Olympus
Product Categories
- NEW PRODUCT 5
- Parts for Anesthesia 0
- Parts for Camera system 81
- Parts for Defibrillator 0
- Parts for Dynamical System 86
- Parts for Flexible Endoscope 306
- Parts for Microplate Reader 1
- Parts for Monitor 4
- Parts for MRI 0
- Parts for Rigid Endoscope 11
- Parts for Surgical Instrument 46
- Parts for Ultrasound & Probe 87
- Parts for Ventilator 89
- PCR and Centrifuge 8
- Repair Cases 172
- Repair Tools 21
Featured Products
Showing 65–80 of 102 results
Light Guide Bundles For Olympus TJF-Q180V Duodenoscope
► Brief Description
The Light Guide Bundle for the Olympus EVIS EXERA II TJF-Q180V Duodenoscope is a core internal component responsible for light transmission. Composed of thousands of high-purity optical glass fibers, this bundle channels high-intensity light from the external medical light source (such as the Olympus CLV-180) through the endoscope’s universal cord and insertion tube, projecting it out via the light guide lenses at the distal end.
Because the TJF-Q180V is widely used for complex Endoscopic Retrograde Cholangiopancreatography (ERCP) procedures, a premium, structurally sound light guide bundle is critical to maintaining optimal visualization and supporting advanced imaging technologies like Narrow Band Imaging (NBI).
► Features
- High-Efficiency Light Transmission: It acts as the primary conduit for light, transferring illumination from the light source connector to the target anatomical site (the duodenum and major duodenal papilla) with minimal optical loss or heat generation.
- Dual-Path Distal Illumination: Because the TJF-Q180V features a side-viewing optical system with dual light guide lenses flanking the objective lens, the bundle bifurcates near the distal tip. This ensures uniform, shadow-reduced illumination across the entire 100°field of view.
- Full Support for Narrow Band Imaging (NBI): It maintains the strict spectral integrity required for NBI. By transmitting specific wavelengths of blue and green light accurately, it allows endoscopists to clearly distinguish mucosal capillaries and tissue structures during ERCP.
- Structural Flexibility and Durability: The bundle is specifically engineered to bend smoothly within the endoscope’s 4-way angulation section (120°Up, 90°Down, 110° Right,90°Left) without snapping individual fiber strands, ensuring a long operational lifespan despite rigorous reprocessing and mechanical maneuvering.
► Specification
| Brand | Olympus |
| Model | TJF-Q180V |
| Condition | Brand new |
| Series | Light Guide Bundles |
| Material Composition | High-transmittance medical-grade optical glass fibers |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Light Guide Lens For Olympus CF-H290I Colonovideoscope
$0.00► Brief Description
For the Olympus CF-H290I (EVIS LUCERA ELITE Colonovideoscope), the Light Guide Lens (LG Lens) is a precision optical component located at the distal tip. It is responsible for the uniform illumination of the colon, working in tandem with the light source and fiber-optic bundles.
► Features
- Uniform Illumination
- Enhanced NBI Transmission
- Thermal Protection
- Hermetic Sealing
► Specification
| Brand | Olympus |
| Model | CF-H290I |
| Condition | Brand new |
| Series | Light Guide Lens |
| Material | High-transmittance Sapphire Glass |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Light Guide Lens For Olympus CF-H290L Colonoscope
$0.00► Brief Description
The Olympus CF-H290L is a high-definition colonoscope. The light guide lenses are critical components located at the distal end (tip) of the scope. Their primary role is to evenly distribute the light transmitted from the light source via fiber-optic bundles to illuminate the colon.
► Features
- Uniform Illumination
- Thermal Protection
- NBI Optimization
- Environmental Sealing
► Specification
| Brand | Olympus |
| Model | CF-H290L |
| Serise | Light Guide Lens |
| Condition | Brand new |
| Material | High-transmittance optical glass |
| Diameter | Typically 1.96 mm to 2.0 mm |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Light Guide Tube For Olympus CF-H290L Video Colonoscope
$0.00► Brief Description
For the Olympus CF-H290L , the “Light Guide Tube” is the section connecting the control body to the light source/processor connector.
