Olympus

Olympus GIF-Q150 gastroscope for repair

$0.00

► Brief Description

Fault:

1.with image;

2.one eye of light bundle broken;

3.insert tube little aging;

4.biopsy tube abrasion;

5.bending section deformation;

6.wires and helix tube abrasion;

7.light guide tube aging and wrinkle.

Solution:

Replace light bundle ,insert tube, biopsy tube,bending section,wires,helix tube,light guide tube and rubber.

â–ºProblem & Solutoin

Brand OLYMPUS
Model GIF-Q150
Fault 1.with image; 2.one eye of light bundle broken; 3.insert tube little aging; 4.biopsy tube abrasion; 5.bending section deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle.
Solution Replace light bundle ,insert tube, biopsy tube,bending section,wires,helix tube,light guide tube and rubber.

► Common issues with GIF-Q150 gastroscope

  • Bending Section Issues
  • Image and Optical Problems
  • Air/Water Channel Problems
  • Suction Channel Problems
  • External Damage and Wear

Olympus GIF-Q180 gastroscope for repair

$0.00

► Brief Description

Fault:

1.image definition not enough, CCD aging.

2.30% light bundle broken.

3. Insert tube aging and wrinkle.

4.Biopsy tube abrasion.

5. Bending section bited, transformation.

6. Angle not enough, wires and helix tube abrasion.

7. Light guide tube aging and wrinkle.

8. Pins for wire holder leakage.

Solution:

Replace CCD, light bundle,insert tube, biopsy tube, bending section,helix tube, wires, light guide tube, pins and rubber.

â–ºProblem & Solutoin

Brand Olympus
Model GIF-Q180
Fault 1.image definition not enough, CCD aging. 2.30% light bundle broken. 3. Insert tube aging and wrinkle. 4.Biopsy tube abrasion. 5. Bending section bited, transformation. 6. Angle not enough, wires and helix tube abrasion. 7. Light guide tube aging and wrinkle. 8. Pins for wire holder leakage.
Solution Replace CCD, light bundle,insert tube, biopsy tube, bending section,helix tube, wires, light guide tube, pins and rubber.

► Common issues with GIF-Q180 gastroscope

  • Image and Optical Problems
  • Bending Section Issues
  • Air/Water Channel Problems
  • Suction Channel Problems
  • External Damage and Wear

Olympus LTF-160 thoracoscope for repair

$0.00

► Brief Description

Fault:

1.with image, but big risk for CCD after leakage.

2. Light bundle broken completely.

3. Insert tube with little scratch.

4. Biopsy tube abrasion and leakage.

5. Wires and helix tube abrasion.

6. Grip broken, leakage.

7. All the buttons failure.

8. Rubber leakage.

9. the whole scope leakage.

Solution:

Replace CCD,light bundle, biopsy tube, wires,helix tube,grip and rubber, repair all the buttons.

â–ºProblem & Solutoin

Brand Olympus
Model LTF-160
Fault 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the buttons failure. 8. Rubber leakage. 9. the whole scope leakage.
Solution Replace CCD,light bundle, biopsy tube, wires,helix tube,grip and rubber, repair all the buttons.

► Common issues with LTF-160 thoracoscope

  • Image and Optical Problems
  • Bending Section and Tip Issues
  • Channel Problems (Suction, Biopsy)
  • External Damage and Wear

Olympus MAJ-1121 Transducer Handpiece

$0.00

► Brief Description

The MAJ-1121 is a dedicated Remote Signal Cable designed for medical endoscopy systems. It serves as the communication bridge between the Olympus Video Processor and peripheral imaging devices.

â–ºFeatures

  • Signal Transmission: It relays trigger signals from the remote switches (buttons) located on the endoscope handle to external equipment.
  • Workflow Integration: Enables the endoscopist to control capturing, printing, or recording without having to touch the peripheral device manually.
  • Customizable Mapping: Through the Video Processor menu, users can assign different functions (e.g., Freeze, Release, VTR, Print) to specific buttons on the scope handle.
  • Plug-and-Play: Once the “Remote” port is configured in the system settings, the cable provides an instantaneous response.
  • High Reliability: Designed with shielding to prevent electromagnetic interference (EMI) from other surgical equipment in the OR or GI suite.

► Specification

Brand Olympus
Model MAJ-1121
Condition Working in Good Condition
Series Transducer Handpiece
Compatibility Olympus CV-140, CV-160, CV-180, and CV-190 Series
Standard Length Approx. 1.8 meters (6 feet)
Outer Sheath Medical-grade PVC (Flexible and durable)
Signal Type Dry contact / Digital TTL trigger signals
Connector Type 14-pin (Round/Circular) Multi-pin Connector
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

OLYMPUS MB-146 SILICONE OIL ENDOSCOPE LUBRICANT

$0.00

► Brief Description  

The MB-146 is a silicone-based lubricant used to ensure the O-rings and detachable parts of Olympus endoscopes remain flexible, create a secure seal, and operate smoothly during clinical use and cleaning/disinfection cycles.

