Olympus GIF-Q150 gastroscope for repair
$0.00► Brief Description
Fault:
1.with image;
2.one eye of light bundle broken;
3.insert tube little aging;
4.biopsy tube abrasion;
5.bending section deformation;
6.wires and helix tube abrasion;
7.light guide tube aging and wrinkle.
Solution:
Replace light bundle ,insert tube, biopsy tube,bending section,wires,helix tube,light guide tube and rubber.
â–ºProblem & Solutoin
| Brand | OLYMPUS |
| Model | GIF-Q150 |
| Fault | 1.with image; 2.one eye of light bundle broken; 3.insert tube little aging; 4.biopsy tube abrasion; 5.bending section deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. |
| Solution | Replace light bundle ,insert tube, biopsy tube,bending section,wires,helix tube,light guide tube and rubber. |
► Common issues with GIF-Q150 gastroscope
- Bending Section Issues
- Image and Optical Problems
- Air/Water Channel Problems
- Suction Channel Problems
- External Damage and Wear
Olympus GIF-Q180 gastroscope for repair
$0.00► Brief Description
Fault:
1.image definition not enough, CCD aging.
2.30% light bundle broken.
3. Insert tube aging and wrinkle.
4.Biopsy tube abrasion.
5. Bending section bited, transformation.
6. Angle not enough, wires and helix tube abrasion.
7. Light guide tube aging and wrinkle.
8. Pins for wire holder leakage.
Solution:
Replace CCD, light bundle,insert tube, biopsy tube, bending section,helix tube, wires, light guide tube, pins and rubber.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | GIF-Q180 |
| Fault | 1.image definition not enough, CCD aging. 2.30% light bundle broken. 3. Insert tube aging and wrinkle. 4.Biopsy tube abrasion. 5. Bending section bited, transformation. 6. Angle not enough, wires and helix tube abrasion. 7. Light guide tube aging and wrinkle. 8. Pins for wire holder leakage. |
| Solution | Replace CCD, light bundle,insert tube, biopsy tube, bending section,helix tube, wires, light guide tube, pins and rubber. |
► Common issues with GIF-Q180 gastroscope
- Image and Optical Problems
- Bending Section Issues
- Air/Water Channel Problems
- Suction Channel Problems
- External Damage and Wear
Olympus LTF-160 thoracoscope for repair
$0.00► Brief Description
Fault:
1.with image, but big risk for CCD after leakage.
2. Light bundle broken completely.
3. Insert tube with little scratch.
4. Biopsy tube abrasion and leakage.
5. Wires and helix tube abrasion.
6. Grip broken, leakage.
7. All the buttons failure.
8. Rubber leakage.
9. the whole scope leakage.
Solution:
Replace CCD,light bundle, biopsy tube, wires,helix tube,grip and rubber, repair all the buttons.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | LTF-160 |
| Fault | 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the buttons failure. 8. Rubber leakage. 9. the whole scope leakage. |
| Solution | Replace CCD,light bundle, biopsy tube, wires,helix tube,grip and rubber, repair all the buttons. |
► Common issues with LTF-160 thoracoscope
- Image and Optical Problems
- Bending Section and Tip Issues
- Channel Problems (Suction, Biopsy)
- External Damage and Wear
Olympus MAJ-1121 Transducer Handpiece
$0.00► Brief Description
The MAJ-1121 is a dedicated Remote Signal Cable designed for medical endoscopy systems. It serves as the communication bridge between the Olympus Video Processor and peripheral imaging devices.
â–ºFeatures
- Signal Transmission: It relays trigger signals from the remote switches (buttons) located on the endoscope handle to external equipment.
- Workflow Integration:Â Enables the endoscopist to control capturing, printing, or recording without having to touch the peripheral device manually.
- Customizable Mapping:Â Through the Video Processor menu, users can assign different functions (e.g., Freeze, Release, VTR, Print) to specific buttons on the scope handle.
- Plug-and-Play:Â Once the “Remote” port is configured in the system settings, the cable provides an instantaneous response.
- High Reliability:Â Designed with shielding to prevent electromagnetic interference (EMI) from other surgical equipment in the OR or GI suite.
► Specification
| Brand | Olympus |
| Model | MAJ-1121 |
| Condition | Working in Good Condition |
| Series | Transducer Handpiece |
| Compatibility | Olympus CV-140, CV-160, CV-180, and CV-190 Series |
| Standard Length | Approx. 1.8 meters (6 feet) |
| Outer Sheath | Medical-grade PVC (Flexible and durable) |
| Signal Type | Dry contact / Digital TTL trigger signals |
| Connector Type | 14-pin (Round/Circular) Multi-pin Connector |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
OLYMPUS MB-146 SILICONE OIL ENDOSCOPE LUBRICANT
$0.00► Brief Description Â
The MB-146 is a silicone-based lubricant used to ensure the O-rings and detachable parts of Olympus endoscopes remain flexible, create a secure seal, and operate smoothly during clinical use and cleaning/disinfection cycles.
