OLYMPUS T3925/T3775/T3905/T3105/T3915 LAPAROSCOPIC SCISSORS
OLYMPUS T3925/T3775/T3905/T3105/T3915 LAPAROSCOPIC SCISSORS for sale, Buy brand new PCR and Centrifuge for Olympus.Order now!
Olympus TJF-160VR endoscope for repair
$0.00► Brief Description
Fault:
1.No image, CCD broken.
2. Light bundle broken completely.
3. Insert tube aging and wrinkle.
4. Biopsy tube broken.
5. Wires and helix tube broken.
6. clamp wires broken.
7. Operation part broken, no angle.
8. Grip broken.
9. The scope be separated by someone before, some parts missing.
Solution:
Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube, clamp wires,grip,operation part and rubber.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | TJF-160VR |
| Fault | 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The scope be separated by someone before, some parts missing. |
| Solution | Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube, clamp wires,grip,operation part and rubber. |
► Common issues with TJF-160VR endoscope
- Elevator Mechanism Problems
- Bending Section Issues
- Image and Optical Problems
- Channel Problems (Air, Water, Suction)
- External Damage and Wear
OLYMPUS TJF-160VR endoscope for repair,SN: 250****.
OLYMPUS TJF-160VR endoscope for repair,SN: 250****. for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!
OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR
$0.00► Brief Description
Fault:
1. Image ok;
2. Light bundlestill ok;
3. Insert tubestill ok;
4. Biopsy tubewear;
5. Bendingsection, wires and helix tube wear;
6. Knob leakage.
Solution:
Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD).
â–ºProblem & Solutoin
| Brand | OLYMPUS |
| Model | TJF-Q180V |
| Fault | 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. Bendingsection, wires and helix tube wear; 6. Knob leakage. |
| Solution | Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD) |
► Common issues with TJF-Q180V DUODENOSCOPE
- Fluid Leaks
- Contamination and Foreign Material
- Blocked Channels
- Angulation Wire Damage
- Worn Bending Section
- Forceps Elevator Failure
- Foggy or Blurred Image
- Fiber Optic Damage
OLYMPUS TJF-Q180V DUODENOSCOPE SN:270**** FOR REPAIR
OLYMPUS TJF-Q180V DUODENOSCOPE SN:270**** FOR REPAIR for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!
OLYMPUS WA50200A VIDEO URETEROSCOPE
OLYMPUS WA50200A VIDEO URETEROSCOPE for sale, Buy brand new Figid Endoscope for .Order now!
Olympus/Wolf/Starz/ShenDa Nephrology Forceps
Olympus/Wolf/Starz/ShenDa Nephrology Forceps for sale, Buy brand new PCR and Centrifuge for Olympus/Wolf/Starz/ShenDa.Order now!
ON/OFF KEY SWITCH FOR OLYMPUS CLV-260/ CV-260 LIGHT SOURCE
ON/OFF KEY SWITCH FOR OLYMPUS CLV-260/ CV-260 LIGHT SOURCE for sale, Buy brand new Camera system for OLYMPUS.Order now!
ON/OFF KEY SWITCH FOR STRYKER 1188HD VIDEO CAMERA
ON/OFF KEY SWITCH FOR STRYKER 1188HD VIDEO CAMERA for sale, Buy brand new Camera system for STRYKER.Order now!
ON/OFF KEY SWITCH FOR STRYKER 1188HD VIDEO CAMERA
ON/OFF KEY SWITCH FOR STRYKER 1188HD VIDEO CAMERA for sale, Buy brand new Camera system for STRYKER.Order now!
Original Cable With Motor For Medtronic StraightShot M5/18-99200T M5 Microdebrider Handpiece
$0.00► Brief Description
The cable connects the StraightShot M5 Microdebrider Handpiece (motor) to the Medtronic Integrated Power Console (IPC), enabling the handpiece’s advanced functions.