► Features
- Light Transmission (Illumination)
- Signal & Data Transfer
- Fluid & Air Management
- Environmental Protection
► Specification
| Brand | Olympus |
| Model | CF-H290L |
| Condition | Brand new |
| Series | Light Guide Tube |
| Length | Approx. 1400 mm to 1500 mm |
| Outer Diameter | Approx. 11.0 mm to 13.0 mm |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Manual Hand Held Leakage Tester For Olympus Endoscope
$0.00► Brief Description
The leak detector is typically used for testing the water resistance and integrity of endoscopes.
► Features
- Pressurization
- Pressure Monitoring/Testing
- Indication/Alert
- Data Management (Automated Models)
► Specification
| Brand | Olympus |
| Condition | Brand new |
| Series | Leakage Tester |
| Compatibility | General |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Objective lens Group for Olympus GIF-H260 gastroscope
$0.00► Brief Description
The objective lens system in the Olympus GIF-H260 gastroscope is a sophisticated optical component located at the very tip of the endoscope. It works in conjunction with the CCD (Charge-Coupled Device) sensor to capture high-quality images of the upper digestive tract.
► Features
- Superior Image Quality
- Extra-Wide Field of View
- Broad Depth of Field
- Spectral Integrity
- Clear View Maintenance
► Specification
| Brand | Olympus |
| Model | GIF-H260 |
| Series | Objective lens |
| Field of View | 140° |
| Depth of Field | 3 – 100 mm |
| Distal End Diameter | 9.8 mm |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Olympus A70940A Autoclavable Arthroscope for repair
$0.00► Brief Description
Fault:
1. Image blur, black dots and dark.
2. Fiber not light enough.
3. Rod lens broken.
4. Objective lens broken and dirty.
Solution:
1. Replace rod lens.
2. Replace inner tube.
3. Replace outer tube.
4. Replace objective lens group.
5. Clean the eyepiece.
6. Replace fiber.
7. Clean and install the optical path, check the image.
8. Seal with endoscope and test.
►Problem & Solutoin
| Brand | Olympus |
| Model | A70940A |
| Fault | 1. Image blur, black dots and dark. 2. Fiber not light enough. 3. Rod lens broken. 4. Objective lens broken and dirty. |
| Solution | 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. |
► Common issues with A70940A Arthroscope
- No image/Blackout
- Dim image/Insufficient light
- Fuzzy/Blurry image
- Deformed image/Shading
- Dust or spots in the image
- Damaged insertion tube
- Fluid ingress
Olympus BF-XP160F Bronchoscope for repair
$0.00► Brief Description
Fault:
1. Image degumming, serious color, CCD aging, a few black and gray spots;
2. 20% of the light bundle is broken;
3. Insert tube aging slightly;
4. Biopsy tube wear, not smooth;
5. Bending section, steel wire, screw tube wear;
Solution:
Replace CCD, image beam, beam, insert tube, pliers tube, snake bone, steel wire, spiral tube, rubber.
►Problem & Solutoin
| Brand | Olympus |
| Model | BF-XP160F |
| Fault | 1. Image degumming, serious color, CCD aging, a few black and gray spots; 2. 20% of the light bundle is broken; 3. Insert tube aging slightly; 4. Biopsy tube wear, not smooth; 5. Bending section, steel wire, screw tube wear; |
| Solution | Replace CCD, image beam, beam, insert tube, pliers tube, snake bone, steel wire, spiral tube, rubber. |
► Common issues with BF-XP160F Bronchoscope
- Bending Section Issues
- Insertion Tube Damage
- Optical/Image System Problems
- Fluid Leaks
- Channel Obstructions
- Light Guide and Illumination Issues
Olympus CCD For CF-H260AI Colonoscope
$0.00► Brief Description
The Olympus CF-H260AI is a high-definition (HDTV) colonoscope from the EVIS EXERA II series. The CCD (Charge-Coupled Device) is the “eye” of the endoscope, located at the distal tip. It is responsible for converting light into electrical signals to produce the video image.
