Olympus
Product Categories
- NEW PRODUCT 5
- Parts for Anesthesia 0
- Parts for Camera system 81
- Parts for Defibrillator 0
- Parts for Dynamical System 86
- Parts for Flexible Endoscope 306
- Parts for Microplate Reader 1
- Parts for Monitor 4
- Parts for MRI 0
- Parts for Rigid Endoscope 11
- Parts for Surgical Instrument 46
- Parts for Ultrasound & Probe 87
- Parts for Ventilator 89
- PCR and Centrifuge 8
- Repair Cases 172
- Repair Tools 21
Featured Products
Showing 81–96 of 102 results
Olympus CYF V2 Cystoscope For Repair
$0.00► Brief Description
Fault:Â Leakage.
Solution:
Replace the insert tube, light bundle, biopsy channel, bending section, wire, steel mesh, rubber.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | CYF V2 |
| Fault | Leakage |
| Solution | Replace the insert tube, light bundle, biopsy channel, bending section, wire, steel mesh, rubber |
► Common issues with CYF V2 Cystoscope
- No Image / Dark Image
- Poor Image Resolution / Blurry Image
- Ineffective Suction
- Difficulty with Angulation (Stiff or Loose)
- Bubbles in the Field of View
- Damaged Insertion Tube or Sheath
Olympus ENF-GP fiber nasopharyngeal laryngoscope for repair
$0.00► Brief Description
Fault:
1. Image with black point and image bundle broken
2. Light bundle aged
3. Insert tube aging and wrinkle
4. Bending section deformation
5. Angle with not enough
6. Rubber abrasion
Solution:
Replace image bundle; light bundle; insert tube; wires; helix tube; bending section; rubber
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | ENF-GP |
| Fault | 1. Image with black point and image bundle broken 2. Light bundle aged 3. Insert tube aging and wrinkle 4. Bending section deformation 5. Angle with not enough 6. Rubber abrasion |
| Solution | Replace image bundle; light bundle; insert tube; wires; helix tube; bending section; rubber |
► Common issues with ENF-GP Endoscope
- Bending Section Issues
- Insertion Tube Damage
- Optical/Image System Problems
- Fluid Leaks
- Light Guide and Illumination Issues
Olympus GIF-1TQ160 gastroscope for repair
$0.00► Brief Description
Fault:
1.With image, but CCD with broken.
2.Light bundle broken completely.
3.Insert tube abrasion.
4. No biopsy tube.
5. No air&water tube, no water supply tube.
6. No bending section assembly.
7. No digital tip.
Solution:
Replace CCD, digital tip, light bundle, insert tube,biopsy tube, air&water tube, water supply tube,bending section,wires,helix tube and rubber.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | GIF-1TQ160 |
| Fault | 1.With image, but CCD with broken. 2.Light bundle broken completely. 3.Insert tube abrasion. 4. No biopsy tube. 5. No air&water tube, no water supply tube. 6. No bending section assembly. 7. No digital tip. |
| Solution | Replace CCD, digital tip, light bundle, insert tube,biopsy tube, air&water tube, water supply tube,bending section,wires,helix tube and rubber. |
► Common issues with GIF-1TQ160 gastroscope
- Bending Section and Angulation Issues
- Insertion Tube Damage
- Biopsy/Suction Channel Blockage
- Image Quality Problems
- Air/Water Insufflation Issues
- Fluid Leakage
Olympus GIF-H170 gastroscope for repair
$0.00► Brief Description
Fault:
1. The top left and middle right side with blur image, objective Lens broken.
2. 20% light bundle broken, the small lens turned yellow.
