonoscope
- No Image/Black Screen
- Dim or Uneven Illumination
- Blurry or Out-of-Focus Image
- Stiff or Difficult Angulation
- Leaking or Failed Leak Test
- Abnormal Angulation
- Biopsy Channel Obstruction
- Damaged Bending Rubber
- Buttons Not Responding
- Water or Air Channel Issues
Olympus CF-H190L Colonoscope for repair,SN:261****.
Olympus CF-H190L Colonoscope for repair,SN:261****. for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!
OLYMPUS CF-H190L Colonoscope SN: 240**** for Repair
OLYMPUS CF-H190L Colonoscope SN: 240**** for Repair for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!
OLYMPUS CF-HQ290L COIL PIPE ASSEMBLY
OLYMPUS CF-HQ290L COIL PIPE ASSEMBLY for sale, Buy brand new Flexible Endoscope for OLYMPUS.Order now!
Olympus CF-Q160AL Colonoscope for repair
$0.00► Brief Description
Fault:
1.No image, CCD broken;
2.image broken completely;
3.insert tube aging;
4.biopsy tube abrasion;
5.bending section abrasion;
6.wires and helix tube abrasion;
7.light guide tube aging and wrinkle.
Solution:
Replace CCD, light bundle, insert tube,biopsy tube,aire&water tube,bending section,wires,helix tube,light guide tube,all the fstener part,clamp and rubber.
►Problem & Solutoin
| Brand | Olympus |
| Model |
CF-Q160AL |
| Fault | 1. With image. 2. 10% light bundle broken. 3. Insert tube is ok. 4. Biopsy tube abrasion. 5. Angle tied, bending section transformation. 6. Wires, helix tube abrasion, no up angle. |
| Solution | Replace wires, helix tube, bending section and rubber. |
► Common issues with CF-Q160AL Colonoscope
- Bending Section Issues
- Insertion Tube Damage
- Optical/Image System Problems
- Fluid Leaks
- Channel Obstructions
- Light Guide and Fiber Optic Issues
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!