► Features
- Role:Â It is an inert lubricant designed specifically for use with endoscope components.
- Application:Â It is typically applied to the O-rings, valve buttons, and connecting parts (such as those for the water bottle) of endoscopes.
- Benefit:Â Proper lubrication is essential for smooth operation of the endoscope’s controls and for maintaining a proper seal between components, which is critical for the function and water-resistance of the instrument during procedures and reprocessing.
► Specification
| Brand | OLYMPUS |
| Model | MB-146 |
| Condition | Original & new |
| Series | Silicone Oil Lubricant |
| Form | Clear liquid/oil |
| Intended Use | Endoscope Lubrication |
| Packaging | Typically a 15 mL bottle |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
OLYMPUS OTV-S6H-1D Camera Head For Repair
$0.00► Brief Description
Fault:
1.Image yes.
2.Cable aging and interference
Solution:Â Replace new cable.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | OTV-S6H-1D |
| Fault | Cable aging and interference |
| Solution | Replace cable |
► Applications
- Laparoscopy (abdominal surgery)
- Arthroscopy (joint surgery)
- ENT (Ear, Nose, Throat) procedures
- General endoscopic imaging
► Troubleshooting & Support
- Cable connections (damage or loose connections).
- Light source compatibility (requires Olympus or compatible systems).
- Sterilization damage (excessive heat or chemical exposure).
Olympus ShockPULSE-SE Lithotripsy Handpiece SPL-T For Repair
$0.00► Brief Description
Fault:
1.No ultrasonic energy output.
Ultrasonic crystal is damaged.
Solution:Â Replace the ultrasonic crystal.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | SPL-T |
| Ultrasonic crystal | Damaged |
| Fault | No ultrasonic energy output |
| Solution | Replace the ultrasonic crystal |
Olympus SonoSurg-T2H-C Ultrasonic Transducer
$0.00► Brief Description
The SonoSurg-T2H-C is a high-performance handheld transducer (handpiece) that converts electrical energy from the generator into mechanical longitudinal vibrations.
â–ºFeatures
- Energy Conversion:Â Utilizes piezoelectric ceramic elements to generate ultrasonic waves.
- Surgical Action:Â When attached to a compatible probe (scissors or blade), it enables simultaneous cutting and coagulation (hemostasis) of soft tissue using frictional heat.
- Suction Capability:Â Designed with an internal channel to support smoke and fluid evacuation during laparoscopic or open procedures.
► Specification
| Brand | Olympus |
| Model | SonoSurg-T2H-C |
| Condition | Brand new |
| Series | Ultrasonic Transducer |
| Operating Frequency | Approximately 23.5kHz |
| Generator Compatibility | Olympus SonoSurg G2 |
| Vibration Mode | Longitudinal Ultrasonic Vibration |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Olympus TJF-160VR endoscope for repair
$0.00► Brief Description
Fault:
1.No image, CCD broken.
2. Light bundle broken completely.
3. Insert tube aging and wrinkle.
4. Biopsy tube broken.
5. Wires and helix tube broken.
6. clamp wires broken.
7. Operation part broken, no angle.
8. Grip broken.
9. The scope be separated by someone before, some parts missing.
Solution:
Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube, clamp wires,grip,operation part and rubber.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | TJF-160VR |
| Fault | 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The scope be separated by someone before, some parts missing. |
| Solution | Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube, clamp wires,grip,operation part and rubber. |
► Common issues with TJF-160VR endoscope
- Elevator Mechanism Problems
- Bending Section Issues
- Image and Optical Problems
- Channel Problems (Air, Water, Suction)
- External Damage and Wear
OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR
$0.00► Brief Description
Fault:
1. Image ok;
2. Light bundlestill ok;
3. Insert tubestill ok;
4. Biopsy tubewear;
5. Bendingsection, wires and helix tube wear;
6. Knob leakage.
Solution:
Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD).
â–ºProblem & Solutoin
| Brand | OLYMPUS |
| Model | TJF-Q180V |
| Fault | 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. Bendingsection, wires and helix tube wear; 6. Knob leakage. |
| Solution | Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD) |
► Common issues with TJF-Q180V DUODENOSCOPE
- Fluid Leaks
- Contamination and Foreign Material
- Blocked Channels
- Angulation Wire Damage
- Worn Bending Section
- Forceps Elevator Failure
- Foggy or Blurred Image
- Fiber Optic Damage
Original New Olympus MAJ-1500 Waterproof Connector
$0.00► Brief Description
The Olympus MAJ-1500 is typically a crucial Waterproof Connector (or Pigtail Connector) designed to interface Olympus flexible endoscopes (often the EVIS EXERA III 190 series) with the light source and video processing unit (like the CLV-190 and CV-190).