► Features
- HDTV Image Capture
- Narrow Band Imaging (NBI) Support
- Light-to-Signal Conversion
- Color Reproduction and Signal Processing
► Specification
| Brand | Olympus |
| Model | CF-H260AI |
| Condition | Working in Good Condition |
| Series | CCD |
| Sensor Type | High-Definition HDTV CCD |
| Image Resolution | HDTV |
| Field of View (FOV) | 140° (Wide-angle) |
| Depth of Field | 3 mm to 100 mm |
| Aspect Ratio | 4:3 or 16:9 |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
Olympus CF-240AI Colonoscope for repair
$0.00► Brief Description
Fault:
Image blur,insert tube aging,light guide squashed,light guide broken 50%,nozzle blocked,angle tight,forceps channel aging.
Solution:
Replace insertion tube,CCD chips,light guide,forceps channel,water channel,angulation wire,bending mesh,spiral tube,light guide tube,bending rubber.
►Problem & Solutoin
| Brand | Olympus |
| Model | CF-240AI |
| Fault | Image blur,insert tube aging,light guide squashed,light guide broken 50%,nozzle blocked,angle tight,forceps channel aging. |
| Solution | Replace insertion tube,CCD chips,light guide,forceps channel,water channel,angulation wire,bending mesh,spiral tube,light guide tube,bending rubber. |
► Common issues with CF-240AI Colonoscope
- Insertion Tube Damage
- Image Quality Issues
- Mechanism Failures
- Connector and Light Source Issues
Olympus CF-240L Colonoscope for repair
$0.00► Brief Description
Fault: Leakage, glass of light bundle blur, rubber leak, angle not enough,image fuzzle,objective lens scratch.
Solution: Replace rubber, objective lens, C cover. Adjust the angle.
►Problem & Solutoin
| Brand | Olympus |
| Model | CF-240L |
| Fault | Leakage, glass of light bundle blur, rubber leak, angle not enough, image fuzzle,objective lens scratch, |
| Solution | Replace rubber, objective lens, C cover. Adjust the angle. |
► Common issues with CF-240L Colonoscope
- Damaged Insertion Tube
- Worn or Damaged Bending Section
- Fuzzy or Blocked Image
- Dark Spots or Broken Pixels
- Poor Light Transmission
- Fluid Leaks
- Blocked Air/Water or Suction Channels
- Connector Damage
Olympus CF-2T160L Colonoscope for repair
$0.00► Brief Description
Fault:
1. With image.
2. 10% light bundle broken.
3. Insert tube is ok.
4. Biopsy tube abrasion.
5. Angle tied, bending section transformation.
6. Wires, helix tube abrasion, no up angle.
Solution:
Replace image bundle; insert tube; biopsy tube; bending mesh and wires; coil pipe; rubber
►Problem & Solutoin
| Brand | Olympus |
| Model | CF-2T160L |
| Fault | 1. With image. 2. 10% light bundle broken. 3. Insert tube is ok. 4. Biopsy tube abrasion. 5. Angle tied, bending section transformation. 6. Wires, helix tube abrasion, no up angle. |
| Solution | Replace wires, helix tube, bending section and rubber. |
► Common issues with CF-2T160L Colonoscope
- Bending Section Issues
- Insertion Tube Damage
- Optical/Image System Problems
- Fluid Leaks
- Channel Obstructions
- Light Guide and Fiber Optic Issues
OLYMPUS CF-H180AL Electronic Colonoscope For Repair
► Brief Description
Inspection Results:
1. The image is dark, and the CCD is aged.
2. One branch of the light beam is disconnected.
3. The insertion tube is aged and wrinkled.
4. The lower angle is malfunctioning, the other angles are tight, and the snake bone is deformed.
5. The light guide tube is slightly wrinkled.
Solution:
Repair and Replacement: CCD, light bundle, insertion tube, biopsy tube, snake bone, steel wire, helix tube, light guide tube, rubber.