3. Insert tube yellow and wrinkles.
4. The biopsy tube abrasion.
5. The wire and helix tube abrasion.
6. Light guide tube aging and wrinkle.
Solution:
Replace objective lens, light bundle, small lens, insert tube, biopsy tube, wires, helix tube, light guide tube and rubber.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | GIF-H170 |
| Fault | 1. The top left and middle right side with blur image, objective Lens broken. 2. 20% light bundle broken, the small lens turned yellow. 3. Insert tube yellow and wrinkles. 4. The biopsy tube abrasion. 5. The wire and helix tube abrasion. 6. Light guide tube aging and wrinkle. |
| Solution | Replace objective lens, light bundle, small lens, insert tube, biopsy tube, wires, helix tube, light guide tube and rubber. |
► Common issues with GIF-H170 gastroscope
- Insertion Tube Damage
- Light Guide Fiber Breakage
- Image Sensor Failure (CCD/CMOS)
- Angulation Control Issues
- Water/Air Channel Blockage
- Biopsy Channel Blockage or Leakage
- Distal Tip Damage
- Fluid Leakage
Olympus GIF-H180J gastroscope for repair
$0.00► Brief Description
Fault:
1.image with shadow;
2.light bundle broken;
3.insert tube with bite mark;
4.biopsy tube abrasion;
5.bending section serious deformation;
6.wires and helix tube abrasion;
7.light guide tube aging and wrinkle.
Solution:
Replace CCD, light bundle, insert tube,biopsy tube,aire&water tube,bending section,wires,helix tube,light guide tube and rubber.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | GIF-H180J |
| Fault | 1.image with shadow; 2.light bundle broken; 3.insert tube with bite mark; 4.biopsy tube abrasion; 5.bending section serious deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. |
| Solution | Replace CCD, light bundle, insert tube,biopsy tube,aire&water tube,bending section,wires,helix tube,light guide tube and rubber. |
► Common issues with GIF-H180J gastroscope
- Image and Optical Problems
- Bending Section Issues
- Air/Water Channel Problems
- Suction Channel Problems
- External Damage and Wear
Olympus GIF-Q150 Gastroscope for repair
$0.00► Brief Description
Fault:Â
1. With image;
2. Light bundlebreak badlyï¼›
3. Insert tubeaging;
4. Biopsy tubeabrasion, leakage badly;
5. Angle tied, bendingsection, wires and helix tube abrasion;
6. Rubberwithout glue.
Solution:
Replace light bundle, insert tube, biopsy tube, bending section, wires, helixtube and rubber. (No warranty for CCD)
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | GIF-Q150 |
| Fault | 1. With image; 2. Light bundlebreak badlyï¼› 3. Insert tubeaging; 4. Biopsy tubeabrasion, leakage badly; 5. Angle tied, bendingsection, wires and helix tube abrasion; 6. Rubberwithout glue. |
| Solution | Replace light bundle, insert tube, biopsy tube, bending section, wires, helixtube and rubber. (No warranty for CCD) |
► Common issues with GIF-Q150 Gastroscope
- No image/Blackout
- Frozen image
- Poor image quality/Fuzzy image
- Water leakage/Fluid ingress
- Insufficient suction
- Weak air/water flow
- Bending section doesn’t move/Stiff bending section
- Control knobs are loose/No response from control knobs
- Damaged insertion tube
- Damaged light guide
- Stuck elevator mechanism
- Dirty lens
- Error message on processor
Olympus GIF-Q150 gastroscope for repair
$0.00► Brief Description
Fault:
1.with image;
2.one eye of light bundle broken;
3.insert tube little aging;
4.biopsy tube abrasion;
5.bending section deformation;
6.wires and helix tube abrasion;
7.light guide tube aging and wrinkle.
Solution:
Replace light bundle ,insert tube, biopsy tube,bending section,wires,helix tube,light guide tube and rubber.
â–ºProblem & Solutoin
| Brand | OLYMPUS |
| Model | GIF-Q150 |
| Fault | 1.with image; 2.one eye of light bundle broken; 3.insert tube little aging; 4.biopsy tube abrasion; 5.bending section deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. |
| Solution | Replace light bundle ,insert tube, biopsy tube,bending section,wires,helix tube,light guide tube and rubber. |
► Common issues with GIF-Q150 gastroscope
- Bending Section Issues
- Image and Optical Problems
- Air/Water Channel Problems
- Suction Channel Problems
- External Damage and Wear
Olympus GIF-Q180 gastroscope for repair
$0.00► Brief Description
Fault:
1.image definition not enough, CCD aging.
2.30% light bundle broken.
3. Insert tube aging and wrinkle.
4.Biopsy tube abrasion.