► Features
- Power & Control Transmission of Power: Delivers electrical power from the IPC console to the handpiece’s direct-drive motor.
- Data Transmission System Integration: Transmits control signals and motor feedback between the handpiece and the IPC console.
- Suction Integration Straight-Through Suction Path: The cable design often incorporates a path or connection for suction tubing.
- Ergonomics & Flexibility Optimized Length/Flexibility: Designed to be lightweight and flexible to minimize drag and interference during delicate surgical procedures.
- Durability Surgical Grade Material: Constructed with materials designed to withstand repeated cleaning, sterilization (usually steam autoclave), and the rigors of the operating room environment.
► Specification
| Brand | Medtronic |
| Model | M5/18-99200T M5 |
| Condition | Brand new |
| Series | Cable With Motor |
| Maximum Speed | Up to 30,000 RPM |
| Motor Type | Direct-Drive Motor |
| Compatibility | IPCâ„¢ System |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Original Distal Head for Olympus CF-HQ290I Colonoscope Parts
Original Distal Head for Olympus CF-HQ290I Colonoscope Parts for sale, Buy brand new Flexible Endoscope for Olympus.Order now!
Original Distal Head for Olympus GIF-HQ290 Gastroscope Parts
Original Distal Head for Olympus GIF-HQ290 Gastroscope Parts for sale, Buy brand new Flexible Endoscope for Olympus.Order now!
OrIginal new 2.00MM Biopsy tube for Pentax Endoscope
OrIginal new 2.00MM Biopsy tube for Pentax Endoscope for sale, Buy brand new Flexible Endoscope for PENTAX.Order now!
Original New Olympus MAJ-1500 Waterproof Connector
$0.00► Brief Description
The Olympus MAJ-1500 is typically a crucial Waterproof Connector (or Pigtail Connector) designed to interface Olympus flexible endoscopes (often the EVIS EXERA III 190 series) with the light source and video processing unit (like the CLV-190 and CV-190).
► Features
- Video Signal: Transfers the digital image signal from the scope’s CCD/CMOS chip to the CV-190 Video Processor for processing and display.
- Control Signals: Carries electronic signals related to remote scope controls (e.g., shutter, scope function buttons) back to the processor.
- Light Transmission: Connects the CLV-190 Light Source’s fiber optic cable to the endoscope’s light guide bundle, ensuring bright, consistent illumination in the patient’s body cavity.
- Fluid Channeling: Provides sealed pathways for the delivery of air (for insufflation) and water (for lens washing/jet function) from the pump system to the endoscope tip.
- Reprocessing Interface: It serves as the point where the Leak Tester (like the MB-155 cable) is connected. This allows pressure to be introduced into the scope’s channels before cleaning to verify its waterproof integrity.
► Specification
| Brand | Olympus |
| Condition | Original & new |
| Series | Waterproof Connector |
| Model | MAJ-1500 |
| Material | Durable |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Â
Original New Olympus MH-155 White Balance Cap For Flexible Endoscopes
$0.00â–º Brief Description
Olympus MH-155Â Used to set the accurate white balance for the endoscope’s camera system before a procedure. This ensures that the colors of tissues and organs viewed during endoscopy are displayed correctly on the monitor.
► Features
- Color Accuracy:Â Its main purpose is to provide a uniform white reference surface for the endoscope’s video processor. When the scope is aimed at the MH-155 and the white balance function is activated, the system calibrates the video signal, ensuring all other colors (like the red of blood or the pink of tissue) are correctly rendered.
- Image Optimization:Â Proper white balance is crucial for high-quality endoscopic imaging, aiding clinicians in accurate diagnosis and identification of pathological changes.
► Specification
| Brand | Olympus |
| Model | MH-155 |
| Condition | Original & new |
| Primary Function | White Balance Adjustment |
| Product Type | Balance Cap |
| Color | White |
| Reusability | Reusable |
| Compatibility | Olympus Endoscopes |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!