Olympus T3110 SonoSurg Scissors for repair

Olympus T3110 SonoSurg Scissors for repair for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!

Olympus TJF-160VR endoscope for repair

$0.00

► Brief Description

Fault:

1.No image, CCD broken.

2. Light bundle broken completely.

3. Insert tube aging and wrinkle.

4. Biopsy tube broken.

5. Wires and helix tube broken.

6. clamp wires broken.

7. Operation part broken, no angle.

8. Grip broken.

9. The scope be separated by someone before, some parts missing.

Solution:

Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube, clamp wires,grip,operation part and rubber.

►Problem & Solutoin

Brand Olympus
Model TJF-160VR
Fault 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The scope be separated by someone before, some parts missing.
Solution Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube, clamp wires,grip,operation part and rubber.

► Common issues with TJF-160VR endoscope

  • Elevator Mechanism Problems
  • Bending Section Issues
  • Image and Optical Problems
  • Channel Problems (Air, Water, Suction)
  • External Damage and Wear

OLYMPUS TJF-160VR endoscope for repair,SN: 250****.

OLYMPUS TJF-160VR endoscope for repair,SN: 250****. for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!

OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR

$0.00

► Brief Description

Fault:

1. Image ok;
2. Light bundlestill ok;
3. Insert tubestill ok;
4. Biopsy tubewear;
5. Bendingsection, wires and helix tube wear;
6. Knob leakage.

Solution:

Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD).

Problem & Solutoin

Brand OLYMPUS
Model TJF-Q180V
Fault 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. Bendingsection, wires and helix tube wear; 6. Knob leakage.
Solution Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD)

► Common issues with TJF-Q180V DUODENOSCOPE

  • Fluid Leaks
  • Contamination and Foreign Material
  • Blocked Channels
  • Angulation Wire Damage
  • Worn Bending Section
  • Forceps Elevator Failure
  • Foggy or Blurred Image
  • Fiber Optic Damage

OLYMPUS TJF-Q180V DUODENOSCOPE SN:270**** FOR REPAIR

OLYMPUS TJF-Q180V DUODENOSCOPE SN:270**** FOR REPAIR for sale, Buy brand new flexible endoscope repair parts for OLYMPUS.Order now!

OLYMPUS TJF-Q180V Electronic Duodenoscope For Repair

► Brief Description

Inspection Results:

1. Image display is available;

2. The light bundle brightness is acceptable;

3. The insertion tube is worn;

4. The light guide tube is worn;

5. The angle is insufficient, the snake bone, steel wire and helix tube are worn;

6. The forceps elevator handle is damaged;

7. The handle shell is severely cracked.

Solution:

Replacement: Insertion tube, handle shell, light guide tube, snake bone, steel wire, helix tube, lifting clamp handle, rubber. CCD is not covered by warranty.

Padgett 3539-252 dermatome handpiece repaired

Padgett 3539-252 dermatome handpiece repaired for sale, Buy brand new flexible endoscope repair parts for Padgett.Order now!

Padgett 3539-252 dermatome Model B host repaired

Padgett 3539-252 dermatome Model B host repaired for sale, Buy brand new flexible endoscope repair parts for Padgett.Order now!

PENTAX Medical EPK-i7000 Video Processor For Repair

$0.00

► Brief Description

  • Brand: PENTAX (PENTAX Endoscope Processor)
    Model: EPK-i7000
    Serial Number: AC***
  • Fault: It cannot recognize the endoscope and reports an error.
  • Solution: Repair the system board.
  • Repair Time: 3-5 working days.
  • Warranty Period: Six months.

►Problem & Solution

Brand PENTAX
Model EPK-i7000
Product Processor
Fault It cannot recognize the endoscope and reports an error.
Solution Repair the system board.

 

► Identify the Exact Issue

  • Symptoms: Does the system fail to power on, overheat, or show errors?
  • Error Codes: Check for any diagnostic LEDs or beep codes.
  • Physical Damage: Inspect for burnt components, blown capacitors, or bent pins

Philips C5-1 convex probe for repair

Philips C5-1 convex probe for repair for sale, Buy brand new flexible endoscope repair parts for Philips.Order now!

Philips C5-1 convex probe for repair

$0.00

► Brief Description

Fault:Lens problem, cable broken, without strain relief.

Solution:Replace probe lens, replace a new cable, replace strain relief.

►Problem & Solutoin

Brand Philips
Model C5-1
Fault Lens problem, cable broken, without strain relief
Solution Replace probe lens, replace a new cable, replace strain relief

► Common issues with C5-1 probe

  • Cable and Connector Damage
  • Acoustic Lens Damage
  • Crystal/Element Failure
  • Intermittent Signal Loss or Noise
  • Housing/Physical Damage

Philips C5-1 convex probe repaired

Philips C5-1 convex probe repaired for sale, Buy brand new flexible endoscope repair parts for Philips.Order now!

Philips C5-2 convex probe for repair

Philips C5-2 convex probe for repair for sale, Buy brand new flexible endoscope repair parts for Philips.Order now!

Philips C5-2 Convex Probe For Repair

$0.00

► Brief Description 

Fault:

Strain relief damage, cable broken.

 

Solution: Replace strain relief, repair cable.

 

►Problem & Solutoin

Brand Philips
Model C5-2 Convex
Fault Strain relief damage, cable broken
Solution Replace strain relief, repair cable

 

► Common Issues with Philips C5-2 Probes

 

  • Dead or flickering elements (image dropouts, black lines)

  • Cable damage (broken wires near the connector or handle)

  • Lens damage (cracks, delamination, or wear)

  • Acoustic array failure (no signal or weak signal)

  • Connector issues (bent pins, corrosion)

► Troubleshooting Steps

 

✅ Check the connector – Ensure no bent pins or debris.
✅ Inspect the cable – Look for cuts, kinks, or internal wire breaks.
✅ Test on another system – Rule out ultrasound machine issues.
✅ Check for physical damage – Cracks in the lens or housing.

Philips EPlQ/X5-1 Probe 2D Image Abnormal For Repair

$0.00

► Brief Description

 

Fault: 2D image abnormal

 

Solution: Replace scanhead

 

►Problem & Solutoin

Brand Philips
Model EPlQ/X5-1
Fault 2D image abnormal
Solution Replace scanhead

 

► Common Problems & Symptoms

 

  • Image Artifacts (black lines, dropouts, flickering) → Damaged elements or cable
  • No Image/Dead Probe → Cable break, connector issues, or internal failure
  • Lens Damage (cracks, delamination) → Acoustic coupling issues
  • Error Messages (“Probe Not Recognized”) → Faulty connector or internal electronics

► Troubleshooting Steps

 

A. Physical Inspection

  • Check for cable damage (kinks, cuts, or fraying near the connector/handle).
  • Inspect the lens for cracks, bubbles, or wear.
  • Examine the connector pins (bent, dirty, or corroded?).

B. Quick Tests

  1. Try the probe on another compatible Philips system (rules out machine issues).
  2. Wiggle the cable while scanning – If image flickers, the cable is likely damaged.
  3. Check for overheating (excessive heat suggests internal failure).

 

Philips EPlQ/X5-1 Probe for repair (SN:B2****£©

Philips EPlQ/X5-1 Probe for repair (SN:B2****£© for sale, Buy brand new flexible endoscope repair parts for Philips.Order now!

Fix Once Right, Save Replacement Costs

Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.

However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.

Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.

If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!