5. Bending section bited, transformation.
6. Angle not enough, wires and helix tube abrasion.
7. Light guide tube aging and wrinkle.
8. Pins for wire holder leakage.
Solution:
Replace CCD, light bundle,insert tube, biopsy tube, bending section,helix tube, wires, light guide tube, pins and rubber.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | GIF-Q180 |
| Fault | 1.image definition not enough, CCD aging. 2.30% light bundle broken. 3. Insert tube aging and wrinkle. 4.Biopsy tube abrasion. 5. Bending section bited, transformation. 6. Angle not enough, wires and helix tube abrasion. 7. Light guide tube aging and wrinkle. 8. Pins for wire holder leakage. |
| Solution | Replace CCD, light bundle,insert tube, biopsy tube, bending section,helix tube, wires, light guide tube, pins and rubber. |
► Common issues with GIF-Q180 gastroscope
- Image and Optical Problems
- Bending Section Issues
- Air/Water Channel Problems
- Suction Channel Problems
- External Damage and Wear
Olympus LTF-160 thoracoscope for repair
$0.00► Brief Description
Fault:
1.with image, but big risk for CCD after leakage.
2. Light bundle broken completely.
3. Insert tube with little scratch.
4. Biopsy tube abrasion and leakage.
5. Wires and helix tube abrasion.
6. Grip broken, leakage.
7. All the buttons failure.
8. Rubber leakage.
9. the whole scope leakage.
Solution:
Replace CCD,light bundle, biopsy tube, wires,helix tube,grip and rubber, repair all the buttons.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | LTF-160 |
| Fault | 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the buttons failure. 8. Rubber leakage. 9. the whole scope leakage. |
| Solution | Replace CCD,light bundle, biopsy tube, wires,helix tube,grip and rubber, repair all the buttons. |
► Common issues with LTF-160 thoracoscope
- Image and Optical Problems
- Bending Section and Tip Issues
- Channel Problems (Suction, Biopsy)
- External Damage and Wear
Olympus MAJ-1121 Transducer Handpiece
$0.00► Brief Description
The MAJ-1121 is a dedicated Remote Signal Cable designed for medical endoscopy systems. It serves as the communication bridge between the Olympus Video Processor and peripheral imaging devices.
â–ºFeatures
- Signal Transmission: It relays trigger signals from the remote switches (buttons) located on the endoscope handle to external equipment.
- Workflow Integration:Â Enables the endoscopist to control capturing, printing, or recording without having to touch the peripheral device manually.
- Customizable Mapping:Â Through the Video Processor menu, users can assign different functions (e.g., Freeze, Release, VTR, Print) to specific buttons on the scope handle.
- Plug-and-Play:Â Once the “Remote” port is configured in the system settings, the cable provides an instantaneous response.
- High Reliability:Â Designed with shielding to prevent electromagnetic interference (EMI) from other surgical equipment in the OR or GI suite.
► Specification
| Brand | Olympus |
| Model | MAJ-1121 |
| Condition | Working in Good Condition |
| Series | Transducer Handpiece |
| Compatibility | Olympus CV-140, CV-160, CV-180, and CV-190 Series |
| Standard Length | Approx. 1.8 meters (6 feet) |
| Outer Sheath | Medical-grade PVC (Flexible and durable) |
| Signal Type | Dry contact / Digital TTL trigger signals |
| Connector Type | 14-pin (Round/Circular) Multi-pin Connector |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
OLYMPUS MB-146 SILICONE OIL ENDOSCOPE LUBRICANT
$0.00► Brief Description Â
The MB-146 is a silicone-based lubricant used to ensure the O-rings and detachable parts of Olympus endoscopes remain flexible, create a secure seal, and operate smoothly during clinical use and cleaning/disinfection cycles.
► Features
- Role:Â It is an inert lubricant designed specifically for use with endoscope components.
- Application:Â It is typically applied to the O-rings, valve buttons, and connecting parts (such as those for the water bottle) of endoscopes.
- Benefit:Â Proper lubrication is essential for smooth operation of the endoscope’s controls and for maintaining a proper seal between components, which is critical for the function and water-resistance of the instrument during procedures and reprocessing.