Olympus CF-H190L Colonoscope for repair
$0.00► Brief Description
Fault:
1. Image ok;
2. Light bundle still ok;
3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking;
4. Biopsy tube wear;
5. Left Angle failure, bending section, wire and helix tube wear;
6. Soft and hard adjustment wire wear, relatively tight;
7. Rubber leakage.
Solution:
Replace the insertion tube, biopsy tube, bending section, wire, helix tube, soft and hard adjusting wire and rubber. (No warranty for CCD).
►Problem & Solutoin
| Brand | Olympus |
| Model | CF-H190L |
| Fault | 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking; 4. Biopsy tube wear; 5. Left Angle failure, bending section, wire and helix tube wear; 6. Soft and hard adjustment wire wear, relatively tight; 7. Rubber leakage. |
| Solution | Replace the insertion tube, biopsy tube, bending section, wire, helix tube, soft and hard adjusting wire and rubber. (No warranty for CCD) |
► Common issues with CF-H190L Colonoscope
- No Image/Black Screen
- Dim or Uneven Illumination
- Blurry or Out-of-Focus Image
- Stiff or Difficult Angulation
- Leaking or Failed Leak Test
- Abnormal Angulation
- Biopsy Channel Obstruction
- Damaged Bending Rubber
- Buttons Not Responding
- Water or Air Channel Issues
Olympus CF-Q160AL Colonoscope for repair
$0.00► Brief Description
Fault:
1.No image, CCD broken;
2.image broken completely;
3.insert tube aging;
4.biopsy tube abrasion;
5.bending section abrasion;
6.wires and helix tube abrasion;
7.light guide tube aging and wrinkle.
Solution:
Replace CCD, light bundle, insert tube,biopsy tube,aire&water tube,bending section,wires,helix tube,light guide tube,all the fstener part,clamp and rubber.
►Problem & Solutoin
| Brand | Olympus |
| Model |
CF-Q160AL |
| Fault | 1. With image. 2. 10% light bundle broken. 3. Insert tube is ok. 4. Biopsy tube abrasion. 5. Angle tied, bending section transformation. 6. Wires, helix tube abrasion, no up angle. |
| Solution | Replace wires, helix tube, bending section and rubber. |
► Common issues with CF-Q160AL Colonoscope
- Bending Section Issues
- Insertion Tube Damage
- Optical/Image System Problems
- Fluid Leaks
- Channel Obstructions
- Light Guide and Fiber Optic Issues
Olympus CHF-P20Q endoscope for repair
$0.00► Brief Description
Fault:
1.Insert tube cracked;
2.Rubber leakage;
3.Image with black point and cracked;
4.Angulation tight;
5.Biopsy tube aging
Solution:
Replace image bundle; insert tube; biopsy tube; bending mesh and wires; coil pipe; rubber
►Problem & Solutoin
| Brand | Olympus |
| Model | CHF-P20Q |
| Fault | 1.Insert tube cracked; 2.Rubber leakage; 3.Image with black point and cracked; 4.Angulation tight; 5.Biopsy tube aging |
| Solution | Replace image bundle; insert tube; biopsy tube; bending mesh and wires; coil pipe; rubber |
► Common issues with CHF-P20Q endoscope
- Damaged or Punctured Insertion Tube
- Issues with the Bending Section
- Image Quality Problems
- Fluid Leakage
- Blocked Channels
Fix Once Right, Save Replacement Costs
Flexible endoscopes are among the most advanced and most used devices in the healthcare environment. As their use continues to expand, they are a critical component in improving patient surgical outcomes.
However, without the right quality assurance services, they can also present infection risks to customers, leading to significant avoidable service costs over the life of the device.
Long-term replacement or good accessory maintenance is necessary to extend the life of your endoscope equipment, and CareU Tech is committed to reducing service costs and minimizing patient risk so that repaired endoscopes always meet optimal performance standards.
If you have any needs for flexible endoscope accessories, such as insertion tubes, light guides, biopsy channels, air/water channels, flexures and assemblies, flex rubbers and meshes, etc., please contact our sales team and we will be here to meet your needs!