SHOP
Product Categories
- NEW PRODUCT 5
- Parts for Anesthesia 0
- Parts for Camera system 81
- Parts for Defibrillator 0
- Parts for Dynamical System 86
- Parts for Flexible Endoscope 306
- Parts for Microplate Reader 1
- Parts for Monitor 4
- Parts for MRI 0
- Parts for Rigid Endoscope 11
- Parts for Surgical Instrument 46
- Parts for Ultrasound & Probe 87
- Parts for Ventilator 89
- PCR and Centrifuge 8
- Repair Cases 172
- Repair Tools 21
Filter by brand
Filter by price
Featured Products
Showing 609–624 of 917 results
OLYMPUS T3925/T3775/T3905/T3105/T3915 LAPAROSCOPIC SCISSORS
OLYMPUS T3925/T3775/T3905/T3105/T3915 LAPAROSCOPIC SCISSORS for sale, Buy brand new PCR and Centrifuge for Olympus.Order now!
Olympus TJF-160VR endoscope for repair
$0.00► Brief Description
Fault:
1.No image, CCD broken.
2. Light bundle broken completely.
3. Insert tube aging and wrinkle.
4. Biopsy tube broken.
5. Wires and helix tube broken.
6. clamp wires broken.
7. Operation part broken, no angle.
8. Grip broken.
9. The scope be separated by someone before, some parts missing.
Solution:
Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube, clamp wires,grip,operation part and rubber.
►Problem & Solutoin
| Brand | Olympus |
| Model | TJF-160VR |
| Fault | 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The scope be separated by someone before, some parts missing. |
| Solution | Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube, clamp wires,grip,operation part and rubber. |
► Common issues with TJF-160VR endoscope
- Elevator Mechanism Problems
- Bending Section Issues
- Image and Optical Problems
- Channel Problems (Air, Water, Suction)
- External Damage and Wear
OLYMPUS TJF-160VR endoscope for repair,SN: 250****.
OLYMPUS TJF-160VR endoscope for repair,SN: 250****. for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!
OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR
$0.00► Brief Description
Fault:
1. Image ok;
2. Light bundlestill ok;
3. Insert tubestill ok;
4. Biopsy tubewear;
5. Bendingsection, wires and helix tube wear;
6. Knob leakage.
Solution:
Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD).
►Problem & Solutoin
| Brand | OLYMPUS |
| Model | TJF-Q180V |
| Fault | 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. Bendingsection, wires and helix tube wear; 6. Knob leakage. |
| Solution | Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD) |
► Common issues with TJF-Q180V DUODENOSCOPE
- Fluid Leaks
- Contamination and Foreign Material
- Blocked Channels
- Angulation Wire Damage
- Worn Bending Section
- Forceps Elevator Failure
- Foggy or Blurred Image
- Fiber Optic Damage
OLYMPUS TJF-Q180V DUODENOSCOPE SN:270**** FOR REPAIR
OLYMPUS TJF-Q180V DUODENOSCOPE SN:270**** FOR REPAIR for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!
OLYMPUS TJF-Q180V Electronic Duodenoscope For Repair
► Brief Description
Inspection Results:
1. Image display is available;
2. The light bundle brightness is acceptable;
3. The insertion tube is worn;
4. The light guide tube is worn;
5. The angle is insufficient, the snake bone, steel wire and helix tube are worn;
6. The forceps elevator handle is damaged;
7. The handle shell is severely cracked.
Solution:
Replacement: Insertion tube, handle shell, light guide tube, snake bone, steel wire, helix tube, lifting clamp handle, rubber. CCD is not covered by warranty.
OLYMPUS WA50200A VIDEO URETEROSCOPE
OLYMPUS WA50200A VIDEO URETEROSCOPE for sale, Buy brand new Figid Endoscope for .Order now!
Olympus/Wolf/Starz/ShenDa Nephrology Forceps
Olympus/Wolf/Starz/ShenDa Nephrology Forceps for sale, Buy brand new PCR and Centrifuge for Olympus/Wolf/Starz/ShenDa.Order now!
ON/OFF KEY SWITCH FOR OLYMPUS CLV-260/ CV-260 LIGHT SOURCE
ON/OFF KEY SWITCH FOR OLYMPUS CLV-260/ CV-260 LIGHT SOURCE for sale, Buy brand new Camera system for OLYMPUS.Order now!
ON/OFF KEY SWITCH FOR STRYKER 1188HD VIDEO CAMERA
ON/OFF KEY SWITCH FOR STRYKER 1188HD VIDEO CAMERA for sale, Buy brand new Camera system for STRYKER.Order now!
ON/OFF KEY SWITCH FOR STRYKER 1188HD VIDEO CAMERA
ON/OFF KEY SWITCH FOR STRYKER 1188HD VIDEO CAMERA for sale, Buy brand new Camera system for STRYKER.Order now!
Original Cable With Motor For Medtronic StraightShot M5/18-99200T M5 Microdebrider Handpiece
$0.00► Brief Description
The cable connects the StraightShot M5 Microdebrider Handpiece (motor) to the Medtronic Integrated Power Console (IPC), enabling the handpiece’s advanced functions.
► Features
- Power & Control Transmission of Power: Delivers electrical power from the IPC console to the handpiece’s direct-drive motor.
- Data Transmission System Integration: Transmits control signals and motor feedback between the handpiece and the IPC console.
- Suction Integration Straight-Through Suction Path: The cable design often incorporates a path or connection for suction tubing.
- Ergonomics & Flexibility Optimized Length/Flexibility: Designed to be lightweight and flexible to minimize drag and interference during delicate surgical procedures.
- Durability Surgical Grade Material: Constructed with materials designed to withstand repeated cleaning, sterilization (usually steam autoclave), and the rigors of the operating room environment.
► Specification
| Brand | Medtronic |
| Model | M5/18-99200T M5 |
| Condition | Brand new |
| Series | Cable With Motor |
| Maximum Speed | Up to 30,000 RPM |
| Motor Type | Direct-Drive Motor |
| Compatibility | IPC™ System |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Original Distal Head for Olympus CF-HQ290I Colonoscope Parts
Original Distal Head for Olympus CF-HQ290I Colonoscope Parts for sale, Buy brand new Flexible Endoscope for Olympus.Order now!
Original Distal Head for Olympus GIF-HQ290 Gastroscope Parts
Original Distal Head for Olympus GIF-HQ290 Gastroscope Parts for sale, Buy brand new Flexible Endoscope for Olympus.Order now!
OrIginal new 2.00MM Biopsy tube for Pentax Endoscope
OrIginal new 2.00MM Biopsy tube for Pentax Endoscope for sale, Buy brand new Flexible Endoscope for PENTAX.Order now!
Original New CITY MOX1 Oxygen Sensor For Ventilator
► Brief Description
The CITY MOX1 is a high-precision oxygen sensor designed specifically for medical applications, such as in ventilators and anesthesia machines. It utilizes a partial pressure electrochemical principle to measure oxygen concentration, ensuring accurate and reliable monitoring of oxygen levels in critical care environments.
►Features
- Accurate Oxygen Concentration Measurement
- Fast Response Time
- Temperature Compensation
- Long-Term Stability
- Wide Operating Range
► Specification
| Brand | CITY |
| Model | MOX1 |
| Condition | Original & new |
| Series | Oxygen Sensor |
| Operating Principle | Partial pressure electrochemical |
| Response Time | Less than 15 seconds (from air to 100% O₂) |
| Operating Temperature Range | -20°C to +50°C |
| Operating Pressure Range | 0.5 Bar to 2.0 Bar |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!