► Features
- Video Signal: Transfers the digital image signal from the scope’s CCD/CMOS chip to the CV-190 Video Processor for processing and display.
- Control Signals: Carries electronic signals related to remote scope controls (e.g., shutter, scope function buttons) back to the processor.
- Light Transmission: Connects the CLV-190 Light Source’s fiber optic cable to the endoscope’s light guide bundle, ensuring bright, consistent illumination in the patient’s body cavity.
- Fluid Channeling: Provides sealed pathways for the delivery of air (for insufflation) and water (for lens washing/jet function) from the pump system to the endoscope tip.
- Reprocessing Interface: It serves as the point where the Leak Tester (like the MB-155 cable) is connected. This allows pressure to be introduced into the scope’s channels before cleaning to verify its waterproof integrity.
► Specification
| Brand | Olympus |
| Condition | Original & new |
| Series | Waterproof Connector |
| Model | MAJ-1500 |
| Material | Durable |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Â
Original New Olympus MH-155 White Balance Cap For Flexible Endoscopes
$0.00â–º Brief Description
Olympus MH-155Â Used to set the accurate white balance for the endoscope’s camera system before a procedure. This ensures that the colors of tissues and organs viewed during endoscopy are displayed correctly on the monitor.
► Features
- Color Accuracy:Â Its main purpose is to provide a uniform white reference surface for the endoscope’s video processor. When the scope is aimed at the MH-155 and the white balance function is activated, the system calibrates the video signal, ensuring all other colors (like the red of blood or the pink of tissue) are correctly rendered.
- Image Optimization:Â Proper white balance is crucial for high-quality endoscopic imaging, aiding clinicians in accurate diagnosis and identification of pathological changes.
► Specification
| Brand | Olympus |
| Model | MH-155 |
| Condition | Original & new |
| Primary Function | White Balance Adjustment |
| Product Type | Balance Cap |
| Color | White |
| Reusability | Reusable |
| Compatibility | Olympus Endoscopes |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Philips L12-3 linear Probe for repair
$0.00► Brief Description
Fault:Â Array element aging, lens bubble.
Solution:Â Replace Crystal.
â–ºProblem & Solutoin
| Brand | Philips |
| Model | L12-3 |
| Fault | Array element aging, lens bubble |
| Solution | Replace Crystal |
► Common issues with L12-3 Probe
- Image Dropout:
- Shadows
- Dual Images
- Cable Jacket Damage
- Connector Damage
- Strain Relief Separation
- Membrane/Lens Damage
Pre-owend Nozzle For Olympus GIF-H170 Gastroscope
$0.00â–º Brief Description
For the Olympus GIF-H170 (Optera series) gastroscope, the “nozzle” typically refers to the air/water located at the distal tip of the scope.
► Features
- Lens Cleaning (Irrigation) :When the air/water valve is fully depressed, the nozzle directs a high-pressure stream of water across the objective lens.
- Air Insufflation:When the air/water valve hole is covered (without being fully depressed), the nozzle pumps air into the patient’s stomach or esophagus.
- Maintenance of Field of View:Continuous or intermittent air flow helps prevent the collapse of the organ walls around the distal tip.
â–º Specification
| Brand | Olympus |
| Model | GIF-H170 |
| Serise | Nozzle |
| Condition | Working in Good Condition |
| Material | High-grade medical stainless steel |
| Tip Diameter | 9.2 mm |
| Nozzle Type | Single-nozzle dual-channel |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Water-Resistant Cap MH-553 For Olympus Flexible Video Endoscopes
$0.00► Brief Description
The Olympus MH-553 is a critical accessory used in medical endoscopy, specifically designed as a Water-Resistant Cap (also known as a Soaking Cap or Leak Test Cap). Its primary purpose is to protect the sensitive electrical connectors of a flexible endoscope during the cleaning, disinfection, and sterilization processes.
► Features
- Water Ingress Protection
- Leakage Testing Support
- Reprocessing Safety
- Compatibility with ETO Sterilization
► Specification
| Brand | Olympus |
| Model | MH-553 |
| Condition | Original & new |
| Series | Water-Resistant Cap |
| Compatibility | EVIS Series (100, 130, 140, 160, 180, 190, 200, 240, 260) |
| Device Type | Flexible Video Endoscopes |
| Material | Medical-grade high-durability plastic |
| Attachment Point | Electrical connector |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!