► Features

  • Role: It is an inert lubricant designed specifically for use with endoscope components.
  • Application: It is typically applied to the O-rings, valve buttons, and connecting parts (such as those for the water bottle) of endoscopes.
  • Benefit: Proper lubrication is essential for smooth operation of the endoscope’s controls and for maintaining a proper seal between components, which is critical for the function and water-resistance of the instrument during procedures and reprocessing.

► Specification

Brand OLYMPUS
Model MB-146
Condition Original & new
Series Silicone Oil Lubricant
Form Clear liquid/oil
Intended Use Endoscope Lubrication
Packaging Typically a 15 mL bottle
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

OLYMPUS OTV-S6H-1D Camera Head For Repair

$0.00

► Brief Description

Fault:

1.Image yes.

2.Cable aging and interference

Solution: Replace new cable.

â–ºProblem & Solutoin

Brand Olympus
Model OTV-S6H-1D
Fault Cable aging and interference
Solution Replace cable

► Applications

  • Laparoscopy (abdominal surgery)
  • Arthroscopy (joint surgery)
  • ENT (Ear, Nose, Throat) procedures
  • General endoscopic imaging

► Troubleshooting & Support

  • Cable connections (damage or loose connections).
  • Light source compatibility (requires Olympus or compatible systems).
  • Sterilization damage (excessive heat or chemical exposure).

Olympus ShockPULSE-SE Lithotripsy Handpiece SPL-T For Repair

$0.00

► Brief Description

Fault:

1.No ultrasonic energy output.

Ultrasonic crystal is damaged.

Solution: Replace the ultrasonic crystal.

â–ºProblem & Solutoin

Brand Olympus
Model SPL-T
Ultrasonic crystal Damaged
Fault No ultrasonic energy output
Solution Replace the ultrasonic crystal

Olympus SonoSurg-T2H-C Ultrasonic Transducer

$0.00

► Brief Description

The SonoSurg-T2H-C is a high-performance handheld transducer (handpiece) that converts electrical energy from the generator into mechanical longitudinal vibrations.

â–ºFeatures

  • Energy Conversion: Utilizes piezoelectric ceramic elements to generate ultrasonic waves.
  • Surgical Action: When attached to a compatible probe (scissors or blade), it enables simultaneous cutting and coagulation (hemostasis) of soft tissue using frictional heat.
  • Suction Capability: Designed with an internal channel to support smoke and fluid evacuation during laparoscopic or open procedures.

► Specification

Brand Olympus
Model SonoSurg-T2H-C
Condition Brand new
Series Ultrasonic Transducer
Operating Frequency Approximately 23.5kHz
Generator Compatibility Olympus SonoSurg G2
Vibration Mode Longitudinal Ultrasonic Vibration
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Olympus TJF-160VR endoscope for repair

$0.00

► Brief Description

Fault:

1.No image, CCD broken.

2. Light bundle broken completely.

3. Insert tube aging and wrinkle.

4. Biopsy tube broken.

5. Wires and helix tube broken.

6. clamp wires broken.

7. Operation part broken, no angle.

8. Grip broken.

9. The scope be separated by someone before, some parts missing.

Solution:

Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube, clamp wires,grip,operation part and rubber.

â–ºProblem & Solutoin

Brand Olympus
Model TJF-160VR
Fault 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The scope be separated by someone before, some parts missing.
Solution Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube, clamp wires,grip,operation part and rubber.

► Common issues with TJF-160VR endoscope

  • Elevator Mechanism Problems
  • Bending Section Issues
  • Image and Optical Problems
  • Channel Problems (Air, Water, Suction)
  • External Damage and Wear

OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR

$0.00

► Brief Description

Fault:

1. Image ok;
2. Light bundlestill ok;
3. Insert tubestill ok;
4. Biopsy tubewear;
5. Bendingsection, wires and helix tube wear;
6. Knob leakage.

Solution:

Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD).