► Specification
| Brand | OLYMPUS |
| Model | MB-146 |
| Condition | Original & new |
| Series | Silicone Oil Lubricant |
| Form | Clear liquid/oil |
| Intended Use | Endoscope Lubrication |
| Packaging | Typically a 15 mL bottle |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
OLYMPUS OTV-S6H-1D Camera Head For Repair
$0.00► Brief Description
Fault:
1.Image yes.
2.Cable aging and interference
Solution:Â Replace new cable.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | OTV-S6H-1D |
| Fault | Cable aging and interference |
| Solution | Replace cable |
► Applications
- Laparoscopy (abdominal surgery)
- Arthroscopy (joint surgery)
- ENT (Ear, Nose, Throat) procedures
- General endoscopic imaging
► Troubleshooting & Support
- Cable connections (damage or loose connections).
- Light source compatibility (requires Olympus or compatible systems).
- Sterilization damage (excessive heat or chemical exposure).
Olympus ShockPULSE-SE Lithotripsy Handpiece SPL-T For Repair
$0.00► Brief Description
Fault:
1.No ultrasonic energy output.
Ultrasonic crystal is damaged.
Solution:Â Replace the ultrasonic crystal.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | SPL-T |
| Ultrasonic crystal | Damaged |
| Fault | No ultrasonic energy output |
| Solution | Replace the ultrasonic crystal |
Olympus SonoSurg-T2H-C Ultrasonic Transducer
$0.00► Brief Description
The SonoSurg-T2H-C is a high-performance handheld transducer (handpiece) that converts electrical energy from the generator into mechanical longitudinal vibrations.
â–ºFeatures
- Energy Conversion:Â Utilizes piezoelectric ceramic elements to generate ultrasonic waves.
- Surgical Action:Â When attached to a compatible probe (scissors or blade), it enables simultaneous cutting and coagulation (hemostasis) of soft tissue using frictional heat.
- Suction Capability:Â Designed with an internal channel to support smoke and fluid evacuation during laparoscopic or open procedures.
► Specification
| Brand | Olympus |
| Model | SonoSurg-T2H-C |
| Condition | Brand new |
| Series | Ultrasonic Transducer |
| Operating Frequency | Approximately 23.5kHz |
| Generator Compatibility | Olympus SonoSurg G2 |
| Vibration Mode | Longitudinal Ultrasonic Vibration |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Olympus TJF-160VR endoscope for repair
$0.00► Brief Description
Fault:
1.No image, CCD broken.
2. Light bundle broken completely.
3. Insert tube aging and wrinkle.
4. Biopsy tube broken.
5. Wires and helix tube broken.
6. clamp wires broken.
7. Operation part broken, no angle.
8. Grip broken.
9. The scope be separated by someone before, some parts missing.
Solution:
Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube, clamp wires,grip,operation part and rubber.
â–ºProblem & Solutoin
| Brand | Olympus |
| Model | TJF-160VR |
| Fault | 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The scope be separated by someone before, some parts missing. |
| Solution | Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube, clamp wires,grip,operation part and rubber. |
► Common issues with TJF-160VR endoscope
- Elevator Mechanism Problems
- Bending Section Issues
- Image and Optical Problems
- Channel Problems (Air, Water, Suction)
- External Damage and Wear
OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR
$0.00► Brief Description
Fault:
1. Image ok;
2. Light bundlestill ok;
3. Insert tubestill ok;
4. Biopsy tubewear;
5. Bendingsection, wires and helix tube wear;
6. Knob leakage.
Solution:
Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD).
â–ºProblem & Solutoin
| Brand | OLYMPUS |
| Model | TJF-Q180V |
| Fault | 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. Bendingsection, wires and helix tube wear; 6. Knob leakage. |
| Solution | Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD) |
► Common issues with TJF-Q180V DUODENOSCOPE
- Fluid Leaks
- Contamination and Foreign Material
- Blocked Channels
- Angulation Wire Damage
- Worn Bending Section
- Forceps Elevator Failure
- Foggy or Blurred Image
- Fiber Optic Damage
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!