â–ºProblem & Solutoin

Brand OLYMPUS
Model TJF-Q180V
Fault 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. Bendingsection, wires and helix tube wear; 6. Knob leakage.
Solution Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD)

► Common issues with TJF-Q180V DUODENOSCOPE

  • Fluid Leaks
  • Contamination and Foreign Material
  • Blocked Channels
  • Angulation Wire Damage
  • Worn Bending Section
  • Forceps Elevator Failure
  • Foggy or Blurred Image
  • Fiber Optic Damage

Original New Olympus MAJ-1500 Waterproof Connector

$0.00

► Brief Description

The Olympus MAJ-1500 is typically a crucial Waterproof Connector (or Pigtail Connector) designed to interface Olympus flexible endoscopes (often the EVIS EXERA III 190 series) with the light source and video processing unit (like the CLV-190 and CV-190).

► Features

  • Video Signal: Transfers the digital image signal from the scope’s CCD/CMOS chip to the CV-190 Video Processor for processing and display.
  • Control Signals: Carries electronic signals related to remote scope controls (e.g., shutter, scope function buttons) back to the processor.
  • Light Transmission: Connects the CLV-190 Light Source’s fiber optic cable to the endoscope’s light guide bundle, ensuring bright, consistent illumination in the patient’s body cavity.
  • Fluid Channeling: Provides sealed pathways for the delivery of air (for insufflation) and water (for lens washing/jet function) from the pump system to the endoscope tip.
  • Reprocessing Interface: It serves as the point where the Leak Tester (like the MB-155 cable) is connected. This allows pressure to be introduced into the scope’s channels before cleaning to verify its waterproof integrity.

► Specification

Brand Olympus
Condition Original & new
Series Waterproof Connector
Model MAJ-1500
Material Durable
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

 

Original New Olympus MH-155 White Balance Cap For Flexible Endoscopes

$0.00

â–º Brief Description

Olympus MH-155 Used to set the accurate white balance for the endoscope’s camera system before a procedure. This ensures that the colors of tissues and organs viewed during endoscopy are displayed correctly on the monitor.

► Features

  • Color Accuracy: Its main purpose is to provide a uniform white reference surface for the endoscope’s video processor. When the scope is aimed at the MH-155 and the white balance function is activated, the system calibrates the video signal, ensuring all other colors (like the red of blood or the pink of tissue) are correctly rendered.
  • Image Optimization: Proper white balance is crucial for high-quality endoscopic imaging, aiding clinicians in accurate diagnosis and identification of pathological changes.

► Specification

Brand Olympus
Model MH-155
Condition Original & new
Primary Function White Balance Adjustment
Product Type Balance Cap
Color White
Reusability Reusable
Compatibility Olympus Endoscopes
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Philips L12-3 linear Probe for repair

$0.00

► Brief Description

Fault: Array element aging, lens bubble.

Solution: Replace Crystal.

â–ºProblem & Solutoin

Brand Philips
Model L12-3
Fault Array element aging, lens bubble
Solution Replace Crystal

► Common issues with L12-3 Probe

  • Image Dropout:
  • Shadows
  • Dual Images
  • Cable Jacket Damage
  • Connector Damage
  • Strain Relief Separation
  • Membrane/Lens Damage

Pre-owend Nozzle For Olympus GIF-H170 Gastroscope

$0.00

â–º Brief Description

For the Olympus GIF-H170 (Optera series) gastroscope, the “nozzle” typically refers to the air/water located at the distal tip of the scope.

► Features

  • Lens Cleaning (Irrigation) :When the air/water valve is fully depressed, the nozzle directs a high-pressure stream of water across the objective lens.
  • Air Insufflation:When the air/water valve hole is covered (without being fully depressed), the nozzle pumps air into the patient’s stomach or esophagus.
  • Maintenance of Field of View:Continuous or intermittent air flow helps prevent the collapse of the organ walls around the distal tip.

â–º Specification

Brand Olympus
Model GIF-H170
Serise Nozzle
Condition Working in Good Condition
Material High-grade medical stainless steel
Tip Diameter 9.2 mm
Nozzle Type Single-nozzle dual-channel
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Water-Resistant Cap MH-553 For Olympus Flexible Video Endoscopes

$0.00

► Brief Description

The Olympus MH-553 is a critical accessory used in medical endoscopy, specifically designed as a Water-Resistant Cap (also known as a Soaking Cap or Leak Test Cap). Its primary purpose is to protect the sensitive electrical connectors of a flexible endoscope during the cleaning, disinfection, and sterilization processes.

► Features

  • Water Ingress Protection
  • Leakage Testing Support
  • Reprocessing Safety
  • Compatibility with ETO Sterilization

► Specification

Brand Olympus
Model MH-553
Condition Original & new
Series Water-Resistant Cap
Compatibility EVIS Series (100, 130, 140, 160, 180, 190, 200, 240, 260)
Device Type Flexible Video Endoscopes
Material Medical-grade high-durability plastic
Attachment Point Electrical connector
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

Fix Once Right, Save Replacement Costs

Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.

However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.

Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.

If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!